BIJLAGE II
Bijlage 7 behorende bij artikel 5b. van de Regeling veiligheid zeeschepen
LY3 The Large Commercial Yacht Code
Applicable to yachts which are 24 metres and over in load line length, are in commercial
use for sport or pleasure, do not carry cargo and do not carry more than 12 passengers.
TABLE OF CONTENTS
1
|
FOREWORD
|
12
|
2
|
DEFINITIONS
|
14
|
3
|
APPLICATION AND INTERPRETATION
|
20
|
4
|
CONSTRUCTION AND STRENGTH
|
21
|
5
|
WEATHERTIGHT INTEGRITY
|
23
|
6
|
WATER FREEING ARRANGEMENTS
|
27
|
7A
|
MACHINERY – VESSELS OF LESS THAN 500GT
|
28
|
7B
|
MACHINERY – VESSELS OF 500GT AND OVER
|
29
|
8A
|
ELECTRICAL INSTALLATIONS – VESSELS OF LESS THAN 500GT
|
29
|
8B
|
ELECTRICAL INSTALLATIONS – VESSELS OF 500GT AND OVER
|
30
|
9A
|
STEERING GEAR – VESSELS OF LESS THAN 500GT
|
30
|
9B
|
STEERING GEAR – VESSELS OF 500GT AND OVER
|
30
|
10A
|
BILGE PUMPING – VESSELS OF LESS THAN 500GT
|
30
|
10B
|
BILGE PUMPING – VESSELS OF 500GT AND OVER
|
31
|
11
|
STABILITY
|
31
|
12
|
FREEBOARD
|
37
|
13
|
LIFE SAVING APPLIANCES
|
38
|
14
|
FIRE SAFETY
|
42
|
14A
|
STRUCTURAL FIRE PROTECTION – VESSELS OF LESS THAN 500GT
|
44
|
14B
|
STRUCTURAL FIRE PROTECTION – VESSELS OF 500GT AND OVER
|
47
|
15A
|
FIRE APPLIANCES – VESSELS OF LESS THAN 500GT
|
59
|
15B
|
FIRE APPLIANCES – VESSELS OF 500GT AND OVER
|
61
|
16
|
RADIO
|
61
|
17
|
NAVIGATION LIGHTS, SHAPES AND SOUND SIGNALS
|
63
|
18
|
NAVIGATIONAL EQUIPMENT AND VISIBILITY FROM WHEELHOUSE
|
63
|
19
|
MISCELLANEOUS EQUIPMENT
|
65
|
20
|
ANCHORS AND CABLES
|
65
|
21
|
ACCOMMODATION
|
66
|
21A
|
ACCOMMODATION AND RECREATIONAL FACILITIES – VESSELS OF LESS THAN 200GT CONSTRUCTED
ON OR AFTER THE DATE OF ENTRY INTO FORCE OF MLC 2006
|
68
|
21B
|
ACCOMMODATION – VESSELS ≥200GT CONSTRUCTED ON OR AFTER THE DATE OF ENTRY INTO FORCE
OF MLC 2006
|
71
|
22
|
PROTECTION OF PERSONNEL
|
79
|
23
|
MEDICAL STORES
|
80
|
24
|
SHORE-SHIP TRANSFER OF PERSONNEL
|
80
|
25
|
CLEAN SEAS
|
82
|
26
|
MANNING AND PERSONNEL CERTIFICATION
|
82
|
27
|
PASSENGERS
|
86
|
28
|
SURVEY, CERTIFICATION, INSPECTION AND MAINTENANCE
|
87
|
29
|
CREW AGREEMENTS
|
88
|
30
|
SAFETY MANAGEMENT
|
88
|
31
|
INTERNATIONAL SHIP AND PORT FACILITY SECURITY CODE
|
89
|
ANNEX 1
|
MEMBER’S OF THE STEERING COMMITTEE AND WORKING GROUP RESPONSIBLE FOR THE CODE
|
89
|
ANNEX 2
|
SAFETY MANAGEMENT SYSTEM FOR VESSELS UNDER 500GT
|
89
|
ANNEX 3
|
OPEN FLAME GAS INSTALLATIONS
|
91
|
ANNEX 4
|
LIST OF CERTIFICATES TO BE ISSUED
|
93
|
ANNEX 5
|
UNITED KINGDOM NATIONAL ANNEX
|
94
|
ANNEX 6
|
TECHNICAL STANDARDS FOR HELICOPTER LANDING AREAS
|
98
|
ANNEX 7
|
AMENDMENTS TO THE TEXT OF MSN 1792 LY2 EDITION 2
|
98
|
1 FOREWORD
This Code of Practice has been developed jointly by the United Kingdom, its relevant
overseas territories and crown dependencies1, and international industry representatives.
-
1.1 Where ‘Administration’ is used in the Code, it means the Government of the State
whose flag the ship is entitled to fly.
-
1.2 Vessels are required to comply with the various merchant shipping regulations of the
Administration which are relevant to the class of vessel to which they belong. Vessels
in commercial use for sport or pleasure, such as Large Yachts, do not fall naturally
into a single class and, in any case, prescribed merchant ship safety standards may
be incompatible with the safety needs particular to such vessels. Since its original
publication, the Large Yacht Code has made a significant impression on a maritime
sector which previously found great difficulty in embracing conventional regulation.
As a result the Code enjoys both national support and international recognition as
a standard, breaking new ground both in its inception and methodology.
-
1.3 The Code applies to vessels in commercial use for sport or pleasure (being pleasure
vessels ‘engaged in trade’ for the purpose of Article 5 Exceptions – of the International
Convention on Load Lines, 1966 (ICLL)) which are 24 metres in load line length and
over or, if built before 21 July 1968, 150 gross tons and over according to the tonnage
measurement regulations applying at that date and which do not carry cargo and do
not carry more than 12 passengers. Sail training ships are included in this application.
-
1.4 The United Kingdom has notified the International Maritime Organization of the Code
and its application to pleasure vessels engaged in trade as an equivalent arrangement
under the provisions of Article 8 of the International Convention on Load Lines, 1966,
Regulation I-5 of the International Convention on Safety of Life at Sea, and Article
9 of the International Convention on Standards of Training Certification and Watchkeeping
for Seafarers 1978 as amended. Reference can be made to IMO Circular Letter No. 2937,
dated 13 January 2009.
-
1.5 The Code sets required standards of safety and pollution prevention which are appropriate
to the size of the vessel. The standards applied are either set by the relevant international
conventions or equivalent standards where it is not reasonable or practicable to comply.
Provision is made within the Code to add any specific national requirements within
a National Annex.
An Administration may consider a specific alternative equivalent standard to any standard
required by the Code. Applications which justify either an alternative or exemption
from a specific requirement of the Code can be made to the Administration.
-
1.6 The Code has been developed by an industry wide group with the express intention of
setting pollution prevention and safety standards which identify with the specific
needs of vessels in commercial use for sport and pleasure. The Code was reviewed and
revised in 2012 to bring it up to date and reflect the needs of the industry. The
standards adopted are judged to be at least equivalent in their effect to those required
by the international conventions which apply to a particular vesse.
The membership of the industry wide groups that developed and revised the Code are
listed in Annex 1.
-
1.7 Compliance with the standards required by the Code will entitle a vessel to be issued
with the certification required by the international conventions applicable to the
vessel, upon satisfactory completion of the corresponding surveys and inspections.
The certificates demanded by the international conventions which apply to the vessels
covered by the Code are summarised in Section 28.
-
1.8 When equipment manufactured in accordance with a recognised British, European or International
standard is required by the Code, the Administration may accept existing equipment
which can be shown to be of an equivalent standard and which does not increase the
risk to the ship or its crew and passengers. When such equipment is replaced, the
replacement should conform to the standard required by the Code.
-
1.9 For vessels entitled to fly the flag of a Member State of the European Union, the
Commission of the European Communities' general mutual recognition clause should be
accepted. The clause states:
Any requirement for goods or materials to comply with a specified standard should
be satisfied by compliance with:
-
.1 a relevant standard or code of practice of a national standards body or equivalent
body of a Member State of the European Community; or
-
.2 any relevant international standard recognised for use in any Member State of the
European Community; or
-
.3 a relevant specification acknowledged for use as a standard by a public authority
of any Member State of the European Community; or
-
.4 traditional procedures of manufacture of a Member State of the European Community,
and Turkey, where these are the subject of a written technical description sufficiently
detailed to permit assessment of the goods or materials for the use specified; or
-
.5 a specification sufficiently detailed to permit assessment for goods or materials
of an innovative nature (or subject to innovative processes of manufacture such that
they cannot comply with a recognised standard or specification) and which fulfil the
purpose provided by the specified standard;
provided that the proposed standard, code of practice, specification or technical
description provides, in use, equivalent levels of safety, suitability and fitness
for purpose. Due attention should be paid to the requirements of the Marine Equipment
Directive.
-
1.10 It is recognised that the Code may be required to be revised in the light of experience
gained in its application. Section 3.5 makes provision for this.
-
1.11 It is recommended that pleasure vessels comply with the standards of the Code.
2 DEFINITIONS
(Note – where a definition is not contained within this Code, guidance should be taken
from meanings given within the International Conventions)
‘Administration’ with regard to this Code means the Government of the State whose
flag the ship is entitled to fly.
‘Aiming Circle’ (Touchdown/positioning marking) The aiming point for a normal landing,
so designed that the pilot’s seat can be placed directly above it in any direction
with assured main and tail rotor clearances.
‘Approved’ in respect to materials or equipment means approved by the Administration
or approved by an Administration or organisation which is formally recognised by the
Administration.
‘Authorised surveyor’ means a surveyor who by reason of professional qualifications,
practical experience and expertise is authorised by the Administration to carry out
the survey required for the vessel.
‘Aviation Inspection Body’ Body delegated the responsibility of inspecting helicopter
landing areas by the Administration. The verification process will include inspection,
certification and, where necessary, the application of appropriate operational limitations.
‘Buoyant lifeline’ means a line complying with the requirements of the IMO International
Life-Saving Appliances Code.
‘Cargo’ means an item(s) of value that is carried from one place and discharged at
another place and for which either a charge or no charge is made and is not for use
exclusively onboard the vessel.
‘Commercial vessel’ means a vessel which is not a pleasure vessel.
‘Control stations’ are those spaces in which the ship's radio or main navigating equipment
or the emergency source of power are located or where the fire recording or fire control
equipment is centralised.
‘Design Waterline’ Deepest loaded draught.
‘D-Value’ The largest overall dimension of the helicopter when rotors are turning.
This dimension will normally be measured from the most forward position of the main
rotor tip path plane to the most rearward position of the tail rotor tip path plane
(or the most rearward extension of the fuselage in the case of Fenestron or Notar
tails).
‘D-Circle’ A circle, usually imaginary unless the helicopter landing area itself is
circular, the diameter of which is the D-Value of the largest helicopter the landing
area is intended to serve. This will not be the case for landing areas of less than
1D width. For landing areas of less than 1D width, the edges of the imaginary D circle,
may extend beyond the edge of the load bearing area by up to 0.085D on either side
at the mid point.
‘Efficient’ in relation to a fitting, piece of equipment or material means that all
reasonable and practicable measures have been taken to ensure that it is suitable
for the purpose for which it is intended to be used.
‘Embarkation ladder’ means a ladder complying with the requirements of the IMO International
Life-Saving Appliances Code.
‘Emergency source of electrical power’ is a source of electrical power, intended to
supply the emergency switchboard in the event of failure of the supply from the main
source of electrical power.
‘Emergency switchboard’ is a switchboard which in the event of failure of the main
electrical power supply system is directly supplied by the emergency source of electrical
power or the transitional source of emergency power and is intended to distribute
electrical energy to the emergency services.
‘EPIRB’ means a satellite emergency position-indicating radio beacon, being an earth
station in the mobile-satellite service, the emissions of which are intended to facilitate
search and rescue operations, complying with performance standards adopted by the
IMO contained in either Resolution A.810(19) or Resolution A.812(19) and Resolution
A.662(16), or any Resolution amending or replacing these from time to time and which
is considered by the Administration to be relevant, and is capable of:
-
(a) floating free and automatically activating if the ship sinks;
-
(b) being manually activated; and
-
(c) being carried by one person.
‘Existing vessel’ means any vessel, the keel of which was laid or was at a similar
stage of construction prior to the 1st October 2013 or the date of entry into force
of the Maritime Labour Convention 2006 if that be sooner.
‘Float-free launching’ means that method of launching a liferaft whereby the liferaft
is automatically released from a sinking ship and is ready for use, complying with
the requirements of the IMO International Life-Saving Appliances Code.
‘FOD’ Foreign Object Debris.
‘Freeboard’ has the meaning given in annex I of ICLL. The freeboard assigned is the
distance measured vertically downwards amidships from the upper edge of the deck line
to the upper edge of the related load line.
‘Freeboard deck’ has the meaning given in annex I of ICLL. The freeboard deck is normally
the uppermost complete deck exposed to the weather and sea, which has permanent means
of closing all openings in the weather part thereof, and below which all openings
in the sides of the ship are fitted with permanent means of watertight closing.
In a ship having a discontinuous freeboard deck, the lowest line of the exposed deck
and the continuation of that line parallel to the upper part of the deck is taken
as the freeboard deck.
At the option of the owner and subject to the approval of the Administration, a lower
deck may be designated as the freeboard deck provided it is a complete and permanent
deck continuous in a fore and aft direction at least between the machinery space and
peak bulkheads and continuous athwart ships.
When a lower deck is designated as the freeboard deck, that part of the hull which
extends above the freeboard deck is treated as a superstructure so far as concerns
the application of the conditions of assignment and the calculation of freeboard.
It is from this deck that the freeboard is calculated.
‘Garbage’ means all kinds of victual, domestic and operational waste excluding fresh
fish and parts thereof, generated during the normal operation of the vessel and liable
to be disposed of continuously or periodically, except sewage originating from vessels.
‘Hazardous space’ means a space or compartment in which combustible or explosive gases
or vapours are liable to accumulate in dangerous concentrations.
‘ICAO’ International Civil Aviation Organization.
‘ICLL’ means the International Convention on Load Lines, 1966, as amended.
‘IMO’ means the International Maritime Organization, a specialised agency of the United
Nations devoted to maritime affairs.
‘Inflatable lifejacket’ means a lifejacket complying with the requirements of the
IMO International Life-Saving Appliances Code.
‘Jet A1 Fuel’ also known as kerosene. It is used as a fuel for modern jet and turboprop
engines. It consists primarily of hydrocarbon compounds, but other additives are present
to increase safety. International regulations stipulate uniform standards for the
quality and composition of kerosene.
‘Landing Area’ A generic term referring to any area primarily intended for the landing
or take-off of aircraft.
‘Instructions for on-board maintenance’ means the instructions complying with the
requirements of SOLAS III/Part B – Life Saving Appliances and Arrangements, Regulation
36.
‘Launching appliance’ means a provision complying with the requirements of the IMO
International Life-Saving Appliances Code for safely transferring a lifeboat, rescue
boat, or liferaft respectively, from its stowed position to the water and recovery
where applicable.
‘Length’ means 96% of the total length on a waterline of a ship at 85% of the least
moulded depth measured from the top of the keel, or the length from the fore-side
of the stem to the axis of the rudder stock on that waterline, if that be greater.
In ships designed with a rake of keel the waterline on which this is measured should
be parallel to the designed waterline.2
‘Lifeboat’ means a lifeboat complying with the requirements of the IMO International
Life-Saving Appliances Code.
‘Lifebuoy’ means a lifebuoy complying with the requirements of the IMO International
Life-Saving Appliances Code.
‘Lifejacket’ means a lifejacket complying with the requirements of the IMO International
Life-Saving Appliances Cod.
‘Liferaft’ means a liferaft complying with the requirements of the IMO International
Life-Saving Appliances Code.
‘Line throwing appliance’ means an appliance complying with the requirements of the
IMO International Life-Saving Appliances Code.
‘LOS’ Limited Obstacle Sector. The 150° sector within which obstacles may be permitted,
provided the height of the obstacles is limited.
‘Low flame spread’ means that the surface thus described will adequately restrict
the spread of flame, this being determined to the satisfaction of the Administration
by an established procedure.
‘Machinery spaces’ are all machinery spaces of category A and all other spaces containing
propelling machinery, boilers, oil fuel units, steam and internal combustion engines,
generators and major electrical machinery, oil filling stations, refrigerating, stabilizing,
ventilation and air conditioning machinery, and similar spaces, and trunks to such
spaces.
‘Machinery spaces of category A’ are those spaces and trunks to such spaces which
contain:
-
(a) internal combustion machinery used for main propulsion; or
-
(b) internal combustion machinery used for purposes other than main propulsion where such
machinery has in the aggregate a total power output of not less then 375Kw; or
-
(c) any oil-fired boiler or oil fuel unit.
‘Main source of electrical power’ is a source intended to supply electrical power
to the main switchboard for distribution to all services necessary for maintaining
the ship in normal operation and habitable condition.
‘Main switchboard’ is a switchboard which is directly supplied by the main source
of electrical power and is intended to distribute electrical energy to the ship's
services.
‘Main vertical zone’ means those sections into which the hull, superstructure and
deckhouses are divided by A class divisions, the mean length of which on any deck
does not normally exceed 40 metres.
‘MARPOL’ means the International Convention for the Prevention of Pollution from Ships,
1973, as amended.
‘Major conversion’ means a conversion of a vessel:
-
(a) that substantially alters the dimensions of a vessel;
-
(b) which changes the type of the vessel;
-
(c) the intent of which in the opinion of the Administration is substantially to prolong
its life;
-
(d) which otherwise so alters the ship that, if it were a new vessel, it would become
subject to relevant provisions of the present code not applicable to it as an existing
vessel.
‘Maritime & Coastguard Agency’ (MCA) means the Maritime & Coastguard Agency, an executive
agency of the United Kingdom Department for Transport.
‘Merchant Shipping Notice’ (MSN) means a Notice described as such and issued by the
MCA and reference to a specific Merchant Shipping Notice includes reference to any
Merchant Shipping Notice amending or replacing that Notice which is considered by
the Secretary of State to be relevant from time to time and is specified in a Merchant
Shipping Notice.
‘Mile’ means a nautical mile of 1852 metres.
‘Motor vessel’ means a vessel which is described in the register and on the certificate
of registry as such, and which has a sole means of propulsion either one or more power
units.
‘Multihull vessel’ means any vessel which in any normally achievable operating trim
or heel angle, has a rigid hull structure which penetrates the surface of the sea
over more than one separate or discrete area.
‘New vessel’ means a vessel to which this Code applies, the keel of which was laid
or was at a similar stage of construction on or after the 1st October 2013 or the
date of entry into force of the Maritime Labour Convention 2006 if that be sooner.
‘Not readily ignitable’ means that the surface thus described will not continue to
burn for more than 20 seconds after removal of a suitable impinging test flame.
‘Officer’ means
-
(a) any seafarer who is required to be qualified under the International Convention on
Standards of Training, Certification and Watchkeeping for Seafarers, 1978, as amended
(STCW Convention); or
-
(b) any other seafarer considered by the owner/managing agent to be an officer.
‘OFS’ Obstacle-Free Sector. The 210° sector, extending outwards to a distance that
will allow for an unobstructed departure path appropriate to the helicopter that the
landing area is intended to serve, within which no obstacles above helideck level
are permitted.
‘Owner(s)/managing agent(s)’ means the registered owner(s) or the owner(s) or the
managing agent(s) of the registered owner(s) or the owner(s) or owner(s) ipso facto,
as the case may be.
‘Passenger’ means any person carried in a ship except:
-
(a) a person employed or engaged in any capacity on board the ship on the business of
the ship;
-
(b) a person on board the ship either in pursuance of the obligation laid upon the master
to carry shipwrecked, distressed or other persons, or by reason of any circumstances
that neither the master nor the owner nor the charterer (if any) could have prevented;
and
-
(c) a child under one year of age.
‘Passenger ship’ means a ship carrying more than 12 passengers. ‘Person’ means a person
over the age of one year.
‘Pleasure vessel’ means a vessel so defined by the Administration (see National Annex).
‘Position 1’ means upon exposed freeboard and raised quarter decks, and upon exposed
superstructure decks situated forward of a point located a quarter of the ship's length
from the forward perpendicular.
‘Position 2’ means upon exposed superstructure decks situated abaft a quarter of the
ship’s length from the forward perpendicular.
‘Radar transponder’ means a radar transponder for use in survival craft to facilitate
location of survival craft in search and rescue operations.
‘Recess’ means an indentation or depression in a deck and which is surrounded by the
deck and has no boundary common with the shell of the vessel.
‘Rescue boat’ means a boat complying with the requirements of the IMO International
Life-Saving Appliances Code and designed to rescue persons in distress and for marshalling
liferafts.
‘Retro-reflective material’ means a material which reflects in the opposite direction
a beam of light directed on it.
‘Rocket parachute flare’ means a pyrotechnic signal complying with the requirements
of the IMO International Life-Saving Appliances Code.
‘Safe haven’ means a harbour or shelter of any kind which affords entry, subject to
prudence in the weather conditions prevailing, and protection from the force of the
weather.
‘Sailing vessel’ means a vessel designed to carry sail, whether as a sole means of
propulsion or as a supplementary means.
‘Sail training vessel’ means a sailing vessel which, at the time, is being used either:
-
a) to provide instruction in the principles of responsibility, resourcefulness, loyalty
and team endeavour and to advance education in the art of seamanship; or
-
b) to provide instruction in navigation and seamanship for yachtsmen;
‘Seafarer’ means any person who is employed or engaged or works in any capacity on
board a ship. (See National Annex for interpretation)
‘Self-activating smoke signal’ means a signal complying with the requirements of the
IMO International Life-Saving Appliances Code.
‘Self-igniting light’ means a light complying with the requirements of the IMO International
Life-Saving Appliances Code.
‘Short Range Yacht’ means a vessel under 500GT the keel of which was laid or was at
a similar stage of construction prior to the 1st August 2005 or a new vessel constructed
on or after that date under 300GT:
-
• restricted to operating in forecast or actual wind of a maximum Beaufort Force 4,
for a motor yacht, and Beaufort Force 6 for a sailing yacht;
-
• within 60 nautical miles of a safe haven. (The Administration may permit operation
on specified routes up to 90 nautical miles from a safe haven as appropriate).
‘Similar stage of construction’ means at a stage which:
-
(a) construction identifiable with a specific vessel begins; and
-
(b) assembly of that vessel, comprising at least 1% of the estimated mass of all structural
material has commenced.
In the case of vessels constructed of FRP or GRP this will be considered as the date
when more than 5% of the hull resin and reinforcement has been laid.
‘SLA’ Safe Landing Area. The area bounded by the perimeter line and perimeter lighting.
The construction of the OFS and LOS segments (see below) should ensure that the main
rotor will not risk conflict with obstacles when the nose of the helicopter is butted-up
to, but not projecting over, the perimeter line. Thus the pilot, when landing in unusual
circumstances, has confidence that he can touch down provided that all wheels are
within the SLA and the nose of the helicopter is not projecting over the nearest perimeter
line ahead. However, only correct positioning over the aiming circle (see ‘Aiming
Circle’ above) will ensure proper clearance with respect to physical obstacles, provision
of ground effect, and provision of adequate passenger access/egress.
‘SOLAS’ means the International Convention of Safety of Life at Sea, 1974, as amended.
‘SOLAS A pack’ means a liferaft emergency pack complying with the requirements of
the IMO International Life-Saving Appliances Code.
‘SOLAS B pack’ means a liferaft emergency pack complying with the requirements of
the IMO International Life-Saving Appliances Code.
‘Standard fire test’ means a test in which specimens of the relevant bulkheads, decks
or other constructions are exposed in a test furnace by a specified test method in
accordance with the IMO Fire Test Procedures Code.
‘Submersible Craft’ means any description of manned mobile submersible apparatus which
is designed to maintain some or all of its occupants at or near atmospheric pressure
including free, self-propelled, tethered, towed or bottom contact propelled apparatus
and atmospheric diving suits. A diving bell is not a submersible craft for the purposes
of these Regulations; and ‘diving bell’ means any compression chamber which is capable
of being manned and is used or designed for use under the surface of water in supporting
human life being a chamber in which any occupant is or may be subjected to a pressure
of more than 300 millibars above atmospheric pressure during normal operation;
‘Superstructure’ has the meaning given in annex I to ICLL.
‘Survival craft’ means a craft capable of sustaining the lives of persons in distress
from the time of abandoning the ship.
‘Trainee’
A trainee SHOULD:
-
1. Be engaged for the sole purpose of:
-
(a) obtaining instruction in the principles of responsibility, resourcefulness, loyalty
and team endeavour; and/or
-
(b) instruction in navigation and seamanship, marine engineering or other shipboard related
skills.
-
2. Be considered to form part of a ‘trainee voyage crew'; and
-
3. Participate in the operation of the vessel to the best of his or her ability. A trainee
SHOULD NOT:
-
1. be part of the crew for the purpose of safe manning or have any safety critical duties;
-
2. have any employment contract or any employment relationship with the owner or operator
of the vessel;
-
3. receive any remuneration for his/her activities on board;
-
4. be considered to be a seaman or seafarer; and
-
5. be considered as a passenger*.
*Note - the fact that a trainee(s) may contribute towards the cost of their welfare whilst
on board should not imply that they are passengers.
The Minimum age of trainees should be an issue for the National Marine Administration
and requirements should be as indicated in the National Annex.
Training organisations wishing to operate training vessels carrying more than 12 trainees
should comply with the requirements of the National Marine Administration as indicated
in the National Annex.
‘Training manual’ with regard to life-saving appliances means a manual complying with
the requirements of SOLAS III/Part B – Life Saving Appliances and Arrangements, Regulation
35.
‘Training Vessel’ Training Vessel which may be either a sailing or motor vessel, means
a vessel which is operated to provide:
-
a) instruction in the principles of responsibility, resourcefulness, loyalty and team
endeavour; and/or
-
b) instruction in navigation and seamanship, marine engineering or other shipboard related
skills.
The vessel must be properly and safely manned at all times, both at sea and if necessary
in port, by a sufficient number of experienced and competent personnel to ensure that
trainees are adequately supervised giving particular consideration to the number,
age and sex of the trainees.
All training should be properly organised with clearly detailed objectives and outcomes.
‘Two-way VHF radiotelephone set’ means a portable or a fixed VHF installation for
survival craft complying with the performance standards adopted by the IMO contained
in A.762(18) or any Resolution amending or replacing it which is considered by the
Administration to be relevant from time to time.
‘Voyage’ includes an excursion.
‘Watertight’ means capable of preventing the passage of water in any direction.
‘Weather deck’ means the uppermost complete weather tight deck fitted as an integral
part of the vessel's structure and which is exposed to the sea and weather.
‘Weathertight’ has the meaning given in annex I of ICLL. Weathertight means that in
any sea conditions water will not penetrate into the ship.
‘Wheelhouse’ means the control position occupied by the officer of the watch who is
responsible for the safe navigation of the vessel.
‘Window’ means a ship's window, being any window, regardless of shape, suitable for
installation aboard ships.
3 APPLICATION AND INTERPRETATION
3.1 Application
-
3.1.1 The Code applies to a motor or sailing vessel of 24 metres in load line length and
over or, if built before 21 July 1968, which is of 150 tons3 gross tonnage and over and which, at the time, is in commercial use for sport or
pleasure and carries no cargo and no more than 12 passengers. Sail training vessels
are included in this application.
-
3.1.2 The Administration may establish alternative standards for yachts operating under
International Sailing Federation (ISAF) or Union Internationale Motonautique (UIM)
racing rules.
-
3.1.3 Any provision of the Code expressed in the conditional (i.e. ‘should’) shall be a
requirement.
3.2 Area of Operation
-
3.2.1 In general, requirements given within the Code are based on unrestricted geographical
operation outside Polar Regions, however, where considered appropriate, standards
for vessels operating as Short Range Yachts have been included.
-
3.2.2 Yachts which intend to operate in Polar Regions must meet requirements of one of the
recognised Classification Societies listed in the National Annex appropriate to the
intended area of operation. Stability conditions should include those for icing. Reference
to be made to the IMO Guidelines for Polar Regions, Resolution A.1024(26) as amended
or replaced by IMO for yachts intended to operate inside polar regions.
3.3 Equivalent Standards, Exemptions and Existing Vessels
3.3.1 Equivalent standards
Proposals for the application of alternative standards considered to be at least equivalent
to the requirements of the Code should be submitted to the Administration for approval.
Equivalence may be achieved by incorporating increased requirements to balance deficiencies
and thereby achieve the overall safety standard.
3.3.2 Exemptions
Exemptions should be granted only by the Administration.
Applications for exemption should be made to the Administration and be supported by
justification for the exemption.
The granting of exemptions will be limited by the extent to which international conventions
allow and should be regarded as exceptiona
3.3.3 New and Existing vessels
-
3.3.3.1 In the case of an existing vessel which does not comply fully with the Code safety
standards but for which the Code standards are reasonable and practicable, the Administration
should give consideration to a proposal from the owner(s)/managing agent(s) to phase
in requirements within an agreed time scale not exceeding 18 months.
-
3.3.3.2 When an existing vessel does not meet the Code safety standard for a particular feature
and it can be demonstrated that compliance is neither reasonable nor practicable,
proposals for alternative arrangements should be submitted to the Administration for
approval. In considering individual cases, the Administration should take into account
the vessel's service history and any other factors which are judged to be relevant
to the safety standard which can be achieved.
-
3.3.3.3 Generally, repairs, alterations and refurbishments should comply with the standards
applicable to a new vessel.
-
3.3.3.4 Vessels the keels of which were laid or were at a similar stage of construction before
the 1st October 2013 or the date of entry into force of the Maritime Labour Convention
2006 if that be sooner and which have and have been or are currently under survey
to LY1 or LY2 may continue to be considered under the standards in force at the time
of initial survey with the exception of the following which must comply with this
version of the code:
-
(a) Section 13.2.4 Lifejackets;
-
(b) Section 16.3.1 (Radio equipment);
-
(c) Section 18.1.8 Vessels of 300GT and over have LRIT fitted;
-
(d) Section 18.1.9 Vessels of 150GT and over have BNWAS fitted;
-
(e) Section 26 Manning and Personnel Certification;
-
(f) Section 29 Crew Agreements;
-
(g) Section 30.2 Vessels under 500GT, Safety Management;
-
(h) Existing sailing yachts may take advantage of the definition of a ‘Short range yacht’
in this version of the Code.
-
3.3.3.5 All other vessels should be surveyed under this version of the Code.
3.4 Interpretation
Where a question of interpretation of any part of this Code arises which cannot be
resolved by a delegated authority and the owner(s)/managing agent(s) for a vessel,
a decision on the interpretation may be obtained on written application to the Administration.
3.5 Updating the Code
The requirements of the Code will be reviewed and, if necessary revised, by the Administration
in consultation with the working group.
4 CONSTRUCTION AND STRENG
Objective: The purpose of this section is to ensure that all vessels are constructed
to a consistent standard in respect of strength and watertight integrity. New
Vessels are to be built to the requirements of one of the recognised Classification
Societies listed in the National Annex and issued with a commercial Certificate
of Classification. Existing Vessels which do not have a Certificate of Classification
issued by a Classification Society listed in the National Annex should obtain such
a certificate. For vessels under 500GT alternative arrangements for Short Range
operation may be agreed by the Administration. The extent of the watertight bulkheads
defined in Section 4.3 is to ensure that sufficient buoyancy is maintained by the
vessel to meet the damaged stability requirements of Section 11.
|
4.1 General Requirements
-
4.1.1 All vessels should have a freeboard deck.
-
4.1.2 All vessels should be fitted with a weather deck throughout the length of the vessel
and be of adequate strength to withstand the sea and weather conditions likely to
be encountered in the declared area(s) of operation.
-
4.1.3 The declared area(s) of operation and any other conditions which restrict the use
of the vessel at sea should be recorded on the load line certificate issued to the
vessel.
-
4.1.4 The choice of hull construction material affects fire protection requirements, for
which reference should be made to section 14A and 14B.
-
4.1.5 Where a considerable risk of lightning strike is identified vessels should have lightning
strike protection.
4.2 Structural Strength
-
4.2.1 All vessels must be constructed in accordance with the requirements of a recognised
Classification Society listed in the National Annex.
-
4.2.2 Attention should be paid to local or global hull strength requirements for the provision
of ballast.
4.3 Watertight Bulkheads
Section 11 of the Code deals with subdivision and damage stability requirements which
will determine the number and positioning of watertight bulkheads defined below.
4.4 Enclosed Compartments within the Hull and below the Freeboard Deck provided with
Access through Openings in the Hull
-
4.4.1 Compartment(s) below the freeboard deck, provided for recreational purposes, oil fuelling/fresh
water reception or other purposes to do with the business of the vessel and having
access openings in the hull, should be bounded by watertight divisions without any
opening (i.e. doors, manholes, ventilation ducts or any other opening) separating
the compartment(s) from any other compartment below the freeboard deck, unless provided
with sliding watertight doors complying with 4.3.1, or for vessels under 500GT, hinged
doors complying with 4.4.2.
-
4.4.2 For vessels under 500GT, openings from any other compartment below the freeboard deck
may be fitted with hinged watertight doors provided:
-
4.4.3 Openings in the hull should comply with SOLAS regulation II-1/15-1 – External openings
in cargo ships. Provision should be made to ensure that doors may be manually closed
and locked in the event of power or hydraulic failure. Openings are generally to be
fitted with a sill not less than 600mm above the Design Waterline.
-
4.4.3.1 Openings in the hull with a sill height below, or less than 600mm above the Design
Waterline may be specially considered by the Administration. This consideration may
include but is not limited to:
-
.1 doors from the space providing internal access are to have a sill height at least
600mm above the Design Waterline;
-
.2 the effect of flooding on stability is considered;
-
.3 operational controls and limitations on when and where opening may be use.
4.5 Rigging on Sailing Vessels
4.5.1 General
-
4.5.1.1 The condition of the rig should be monitored in accordance with a Maintenance Manual
and a planned maintenance schedule. The schedule should include, in particular, regular
monitoring of all the gear associated with safe work aloft and on the bowsprit (see
22.3).
4.5.2 Masts and Spars and Standing Rigging
-
4.5.2.1 Dimensions and construction materials of masts and spars and dimensions of standing
rigging including connection to chain plates should be in accordance with the requirements
or recommendations of one of the Classification Societies referred to in 4.3.1.1 or
a recognised national or international standard.
-
4.5.2.2 The associated structure for masts and spars (including chainplates, fittings, decks
and floors) should be constructed to effectively carry and transmit the forces involved.
-
4.5.2.3 Compliance with 4.5.2.1 and 4.5.2.2 should be confirmed by a design review and approval
by one of the Classification Societies (e.g. Rig Design Certificate) which is assigned
with the review of the rig.
-
4.5.2.4 The Maintenance Manual provided by the mast manufacturer should be reviewed and approved
by the Classification Society which is assigned to review the rig design.
-
4.5.2.5 A physical survey on the rig stepping procedure and the rig behaviour during sea trials
is to be carried out by or on behalf of the Classification Society that is involved
with the classification of the vessel’s hull.
-
4.5.2.1 Annual surveys on the vessel should include reviewing records and history of rig maintenance
measures against the specifications provided by the maintenance manual.
4.5.3 Rigging Fittings
The strength of all blocks, shackles, rigging screws, cleats and associated fittings
and attachment points should exceed the breaking strain of the associated running
or standing rigging.
4.5.4 Sails
-
4.5.4.1 Adequate means of reefing or shortening sail should be provided.
-
4.5.4.2 Sailing vessels operating as Short Range Yachts need not carry storm canvas.
-
4.5.4.3 All other vessels should either be provided with separate storm sails or have specific
sails designated and constructed to act as storm canvas.
5 WEATHERTIGHT INTEGRI
Objective: This section is intended to outline standards to be achieved for weathertight
integrity. As far as is practicable, the standards of the 1966 ICLL are to be adhered
to. However, due consideration may be given to arrangements that provide an
equivalent level of safety in respect of the risks of down flooding and green sea
loading.
|
Virtual Freeboard Deck
For the purposes of this section only, where actual freeboard to the weather deck
exceeds that required by ICLL 66 by at least one standard superstructure height, openings
on that deck, abaft of the forward quarter, may be assumed to be in position 2. This
is to be taken, unless otherwise stated, as defined in ICLL 66.
For vessels up to 75m load line length, a standard superstructure height is to be
taken as 1.8m. For vessels over 125m load line length, this is to be taken as 2.3m.
Superstructure heights for vessels of intermediate lengths should be obtained by interpolation.
5.1 Hatchways and Skylight Hatches
5.1.1 General Requirements
-
5.1.1.1 All openings leading to spaces below the weather deck not capable of being closed
weathertight, must be enclosed within either an enclosed superstructure or a weathertight
deckhouse of adequate strength meeting with the requirements of the Load Line Assigning
Authority.
-
5.1.1.2 All exposed hatchways which give access from position 1 and position 2 are to be of
substantial weathertight construction and provided with efficient means of closure.
Weathertight hatch covers should be permanently attached to the vessel and provided
with adequate arrangements for securing the hatch closed.
-
5.1.1.3 Hatches which are designated for escape purposes should be provided with covers which
are to be openable from either side and in the direction of escape they are to be
openable without a key. All handles on the inside are to be non removable. An escape
hatch should be readily identified and easy and safe to use, having due regard to
its position.
5.1.2 Hatchways Which are Open at Sea
In general, hatches should be kept closed at sea. However, hatchways which may be
kept open for access at sea are to be as small as practicable (a maximum of 1 square
metre in clear area), and fitted with coamings of at least 300mm in height in positions
1 and 2 Hatchways should be as near to the centreline as practicable, especially on
sailing vessels. Covers of hatchways are to be permanently attached to the hatch coamings
and, where hinged, the hinges are to be located on the forward side.
5.2 Doorways and Companionways
5.2.1 Doorways Located Above the Weather Deck
-
5.2.1.1 External doors in deckhouses and superstructures that give access to spaces below
the weather deck are to be weathertight and door openings should have coaming heights
of at least:
Location
|
Unrestricted Yachts
|
Short Range Yachts
|
A
|
600mm
|
300mm
|
B
|
300mm
|
150mm
|
C
|
150mm
|
75mm
|
Location A The door is in the forward quarter length of the vessel and is used when
the vessel is at sea.
Location B The door is in an exposed forward facing location aft of the forward
quarter length.
Location C The door is in a protected location aft of the forward quarter length,
or an unprotected door on the first tier deck above the weather deck.
-
5.2.1.2 Weathertight doors should be arranged to open outwards and when located in a houseside,
be hinged at the forward edge. Alternative closing arrangements will be considered
providing it can be demonstrated that the efficiency of the closing arrangements and
their ability to prevent the ingress of water will not impair the safety of the vessel.
-
5.2.1.3 An access door leading directly to the engine room from the weather deck should be
fitted with a coaming of height of at least:
Location
|
Unrestricted Yachts
|
Short Range Yachts
|
Position 1
|
600mm
|
450mm
|
Position 2
|
380mm
|
200mm
|
-
5.2.1.4 Coaming height, construction and securing standards for weathertight doors which are
provided for use only when the vessel is in port or at anchor in calm sheltered waters
and are locked closed when the vessel is at sea, may be considered individually.
5.2.2 Companion Hatch Openings
-
5.2.2.1 Companionway hatch openings which give access to spaces below the weather deck should
be fitted with a coaming, the top of which is at least 300mm above the deck, or 150mm
in the case of Short Range Yachts.
-
5.2.2.2 Washboards may be used to close the vertical opening. When washboards are used, they
should be so arranged and fitted that they will not be dislodged readily. Whilst stowed,
provisions are to be made to ensure that they are retained in a secure location.
-
5.2.2.3 The maximum breadth of an opening in a companion hatch should not exceed 1 metre.
5.3 Skylights
-
5.3.1 All skylights should be of efficient weathertight construction and should be located
on or as near to the centreline of the vessel as practicable.
-
5.3.2 If they are of the opening type they should be provided with efficient means whereby
they can be secured in the closed position.
-
5.3.3 Skylights which are designated for escape purposes should be openable from either
side, and in the direction of escape they are to be openable without a key. All handles
on the inside are to be non-removable. An escape skylight should be readily identified
and easy and safe to use, having due regard to its position.
-
5.3.4 The skylight glazing material and its method of securing within the frame should meet
an appropriate national or international standard. Recognised Classification Society
rules for ‘ships’ are considered to meet these requirements. Where a recognised Classification
Society produces alternative rules for ‘pleasure vessels’ or ‘yachts’, these are considered
appropriate for Short Range Yachts.
A minimum of one portable cover for each size of glazed opening should be provided
which can be accessed rapidly and efficiently secured in the event of a breakage of
the skylight.
5.4 Portlights
-
5.4.1 Portlights should be of strength appropriate to location in the vessel and meet an
appropriate national or international standard. Recognised Classification Society
rules for ‘ships’ are considered to meet these requirements. Where a recognised Classification
Society produces alternative rules for ‘pleasure vessels’ or ‘yachts’, these are considered
appropriate for Short Range Yachts. With regard to structural fire protection, the
requirements for the construction of certain portlights should meet the requirements
of Section 14A and 14B.
-
5.4.2 In general, all portlights fitted in locations protecting openings to spaces below
the weather deck or fitted in the hull of the vessel should be provided with a permanently
attached deadlight which is to be capable of securing the opening watertight in the
event of a breakage of the portlight glazing. Proposals to fit portable deadlights
will be subject to special consideration and approval by the Administration, having
regard for the location of the portlights and the ready availability of deadlights.
Consideration should be given to the provision of operational instructions to the
Master as to when deadlights must be applied to portlights.
-
5.4.3 Portlights fitted in the hull of the vessel below the level of the freeboard deck
should be either non-opening or of a non-readily openable type and be in accordance
with a standard recognised by the Administration. The lower edge of the portlights
should be at least 500mm or 2.5% of the breadth of the vessel, whichever is the greater,
above the all-seasons load line assigned to the vessel. Portlights of the non-readily
opening type must be secured closed when the vessel is in navigation and indication
provided on the bridge that they are closed.
-
5.4.4 Proposals to fit large portlights (i.e. greater than 0.16 M2) in the main hull below the level of the freeboard deck will be subject to special
consideration and approval by the Administration, having regard for their location
and strength and their supporting structure and, the availability of strong protective
covers for them. One item of the special consideration should be operational instructions
to the Master as to when the strong protective covers must be fitted.
-
5.3.4 Portlights should not be fitted in the hull in the way of the machinery space.
5.5 Windows
-
5.5.1 Windows should be of strength appropriate to their location in the vessel and meet
the requirements of BSMA 25 or equivalent international standard. Recognised Classification
Society rules for ‘ships’ are considered to meet these requirements.
Where a recognised Classification Society produces alternative rules for ‘pleasure
vessels’ or ‘yachts’, these are considered appropriate for Short Range Yachts. With
regard to structural fire protection, the requirements for the construction of certain
windows should meet the requirements of 14A and 14B.
-
5.5.2 For all vessels where the glazing material, glazing thickness, or fixing of the windows
does not meet the requirements of a recognised standard, windows may be tested, to
the satisfaction of the Administration, at a minimum of 4 times the required design
pressure derived from an appropriate national or international standard. Additionally,
as a minimum, calculated thicknesses should meet Classification Society requirements
for pleasure vessels or yachts. For Short Range Yachts, test pressures may be reduced
to 2.5 times the derived design pressure.
-
5.5.3 When using BSMA 25 or equivalent, the following minimum design heads may be assumed
when determining design head pressure:
First tier unprotected fronts 4.5 + L/100metres
Second tier unprotected fronts 3.5 metres
Elsewhere 1.5 metres
-
5.5.4 In general, windows fitted in superstructures or weathertight deckhouses are to be
substantially framed and efficiently secured to the structure. The glass is to be
of the toughened safety glass type.
-
5.5.5 Where chemically toughened safety glass is used, windows are to be of the laminated
type, the minimum depth of chemical toughening to be 30 microns on exposed faces.
Regular inspections of the windows, with particular reference to the surface condition,
should form part of the operational procedures and annual survey by a Classification
Society.
-
5.5.6 Windows should not be fitted in the main hull below the level of the freeboard deck.
-
5.5.7 For all vessels, other than Short Range Yachts, storm shutters (strong protective
covers with fittings) are required for all windows in the front and sides of first
tier and front windows of the second tier of superstructures or weathertight deckhouses
above the freeboard deck.
-
5.5.7.1 Where windows are of laminated construction and their equivalent toughened safety
glass thickness exceeds the requirements of the applied standard specified in 5.5.1
by a minimum of 30%, storm shutters need not be carried, but a blanking plate(s) is
to be provided (a plate capable of being fixed over a broken window) so that any window
opening may be sealed in the event of glass failure. For windows subject to test in
accordance with 5.5.2 only blanking plates are required.
When storm shutters are interchangeable port and starboard, a minimum of 50% of each
size should be provided.
-
5.5.8 Side and front windows to the navigating position should not be constructed of polarised
or tinted glass. (See Section 18.2.3)
5.6 Ventilators and Exhausts
-
5.6.1 Adequate ventilation is to be provided throughout the vessel. The accommodation is
to be protected from the entry of gas and/or vapour fumes from machinery, exhaust
and fuel systems, where machinery exhaust systems pass though accommodation they should
be fitted in a gas tight trunk or each space should be fitted with a carbon monoxide
detector, having an alarm provided locally and at a continuously manned station.
-
5.6.2 Ventilators are to be of efficient construction and provided with permanently attached
means of weathertight closure. Generally, ventilators serving any space below the
freeboard deck or an enclosed superstructure should have a coaming of minimum height
of:
Location
|
Unrestricted Yachts
|
Short Range Yachts
|
Forward quarter length
|
900mm
|
450mm
|
Elsewhere
|
760mm
|
380mm
|
-
5.6.3 Ventilators should be kept as far inboard as practicable and the height above the
deck of the ventilator opening should be sufficient to prevent the ingress of water
when the vessel heels.
-
5.6.4 The ventilation of spaces such as the machinery space, which must remain open, requires
special attention with regard to the location and height of the ventilation openings
above the deck, taking into account the effect of down flooding angle on stability
standard. (See section 11).
The means of closure of ventilators serving the machinery space should be selected
with regard to the fire protection and extinguishing arrangements provided in the
machinery space.
-
5.6.5 Engine exhaust outlets which penetrate the hull below the freeboard deck should be
provided with means to prevent back flooding into the hull through a damaged exhaust
system. For vessels operating on unrestricted service a positive means of closure
should be provided. The system should be of equivalent construction to the hull on
the outboard side of the closure. For Short Range Yachts, where the fitting of a positive
closure is not practicable, the exhaust should be looped up above the waterline on
the outboard side of the system, to a minimum height of 1000mm, and be of equivalent
construction to the hull.
5.7 Air Pipes
-
5.7.1 Air pipes serving fuel and other tanks should be of efficient construction and provided
with permanently attached means of weathertight closure. Means of closure may be omitted
if it can be shown that the open end of an air pipe is afforded adequate protection
by other structure(s) which will prevent the ingress of water.
-
5.7.2 Where located on the weather deck, air pipes should be kept as far inboard as practicable
and be fitted with a coaming of sufficient height to prevent inadvertent flooding.
Generally, air pipes to tanks should have a minimum coaming height of:
Location
|
Unrestricted Yachts
|
Short Range Yachts
|
On weather deck
|
760mm
|
380mm
|
Elsewhere
|
450mm
|
225mm
|
-
5.7.3 Air pipes to fuel tanks should terminate at a height of not less than 760mm above
either, the top of the filler pipe for a gravity filling tank or, the top of the overflow
tank for a pressure filling tank.
5.8 Scuppers, Sea Inlets and Discharges and Other Hull Penetrations
-
5.8.1 The standards of ICLL should be applied to every discharge led through the shell of
the vessel as far as it is reasonable and practicable to do so, and in any case, all
sea inlet and overboard discharges should be provided with efficient shut-off valves
arranged in positions where they are readily accessible at all times.
-
5.8.2 Underwater lights and associated penetrations fitted in the hull should be approved
by the Classification Society.
5.9 Materials for Valves and Associated Piping
-
5.9.1 Valves which are fitted below the waterline should be of steel, bronze or other material
having a similar resistance to impact, fire and corrosion. Non metallic valves will
not normally be considered equivalent.
-
5.9.2 The associated piping should, in areas as indicated above, be of steel, bronze, copper
or other equivalent material. Non metallic piping will not normally be considered
equivalent.
-
5.9.3 Where the use of plastic piping is proposed, it will be considered and full details
of the type of piping, its intended location, and use, should be submitted for approval;
with regard to watertight integrity, any plastic piping should be above the waterline.
Due regard should be paid to the IMO Fire Test Procedures Code, and 14A.2.3.4 or 14B.2.11.6.
-
5.9.4 The use of flexible piping in any location should be kept to a minimum compatible
with the essential reason for its use. Flexible piping and the means of joining it
to its associated hard piping system should be approved as fit for the purpose.
5.10 General Equivalence
Where vessels cannot fully comply with the requirements of this section, equivalent
arrangements may be considered by the Administration. Such proposals should take into
account the following, although this should not be considered as an exhaustive list:
-
• Openings to be kept closed at sea
-
• Enhanced Bilge Pumping capacity and additional bilge alarms
-
• Compliance with damage stability if not already a requirement (see Section 11)
-
• Provision of dorade boxes or baffle systems to prevent direct ingress of water
-
• Alternative ventilation for use in bad weather
-
• Consideration of downflooding angle and reduced risk of green sea loads,
-
• i.e. protected position
-
• Enhanced survey inspection regime
-
• Operational Limitations
6 WATER FREEING ARRANGEMENTS
Objective: This section provides for consideration of the risks of green water being
shipped aboard and the resulting consequences with respect to the vessels stability
and safety of personnel on deck.
|
6.1 The standards for water freeing arrangements should comply with ICLL as far as
it is reasonable and practicable to do so.
In any case the intention should be to achieve a standard of safety which is at least
equivalent to the standard of ICLL.
Additionally, where a well is created on each side of the vessel between a superstructure
or deckhouse, and the bulwark in way of that superstructure or deck house, the following
formula may be used to determine the required freeing port areas on each side of the
vessel for the well concerned:
FPREQ = 0.28 x Aw/ B
Where;
FPREQ = Freeing port area required
Aw = Area of well in way of superstructure or deckhouse B = Full beam at deck,
On sailing vessels, where the solid bulwark height does not exceed 150mm, specific
freeing ports, as defined above, are not required.
6.2 In individual cases, when the Administration considers that the requirements
of ICLL cannot be met, the Administration may consider and approve alternative arrangements
to achieve adequate safety standards. Freeing arrangements may take account of a reduced
permeability and volume of the well, when compared to a full size well.
For Short Range Yachts it is considered that the requirement for freeing port area
for a forward or after well may be reduced by a form factor equal to the ratio of
(actual area well) divided by (length of well x breadth of well). Dimensions should
be taken at half height of the bulwark. This may be reduced by 50% providing it can
be shown that the intact stability of the yacht remains acceptable if the well is
flooded to any level up to the bulwark height and that area provided will allow the
well to drain in less than 3 minutes.
In considering an individual case, the Administration will take into account the vessels
past performance in service and the declared area(s) of operation and any other conditions
which restrict the use of the vessel at sea which will be recorded on the load line
certificate issued to the vessel. (See section 4.1.3.)
6.3 Recesses
-
6.3.1 Any recess in the weather deck should be of weathertight construction and should be
self draining under all normal conditions of heel and trim of the vessel.
A swimming pool or spa bath, open to the elements, should be treated as a recess.
-
6.3.2 The means of drainage provided should be capable of efficient operation when the vessel
is heeled to an angle of 10° in the case of a motor vessel (see 10A.2), and 30° in
the case of a sailing vessel.
The drainage arrangements should have the capability of draining the recess (when
fully charged with water) within 3 minutes when the vessel is upright and at the load
line draught. Means should be provided to prevent the backflow of sea water into the
recess.
-
6.3.3 When it is not practical to provide drainage which meets the requirements of 6.3.2,
alternative safety measures may be proposed for approval by the Administration. Where
the above requirements for quick drainage cannot be met, the effect on intact and
damage stability should be considered taking into account the mass of water and its
free surface effect.
7A MACHINERY – VESSELS OF LESS THAN 500GT
Objective: This section outlines the minimum requirements for machinery, which
are to be in accordance with the requirements of one of the Classification Societies
defined in the National Annex and should cover the minimum aspects defined below,
even if the machinery is not considered the primary means of propulsion. Existing
Vessels which are not already Classed should be taken into Class, however alternative
arrangements for Short Range operation may be agreed by the Administration.
|
7A.1 General Requirements
-
7A.1.1 The machinery and its installation should, in general, meet with the requirements
of one of the Classification Societies named in the National Annex. The Class Survey
or Notation should include, as a minimum, propulsion and electrical generation machinery
and shafting. For existing and new vessels which operate with periodically unattended
machinery spaces, the machinery and it’s installation should meet the standards of
SOLAS Chapter II-1/Part E – ‘Additional requirements for periodically unattended machinery
spaces, so far as is reasonable and practicable to do so’.
Plastic piping may be accepted where the piping and the arrangements for its use meet
the requirements of the IMO Fire Test Procedures Code.
-
7A.1.2 The requirements for main propulsion are based upon the installation of diesel
powered units. When other types of main propulsion are proposed, the arrangements
and installation should be specially considered. Where gas turbines are to be fitted,
attention should be paid to the guidance contained within the IMO High Speed Craft
Code, and installation is to be to the satisfaction of the Administration.
-
7A.1.3 Notwithstanding the requirements of paragraph 7A.1.1, in a fuel supply system
to an engine unit, where a flexible section of piping is provided, connections should
be of a screw type or equivalent approved type. Flexible pipes should be fire resistant/metal
reinforced. Materials and fittings should be of a suitable recognised national or
international standard.
7A.2 Installation
-
7A.2.1 Notwithstanding the requirements referred to in 7A.1, the machinery, fuel tanks
and associated piping systems and fittings should be of a design and construction
adequate for the service for which they are intended, and should be so installed and
protected as to reduce to a minimum any danger to persons during normal movement about
the vessel, with due regard being made to moving parts, hot surfaces, and other hazards.
-
7A.2.2 Means should be provided to isolate any source of fuel which may feed a fire in an
engine space. A fuel shut-off valve(s) should be provided which is capable of being
closed from a position outside the engine space. The valve(s) should be fitted as
close as possible to the fuel tank(s).
-
7A.2.3 All external high-pressure fuel delivery lines between the high pressure fuel pumps
and fuel nozzles should be protected with a jacketed tubing system capable of containing
fuel resulting from a high-pressure line failure. The jacketed tubing system should
include means for collection of leakage and arrangements should be provided for an
alarm to be given in the event of a fuel line failure.
-
7A.2.4 When a glass fuel level gauge is fitted it should be of the ‘flat glass’ type with
self closing valves between the gauge and the tank.
7B MACHINERY – VESSELS OF 500GT AND OVER
Objective: This section outlines the minimum requirements for machinery, which
are to be in accordance with the requirements of one of the Classification
Societies defined in the National Annex. The Class Notation should cover the
minimum aspects defined within this chapter even if the machinery is not considered
the primary means of propulsion.
|
-
7B.1 For existing and new vessels the machinery and its installation should meet the requirements
of one of the Classification Societies and of SOLAS Chapters II- 1/Part C Machinery
installations and II-1/Part E – Additional requirements for periodically unattended
machinery spaces, so far as is reasonable and practicable to do so.
-
7B.2 In any case the intention should be to achieve a standard of safety which is at least
equivalent to the standard of SOLAS. Equivalence may be achieved by incorporating
increased requirements to balance deficiencies and thereby achieve the required overall
standard.
-
7B.3 Where gas turbines are to be fitted, attention should be paid to the guidance contained
within the IMO High-speed Craft Code, and installation is to be to the satisfaction
of the Administration.
8A ELECTRICAL INSTALLATIONS -VESSELS OF LESS THAN 500GT
Objective: This section outlines the minimum requirements for electrical installations,
which are to be in accordance with the requirements of one of the Classification Societies
defined in the National Annex, and should cover the minimum aspects defined below.
For sailing vessels, this should also cover the elements necessary to ensure
safety of the vessel including control of the sails, where appropriate. Existing
Vessels which are not already Classed should be taken into Class, however
alternative arrangements for Short Range operation may be agreed by the
Administration.
|
8A.1 Installation
-
8A.1.1 Particular attention should be paid to the provision of overload and short circuit
protection of all circuits, except engine starting circuits supplied from batteries.
-
8A.1.2 Electrical devices working in potentially hazardous areas, into which petroleum vapour
or other hydrocarbon gas may leak, should be of a type certified safe for the hazard.
8A.2 Lighting
-
8A.2.1 Lighting circuits, including those for emergency lighting, should be distributed through
the spaces so that a total blackout cannot occur due to failure of a single protective
device.
-
8A.2.2 An emergency source of lighting should be provided which should be independent of
the general lighting system. This source should be sufficient for up to 3 hours duration
and should include navigation light supplies. The lighting is to provide sufficient
lighting for personnel to escape from the accommodation or working spaces to their
muster station, and launch and board survival craft. Additionally, this light, supplemented
by torches, should be sufficient to permit emergency repairs to machinery etc.
8A.3 Batteries
Batteries of a type suitable for marine use and not liable to leakage should be used.
Areas in which batteries are stowed should be provided with appropriate ventilation
to prevent an accumulation of gas which is emitted from batteries of all types.
8A.4 Emergency Power
Emergency power should be readily available to supply the required emergency lighting,
radio installation and navigation aids for a minimum of 3 hours. As a minimum, the
navigation aids to be supplied by emergency power to include GPS, echo sounder and
AIS. The emergency power supply should be adequate to also supply any electrical emergency
equipment fitted, such as fire pumps, bilge pumps, watertight doors, and rescue boat
davit.
The emergency source of power should be independent of the main power supply, external
to the engine room, and with separate distribution.
8B ELECTRICAL INSTALLATIONS – VESSELS OF 500GT AND OVER
Objective: This section outlines the minimum requirements for electrical, installations
which are to be in accordance with the requirements of one of the Classification Societies
defined in the National Annex, and should cover the minimum aspects defined below.
For sailing vessels, this should also cover the elements necessary to ensure safety
of the vessel including control of the sails, where appropriate.
|
-
8B.1 The electrical equipment and it’s installation should meet the standards of
SOLAS Chapter II-1/Part D – Electrical installations and II-1/Part E – Additional
requirements for periodically unattended machinery spaces, where appropriate, so far
as it is reasonable and practicable to do so.
-
8B.2 The emergency generator, if fitted, should be located above the uppermost continuous
deck but may be located below this deck provided it is protected from the effects
of fire and flooding. In all cases, the emergency generator should be separated from
main generators and main switchboard by a division capable of ensuring its continued
operation. The emergency generator should be self contained (independent of a sea
water suction) and readily accessible from the open deck.
-
8B.3 Cables and wiring serving essential or emergency power, lighting, internal communications
or signals should be routed clear of galleys, machinery places of Category A and their
casings, spaces for storage of petrol, and other high risk fire areas.
9A STEERING GEAR – VESSELS OF LESS THAN 500GT
Objective: This section outlines the minimum requirements for electrical, installations
which are to be in accordance with the requirements of one of the Classification Societies
defined in the National Annex, and should cover the minimum aspects defined below.
For sailing vessels, this should also cover the elements necessary to ensure safety
of the vessel including control of the sails, where appropriate.
|
-
9A.1 General Requirements
The steering gear and its installation should, in general, meet with the requirements
of one of the Classification Societies named in the National Annex.
In the event that the above requirements cannot be met on an existing vessel, the
Administration may be requested to consider and approve alternative arrangements to
achieve adequate safety standards.
-
9A.2 Vessels should be provided with means for directional control of adequate strength
and suitable design to enable the heading and direction of travel to be effectively
controlled at all operating speeds. When appropriate to the safe steering of the vessel,
the steering gear should be power operated in accordance with the requirements of
the Administration.
-
9A.3 When the steering gear is fitted with remote control, arrangements should be made
for emergency steering in the event of a failure of such control.
9B STEERING GEAR – VESSELS OF 500GT AND OVER
Objective: This section outlines the minimum requirements for steering gear, which
are to be in accordance with the requirements of a recognised Classification
Society. The Class Notation or Survey should cover the minimum aspects defined
within this chapter. Due regard is to be paid to the requirements for emergency steering.
|
-
9B.1 For existing and new vessels, the steering gear and its installation should meet the
standards of SOLAS Chapter II-1/Part C – Machinery installations, so far as it is
reasonable and practicable to do so.
-
9B.2 In any case, the intention should be to achieve a standard of safety which is at least
equivalent to the standard of SOLAS. Equivalence may be achieved by incorporating
increased requirements to balance deficiencies and thereby achieve the required overall
standard.
10A BILGE PUMPING – VESSELS OF LESS THAN 500GT
Objective: This section outlines the minimum requirements for bilge pumping,
which are to be in accordance with the requirements of a recognised Classification
Society. The Class Notation should cover the minimum aspects defined within this
chapter. The principle objective of this section is that in the event of one compartment
being flooded, which may or not be the engine room, there is an ability to control
any leakage to adjacent compartments.
|
-
10A.1 General Requirements
The bilge pumping equipment and its installation should, in general, meet with the
requirements of a recognised Classification Society. Either the vessel should be in
class or a statement of compliance issued by one of the Societies should be provided
to the Administration.
In the event that the above requirements cannot be met on an existing vessel, the
Administration may be requested to consider alternative arrangements to achieve adequate
safety standards.
-
10A.2 All vessels should be provided with at least two fixed and independently powered
bilge pumps, with suction pipes so arranged that any compartment can be effectively
drained when the vessel is heeled to an angle of 10°. For Short Range Yachts, the
second pump and suction pipes may be portable.
-
10A.3 The location of pumps required by 10A.2, their individual power supplies and controls,
including those for bilge valves should be such that, in the event of any one compartment
being flooded at least one of those pumps is capable of removing water from the flooded
space and adjacent compartments and discharging this via a dedicated discharge overboard.
-
10A.4 Each bilge pump suction line should be fitted with an efficient strum box.
-
10A.5 In the case of a vessel where the propulsion machinery space may be unmanned
at any time, a bilge level alarm should be fitted. The alarm should provide an audible
and visual warning in the Master's cabin and in the wheelhouse. The audible and visual
alarm may be accepted elsewhere if it is considered that such a location may be more
appropriate.
-
10A.6 Pumping and piping arrangements for bilges into which fuel or other oils of similar
or higher fire risk could collect, under either normal or fault conditions, should
be kept clear of accommodation spaces and separate from accommodation bilge systems.
Bilge level alarms meeting the requirements of 10A.5 should be fitted to all such
bilges.
10B BILGE PUMPING – VESSELS OF 500GT AND OVER
Objective: This section outlines the minimum requirements for bilge pumping, which
are to be in accordance with the requirements of one of the Classification
Societies defined in section 3. The Class Notation should cover the minimum aspects
defined within this chapter. The principle objective of this section is that in the
event of one compartment being flooded, which may or not be the engine room, there
is an ability to control any leakage to adjacent compartments.
|
-
10B.1 For all vessels, the bilge pumping and its installation should as a minimum meet the
cargo vessel standards of SOLAS Chapter II-1/Part B – Subdivision and stability Regulation
21.
-
10B.2 In any case, the intention should be to achieve a standard of safety which is at least
equivalent to the standard of SOLAS. Equivalence may be achieved by incorporating
increased requirements to balance deficiencies and thereby achieve the required overall
standard.
-
10B.3 A minimum of two bilge pumps should be provided. The capacity of the pumps and the
size of the bilge main and branches should meet the capacity requirements for passenger
ships contained in SOLAS.
-
10B.4 In addition the minimum requirements for vessels of less than 500GT contained at section
10A, should also be met.
11 STABILITY
11.1 General
-
11.1.1 This section deals with the standards for both intact and damage stability.
-
11.1.2 An intact stability standard proposed for assessment of a vessel type not covered
by the standards defined in the Code should be submitted to the Administration for
approval at the earliest opportunity.
-
11.1.3 If used, permanent ballast should be located in accordance with a plan approved by
the Administration and in a manner that prevents shifting of position. Permanent ballast
should not be removed from the ship or relocated within the ship without the approval
of the Administration. Permanent ballast particulars should be noted in the ship’s
stability booklet. Attention should be paid to local or global hull strength requirements
from the point of view of the fitting of additional ballast.
11.2 Intact Stability Standards
11.2.1 Motor Vessels
11.2.1.1 Monohull Vessels
The curves of statical stability for seagoing conditions should meet the following
criteria:
-
.1 the area under the righting lever curve (GZ curve) should not be less than 0.055 metre-radians
up to 30° angle of heel and not less than 0.09 metre- radians up to 40° angle of heel,
or the angle of downflooding, if this angle is less;
-
.2 the area under the GZ curve between the angles of heel of 30° and 40° or between 30°
and the angle of downflooding if this is less than 40°, should not be less than 0.03
metre-radians;
-
.3 the righting lever (GZ) should be at least 0.20 metres at an angle of heel equal to
or greater than 30°;
-
.4 the maximum GZ should occur at an angle of heel of preferably exceeding 30° but not
less than 25°;
-
.5 after correction for free surface effects, the initial metacentric height (GM) should
not be less than 0.15 metres; and
-
.6 in the event that the vessels intact stability standard fails to comply with the criteria
defined in .1 to .5 the Administration may be consulted for the purpose of specifying
alternative but equivalent criteria.
11.2.1.2 Monohull Vessels Operating as Short Range Yachts
Where Short Range Yachts are unable to meet the criteria above, the following criteria
may be used:
-
.1 the area under the righting lever curve (GZ curve) should not be less than 0.07 metreradians
up to 15° angle of heel, when maximum GZ occurs at 15°, and 0.055 metre-radians up
to 30° angle of heel, when maximum GZ occurs at 30° or above. Where the maximum GZ
occurs at angles of between 15° and 30°, the corresponding area under the GZ curve,
Areq should be taken as follows:-
Areq = 0.055 +0.001(30° -θmax) metre.radians
where θmax is the angle of heel, in degrees, where the GZ curve reaches its maximum;
-
.2 the area under the GZ curve between the angles of heel of 30° and 40° or between 30°
and the angle of downflooding if this is less than 40°, should not be less than 0.03
metre-radians;
-
.3 the righting lever (GZ) should be at least 0.20 metres at an angle of heel equal to
or greater than 30°;
-
.4 the maximum GZ should occur at an angle of heel not less than 15°;
-
.5 after correction for free surface effects, the initial metacentric height (GM) should
not be less than 0.15 metres.
11.2.1.3 Multi-hulls
The curves of statical stability for seagoing conditions should meet the following
criteria:
-
.1 the area under the righting lever curve (GZ curve) should not be less than 0.075 metre-radians
up to an angle of 20° when the maximum righting lever (GZ) occurs at 20° and, not
less than 0.055 metre-radians up to an angle of 30° when the maximum righting lever
(GZ) occurs at 30° or above. When the maximum GZ occurs at angles between 20° and
30° the corresponding area under the GZ curve, Areq should be taken as follows:-
Areq = 0.055 + 0.002(30° -θmax) metre.radians;
where θmax is the angle of heel in degrees where the GZ curve reaches its maximum;
-
.2 the area under the GZ curve between the angles of heel of 30° and 40°, or between
30° and the angle of downflooding if this is less than 40°, should not be less than
0.03 metre-radians;
-
.3 the righting lever (GZ) should be at least 0.20 metres at an angle of heel where it
reaches its maximum;
-
.4 the maximum GZ should occur at an angle of heel not less than 20°;
-
.5 after correction for free surface effects, the initial metacentric height (GM) should
not be less than 0.15 metres; and
-
.6 if the maximum righting lever (GZ) occurs at an angle of less than 20° approval of
the stability should be considered by the Administration as a special case.
11.2.1.4
For the purpose of assessing whether the stability criteria are met, GZ curves should
be produced for the loading conditions applicable to the operation of the vessel.
11.2.1.5 Superstructures
-
11.2.1.5.1 The buoyancy of enclosed superstructures complying with regulation 3(10)(b) of the
ICLL may be taken into account when producing GZ curves.
-
11.2.1.5.2 Superstructures, the doors of which do not comply with the requirements of regulation
12 of ICLL, should not be taken into account.
11.2.1.6 High Speed Vessels
In addition to the criteria above designers and builders should address the following
hazards which are known to affect vessels operating in planing modes or those achieving
relatively high speeds:
-
.1 directional instability, often coupled to roll and pitch instabilities;
-
.2 bow diving of planing vessels due to dynamic loss of longitudinal stability in calm
seas;
-
.3 reduction in transverse stability with increasing speed in monohulls;
-
.4 porpoising of planing monohulls being coupled with pitch and heave oscillations;
-
.5 generation of capsizing moments due to immersion of chines in planing monohulls (chine
tripping).
11.2.2 Sailing Vessels
11.2.2.1 Monohulls
-
.1 Curves of statical stability (GZ curves) for at least the Loaded Departure with 100%
consumables and the Loaded Arrival with 10% consumables should be produced.
-
.2 The GZ curves required by .1 should have a positive range of not less than 90°.For
vessels of more than 45m, a range of less than 90° may be considered but may be subject
to agreed operational criteria.
-
.3 In addition to the requirements of .2, the angle of steady heel should be greater
than 15 degrees (see figure). The angle of steady heel is obtained from the intersection
of a ‘derived wind heeling lever’ curve with the GZ curve required by .1.
Noting that:
WLO= is the magnitude of the actual wind heeling lever at 0° which would cause the
vessel to heel to the 'down flooding angle' θf or 60° whichever is least.
GZf = is the lever of the vessel's GZ at the down flooding angle (θf) or 60° whichever is least.
θd = is the angle at which the 'derived wind heeling' curve intersects the GZ curve.
(If θd is less than 15° the vessel will be considered as having insufficient stability for
the purpose of the Code).
θf = the 'down-flooding angle' is the angle of heel causing immersion of the lower edge
of openings having an aggregate area, in square metres, greater than:-
All regularly used openings for access and for ventilation should be considered when
determining the downflooding angle. No opening regardless of size which may lead to
progressive flooding should be immersed at an angle of heel of less than 40°. Air
pipes to tanks can, however, be disregarded.
If, as a result of immersion of openings in a superstructure, a vessel cannot meet
the required standard, those superstructure openings may be ignored and the openings
in the weather deck used instead to determine θf. In such cases the GZ curve should be derived without the benefit of the buoyancy
of the superstructure.
It might be noted that provided the vessel complies with the requirements of 11.2.2.1.1,
11.2.2.1.2 and 11.2.2.1.3 and is sailed with an angle of heel which is no greater
than the’ derived angle of heel', it should be capable of withstanding a wind gust
equal to 1.4 times the actual wind velocity (i.e. twice the actual wind pressure)
without immersing the’ down-flooding openings', or heeling to an angle greater than
60°.
11.2.2.2 Multi-hulls
-
.1 Curves of statical stability in both roll and pitch should be prepared for at least
the Loaded Arrival with 10% consumables. The VCG should be obtained by one of the
three methods listed below:
-
.1 inclining of complete craft in air on load cells, the VCG being calculated from the
moments generated by the measured forces; or
-
.2 separate determination of weights of hull and rig (comprising masts and all running
and standing rigging), and subsequent calculation assuming that the hull VCG is 75%
of the hull depth above the bottom of the canoe body, and that the VCG of the rig
is at half the length of the mast (or a weighted mean of the lengths of more than
one mast); or
-
.3 a detailed calculation of the weight and CG position of all components of the vessel,
plus a 15% margin of the resulting VCG height above the underside of canoe body.
-
.2 If naval architecture software is used to obtain a curve of pitch restoring moments,
then the trim angle must be found for a series of longitudinal centre of gravity (LCG)
positions forward of that necessary for the Design Waterline. The curve can then be
derived as follows:
GZ in pitch = CG’ x cos (trim angle)
trim angle = tan
where: CG’= shift of
LCG forward of that required for design trim, measured parallel to baseline
TFP= draught at forward perpendicular
TAP= draught at aft perpendicular
LBP= length between perpendiculars
Approximations to maximum roll or pitch moments are not acceptable.
-
.3 Data should be provided to the user showing the maximum advised mean apparent wind
speed appropriate to each combination of sails, such wind speeds being calculated
as the lesser of the following:
or
where
vW = maximum advised apparent wind speed (knots)
LMR = maximum restoring moment in roll (N.m)
LMP = limiting restoring moment in pitch (N.m), defined as the pitch restoring moment
at the least angle of the following:
A’S = area of sails set including mast and boom (square metres)
h = height of combined centre of effort of sails and spars above the waterline φR = heel angle at maximum roll righting moment (in conjunction with LMR)
φP = limiting pitch angle used when calculating LMP (in conjunction with LMP)
AD = plan area of the hulls and deck (square metres)
b = distance from centroid of AD to the centreline of the leeward hull This data should be accompanied by the note:
In following winds, the tabulated safe wind speed for each sail combination should
be reduced by the boat speed.
-
.4 If the maximum safe wind speed under full fore-and-aft sail is less than 27 knots,
it should be demonstrated by calculation using annex D of ISO 12217-2 (2002) that,
when inverted and/or fully flooded, the volume of buoyancy, expressed in cubic metres
(m3 ), in the hull, fittings and
equipment is greater than:
1.2 x (fully loaded mass in tonnes)
thus ensuring that it is sufficient to support the mass of the fully loaded vessel
by a margin. Allowance for trapped bubbles of air (apart from dedicated air tanks
and watertight compartments) should not be included.
-
.5 The maximum safe wind speed with no sails set calculated in accordance with .3 above
should exceed 36 knots. For Short Range Yachts this wind speed should exceed 32 knots.
-
.6 Trimarans used for unrestricted operations should have sidehulls each having a total
buoyant volume of at least 150% of the displacement volume in the fully loaded condition.
-
.7 The stability information booklet should include information and guidance on:
-
.1 the stability hazards to which these craft are vulnerable, including the risk of capsize
in roll and/or pitch;
-
.2 the importance of complying with the maximum advised apparent wind speed information
supplied;
-
.3 the need to reduce the tabulated safe wind speeds by the vessel speed in following
winds;
-
.4 the choice of sails to be set with respect to the prevailing wind strength, relative
wind direction, and sea state;
-
.5 the precautions to be taken when altering course from a following to a beam wind.
-
.8 In vessels required to demonstrate the ability to float after inversion (according
to .3 above), an emergency escape hatch should be fitted to each main inhabited watertight
compartment such that it is above both upright and inverted waterlines.
11.3 Damage Stability
The following requirements are applicable to all vessels, other than those operating
as Short Range Yachts. Whilst Short Range Yachts are not required to meet the damage
stability criteria defined above, ultimate survivability after minor damage or flooding
is recommended.
It should be noted that compliance with the damage stability criteria is not required
for vessels that obtain full compliance with the ICLL conditions of assignment.
-
11.3.1 The watertight bulkheads of the vessel should be so arranged that minor hull damage
that results in the free flooding of any one compartment, will cause the vessel to
float at a waterline which, at any point, is not less than 75mm below the weather
deck, freeboard deck, or bulkhead deck if not concurrent.
-
11.3.2 Minor damage should be assumed to occur anywhere in the length of the vessel, but
not on a watertight bulkhead.
-
11.3.3 Standard permeabilities should be used in this assessment, as follows:
Space
|
Percentage Permeability
|
Stores
|
60
|
Stores but not a substantial quantity thereof
|
95
|
Accommodation
|
95
|
Machinery
|
85
|
-
11.3.4 In the damaged condition, considered in 11.3.1, the residual stability should be such
that any angle of equilibrium does not exceed 7° from the upright, the resulting righting
lever curve has a range to the downflooding angle of at least 15° beyond any angle
of equilibrium, the maximum righting lever within that range is not less than 100mm
and the area under the curve is not less than 0.015 metre radians.
-
11.3.5 A vessel of 85 metres length and above should meet a SOLAS 90 passenger ship one-compartment
standard of subdivision, calculated using the deterministic damage stability methodology.
11.4 Elements of Stability
-
11.4.1 Unless otherwise specified, the lightship weight, vertical centre of gravity (KG)
and longitudinal centre of gravity (LCG) of a vessel should be determined from the
results of an inclining experiment.
-
11.4.2 An inclining experiment should be conducted in accordance with a detailed standard
which is approved by the Administration and, in the presence of an authorised surveyor.
-
11.4.3 The report of the inclining experiment and the lightship particulars derived should
be approved by the Administration prior to its use in stability calculations.
At the discretion of the owner(s)/managing agent(s) and prior to approval of the lightship
particulars by the Administration, a margin for safety may be applied to the lightship
weight and KG calculated after the inclining experiment. Such a margin should be clearly
identified and recorded in the stability booklet.
A formal record should be kept in the stability booklet of alterations or modifications
to the vessel for which the effects on lightship weight and vertical centres of gravity
are offset against the margin.
-
11.4.4 When sister vessels are built at the same shipyard, the Administration may accept
a lightweight check on subsequent vessels to corroborate the results of the inclining
experiment conducted on the lead vessel of the class.
11.5 Stability Documents
-
11.5.1 A vessel should be provided with a stability information booklet for the Master, that
is to be approved by the Administration.
-
11.5.2 The content, form and presentation of information contained in the stability information
booklet should be based on the model booklet for the vessel type (motor or sailing)
published by/for the Administration.
-
11.5.3 A vessel with previously approved stability information which undergoes a major conversion
or alterations should be subjected to a complete reassessment of stability and provided
with newly approved stability information.
A major refit or major alteration is one which results in either a change in the lightship
weight of 2% and above and/or the longitudinal centre of gravity of 1% and above (measured
from the aft perpendicular) and/or the calculated vertical centre of gravity rises
by 0.25% and above (measured from the keel).
Additionally, unless it can be clearly demonstrated that no major change has occurred,
a lightweight check should be carried out at the renewal survey required by 28.4.1.
-
11.5.4 Sailing vessels should have, readily available, a copy of the ‘Curves of Maximum Steady
Heel Angle to Prevent Downflooding in Squalls’, or in the case of a multihull, the
values of maximum advised mean apparent wind speed, for the reference of the watchkeeper.
This should be a direct copy taken from that contained in the approved stability booklet.
-
11.5.5 The overall sail area and spar weights and dimensions should be as documented in the
vessel’s stability information booklet. Any rigging modifications that increase the
overall sail area, or the weight/dimensions of the rig aloft, must be accompanied
by an approved updating of the stability information booklet.
-
11.5.6 For Short Range Yachts, where the damage stability has not been assessed, the following
note should be added to the approved stability booklet;
‘This vessel has not been assessed for damage stability, and therefore might not remain
afloat in the event of damage or flooding.’
12 FREEBOARD
Objective: The purpose of this section is to ensure that all vessels are assigned
a freeboard in accordance with ICLL 1966. This section also outlines the requirements
for draught marks to enable trim to be readily calculated.
|
12.1 General
-
12.1.1 The freeboard for the vessel and its marking should be approved by the Assigning Authority
for the assignment of freeboard and issue of the International Load Line Certificate
(1966).
-
12.1.2 Vessels should comply with ICLL for the assignment of a freeboard mark which corresponds
to the deepest loading condition included in the stability information booklet for
the vessel.
-
12.1.3 The freeboard assigned should be compatible with the strength of hull structure, intact
and damage stability requirements for the vessel, and should ensure that minimum bow
height requirements are met.
-
12.1.4 The Assigning Authority should provide the owner(s)/managing agent(s) of the vessel
with a copy of the particulars of the freeboard assigned and a copy of the record
of particulars relating to the conditions of assignment.
12.2 Freeboard Mark and Loading
-
12.2.1 The freeboard mark applied should be positioned port and starboard at amidships on
the load line length and may be an all-seasons mark. The mark should be a permanent
disc and be of contrasting colour to the hull of the vessel in way of the mark.
-
12.2.2 The fresh water freeboard allowance should be obtained by deducting from the all-seasons
freeboard assigned, the quantity
where:-
∆ = displacement in salt water in tonnes at the all-seasons draught
T = tonnes per centimetres immersion at the all seasons load waterline
Alternatively the deduction may be taken as 1/48th of the all-seasons draught of the
ship at amidships.
-
12.2.3 A vessel should not operate in any condition which will result in its appropriate
freeboard marks being submerged when it is at rest and upright in calm water.
12.3 Datum Draught Marks
-
12.3.1 Datum draught marks should be provided at the bow and stern, port and starboard, and
be adequate for assessing the condition and trim of the vessel. Such draught marks
maybe single datum lines.
-
12.3.2 The marks should be permanent and easily read but need not be of contrasting colour
to the hull. The marks need not indicate more than one draught at each position and
should be above, but within 1000mm, of the deepest load waterline.
-
12.3.3 The draught to which marks relate should be indicated either above the mark on the
hull and/or in the stability information booklet for the vessel. The position of the
marks should be verified at initial placement by the Administration or the vessel’s
Assigning Authority.
13 LIFE-SAVING APPLIANCES
Objective: The purpose of this section is to ensure that all vessels are equipped
with the minimum essential LSA equipment appropriate to yacht operations. The
basic provision is for the principles of SOLAS to be met, however, some sections
have been identified where alternative standards can be accepted, where appropriate.
|
13.1 General Requirements
-
13.1.1 Life-Saving Appliances should be provided in accordance with Table 1 – Life- Saving
Appliances.
-
13.1.2 All equipment fitted should be of a type which has been accepted by the Administration
as complying with IMO Life-Saving Appliances Code and IMO Resolution MSC.81(70).
-
13.1.3 Additional life-saving equipment which is provided should meet the requirements of
13.1.2.
When personal safety equipment is provided for use in water sports activities, arrangements
for its stowage should ensure that it will not be used mistakenly as lifesaving equipment
in an emergency situation.
-
13.1.4 All life-saving equipment carried should be fitted with retro-reflective material
in accordance with the recommendations of IMO Resolution A.658(16) as amended.
-
13.1.5 Liferaft embarkation arrangements should comply with the following:
-
.1 Where the distance between the embarkation deck and the top of the liferaft buoyancy
tube exceeds 1 metre with the vessel in its lightest condition, an embarkation ladder
is to be provided. A means for fastening is to be provided and ladders are to be readily
available for use at all times.
-
.2 Where the distance between the embarkation deck and the top of the liferaft buoyancy
tube exceeds 4.5 metres with the vessel in its lightest condition, davit launched
liferafts and at least one launching appliance for launching are to be provided on
each side of the vessel.
-
13.1.6 Falls for launching devices are to comply with IMO Life-Saving Appliances Code. When
falls are of stainless steel, they should be renewed at intervals not exceeding the
service life recommended by the manufacturer, or where no service life is stated be
treated as galvanised steel falls. Falls of alternative materials may be considered
by the Administration.
-
13.1.7 Every inflatable or rigid inflatable rescue boat, inflatable lifejacket, inflatable
liferaft and hydrostatic release unit other than a disposable hydro static release
unit should be serviced, at intervals not exceeding 12 months unless extended service
intervals have been approved by the Administration; at a manufacturers approved service
station.
-
13.1.8 All repairs and maintenance of permanently inflated rescue boats should be carried
out in accordance with the manufacturers’ instructions; emergency repairs may be carried
out onboard; however, permanent repairs should be effected at an approved servicing
station.
-
13.1.9 Maintenance of equipment should be carried out in accordance with the instructions
for onboard maintenance.
-
13.1.10 The stowage and installation of all life-saving appliances is to be to the satisfaction
of the Administration.
-
13.1.11 All life-saving appliances should be in working order and be ready for immediate use
at the commencement of, and at all times during, the voyage.
-
13.1.12 For a vessel equipped with stabiliser fins or having other projections at the sides
of the hull, special consideration should be given, and provisions made, as necessary
to avoid possible interference with the safe evacuation of the vessel in an emergency.
-
13.1.13 Means should be provided to prevent overboard discharge of water into survival craft.
Table 1 – LIFE-SAVING APPLIANCES
VESSEL SIZE
|
Short Range Yacht
|
≥ 24m
|
≥ 500GT
|
≥ 85m
|
LIFEBOATS
|
(see 13.2.1)
|
–
|
–
|
–
|
YES
|
LIFERAFTS
|
(see 13.2.2)
|
YES
|
YES
|
YES
|
YES
|
MANOVERBOARD RECOVERY SYSTEM (see 13.2.3.3)
|
YES
|
–
|
–
|
–
|
RESCUE BOAT
|
(see 13.2.3)
|
–
|
YES
|
YES
|
YES
|
LIFEJACKETS
|
(see 13.2.4)
|
YES
|
YES
|
YES
|
YES
|
IMMERSION SUITS
|
(see 13.2.5)
|
YES
|
YES
|
YES
|
YES/2/0
|
LIFEBUOYS (TOTAL)
|
4
|
4
|
8
|
8
|
LIFEBUOYS WITH LIGHT AND SMOKE
|
(see 13.2.6.1)
|
2
|
2
|
2
|
2
|
LIFEBUOYS WITH LIGHT
|
–
|
–
|
2
|
2
|
LIFEBUOYS WITH BUOYANT (see 13.2.9.2) LIFELINE
|
2
|
2
|
2
|
2
|
SET OF LINE THROWING APPLIANCES
(4 lines plus 4 charges)
|
1
|
1
|
1
|
1
|
ROCKET PARACHUTE FLARES
|
6
|
6
|
12
|
12
|
TWO-WAY RADIOTELEPHONE SETS
|
2
|
2
|
2
|
3
|
EPIRB
|
(see 13.2.7)
|
1
|
1
|
1
|
1
|
SART
|
(see 13.2.8)
|
1
|
1
|
2
|
2
|
GENERAL ALARM
|
(see 13.2.9)
|
YES
|
YES
|
YES
|
YES
|
LIGHTING
|
(see13.2.10)
|
YES
|
YES
|
YES
|
YES
|
POSTERS AND SIGNS SHOWING SURVIVAL CRAFT AND EQUIPMENT OPERATING INSTRUCTIONS YES
|
YES
|
YES
|
YES
|
YES
|
TRAINING MANUAL
|
YES
|
YES
|
YES
|
YES
|
INSTRUCTIONS FOR ONBOARD MAINTENANCE
|
YES
|
YES
|
YES
|
YES
|
LIFESAVING SIGNALS AND (see 13.2.11) RESCUE POSTER – SOLAS No 1 IN WHEELHOUSE
|
YES
|
YES
|
YES
|
YES
|
13.2 Equipment Carriage Requirements
13.2.1 Lifeboats (Required for vessels over 85m in length)
-
13.2.1.1 When lifeboats are required to be carried their acceptance is conditional upon the
provision of suitable stowage and launching arrangements.
-
13.2.1.2 When lifeboats are provided on each side of the vessel, the lifeboat(s) on each side
should be of capacity to accommodate the total number of persons onboard.
-
13.2.1.3 Alternative arrangements to the carriage of lifeboats may be considered as indicated
below:
-
.1 substitution of lifeboats by liferafts where the vessel complies with a SOLAS 2 compartment
subdivision standard; or
-
.2 substitution of lifeboats by a sufficient number of davit launched liferafts such
that in the event of any one liferaft being lost or rendered unserviceable, sufficient
aggregate capacity remains on either side of the vessel for all persons on board.
Additionally one approved rescue boat should be provided on each side of the vessel.
-
13.2.1.4 A lifeboat will also be acceptable as a rescue boat provided it also meets the requirements
of the IMO Life-Saving Appliances Code as a rescue boat.
13.2.2 Liferafts
-
13.2.2.1 The liferafts carried are to be stowed in GRP containers and must contain the necessary
‘emergency pack’. For Short Range Yachts, or vessels operating within 60 miles from
a safehaven, liferafts provided may be equipped with a ‘SOLAS B PACK’. For all other
vessels, liferafts should be equipped with a ‘SOLAS A PACK’.
-
13.2.2.2 Liferaft approval includes approval of their stowage, launching and float-free arrangements.
-
13.2.2.3 For vessels of less than 85m in length, or those complying with 13.2.1.3, a sufficient
number of liferafts should be provided so that in the event of any one liferaft being
lost or rendered unserviceable, sufficient aggregate capacity remains on either side
of the vessel for all persons on board. This may be achieved by transferring liferafts
from one side to the other. Where liferafts are transferable, this requirement may
be met by the ability of the rafts to be transferred within 5 minutes, as below:-
Liferafts of 6 – 15 persons capacity to be carried by 2 persons Liferafts of more
than 15 persons capacity to be carried by 4 persons.
-
13.2.2.4 When lifeboats are provided in accordance with 13.2.1.2, sufficient liferafts are
to be provided such that in the event of any one lifeboat being lost or rendered unserviceable,
sufficient aggregate liferaft capacity remains on either side of the vessel for all
persons onboard. Where liferafts are transferable, this requirement may be met by
the ability of the rafts to be transferred within 5 minutes, as detailed in 13.2.2.3.
-
13.2.2.5 GRP containers containing liferafts should be stowed on the weather deck or in an
open space and fitted with hydrostatic release units so that the liferafts will float
free of the vessel and automatically inflate.
-
13.2.2.6 Liferafts may form part of an approved Marine Evacuation System (MES). A sufficient
number of systems should be provided, such that in the event of any one entire system
being lost or rendered unserviceable, sufficient aggregate capacity remains on either
side of the vessel for all persons on board.
-
13.2.2.7 For vessels operating with reduced personnel aboard, attention is drawn to the dangers
associated with the use of large capacity liferafts with small numbers of persons
embarked.
13.2.3 Rescue Boats and Recovery of Persons from the Sea
-
13.2.3(a) Means should be provided for the recovery of a person from the sea to the vessel and
it should be assumed that the person is unconscious or unable to assist in the rescue.
This requirement is satisfied by the following sections as appropriate to the size
of the vessel. If an overside boarding ladder or scrambling net is provided the ladder
or net should extend from the weather deck to at least 600mm below the lowest operational
waterline.
-
13.2.3(b) All rescue boats covered within this section are to be equipped to the requirements
of the IMO Lifesaving Appliance Code Ch V/5.1.2. Additionally, rescue boats need not
be capable of being launched from both sides, and means to lower the boat from within
the boat is not required.
-
13.2.3(c) Launching stations should be in such positions as to ensure safe launching having
particular regard to clearance from the propeller and steeply overhanging portions
of the hull and so that, as far as possible, the rescue boat can be launched down
the straight side of the ship whilst maintaining minimum speed to keep a course.
-
13.2.3(d) If stowed forward the launching appliance and rescue boat should be entirely located
in a sheltered position abaft the vertical extension of the aft most portion of the
collision bulkhead.
13.2.3.1 Vessels of 500GT and over
-
13.2.3.1.1 All vessels of 500GT and over should be provided with a rescue boat meeting SOLAS
requirements in all respects, except for the colour where white will also be considered
acceptable.
-
13.2.3.1.1 The launching appliances should comply and be approved in accordance with the IMO
Lifesaving Appliance Code except that when a power operated crane is fitted, it should
be capable of operation either by hand or by an emergency source of power in the event
of a main power failure. The routing of the emergency source of power should be considered
in respect of damaged waterlines and fire.
13.2.3.2 Vessels under 500GT
-
13.2.3.2.1 Vessels under 500GT should be provided with a rescue boat either meeting the requirements
of 13.2.3.1 or the following:
-
13.2.3.2.2 A boat which is not SOLAS approved but which is suitable for rescue purposes. The
boat may be rigid, rigid inflated, or inflated, and should have a capacity for not
less than 4 persons, one of which should be assumed to be lying down. Tubes of rigid
inflatable or inflatable boats should have a minimum of 3 buoyancy compartments. The
boat is to be capable of displaying a highly visible colour. If the equipment as required
is stowed in a grab bag, it may be stowed in the boat or in an easily accessible location
close to the rescue boat.
-
13.2.3.2.3 Launching appliances should be either of an approved type or comply with the following
requirements:
-
13.2.3.2.4 The appliance should be able to launch the boat within 5 minutes. When a power operated
device is fitted, it should be capable of operation either by hand or by an emergency
source of power in the event of a main power failure. The routing of the emergency
source of power should be considered in respect of damaged waterlines and fire.
-
13.2.3.2.5 The launching appliance and its attachments should be constructed to withstand a static
proof load on test of not less than 2.2 times the maximum working load. Acceptable
factors of safety are 6 for wires, hooks and sheaves, and 4.5 for the remainder of
the launching appliance. The appliance and its attachments should also be tested dynamically
to 1.1 times the working load. It should be noted that there is no requirement to
recover the rescue boat provided that the casualty and the boat’s crew can be recovered
on board from the boat in the water.
The design of the falls and winch system should take account of the principles of
IMO Lifesaving Appliances Code Ch VI/6.1.2
-
13.2.3.2.6 Where it is proposed to use the running rigging on sailing vessels, the above requirements
should also be met.
13.2.3.3 Short Range Yachts
-
13.2.3.3.1 Vessels operating as Short Range Yachts should either comply with requirements of
13.2.3.1 or 13.2.3.2, or the following:
-
13.2.3.3.2 The vessel should have sufficient mobility and manoeuvrability in a seaway to enable
persons to be retrieved from the water. For assessing this ability it is not considered
acceptable to retrieve persons over the stern of the vessel or adjacent to the propeller(s).
The recovery location should be visible from the conning position at all times during
the recovery, although this may be achieved by the use of remote controls where necessary.
-
13.2.3.3.3 The vessel should be provided with suitable equipment and/or arrangements to enable
the person(s) to be recovered without further persons entering the water.
13.2.4 Lifejackets
-
13.2.4.1 One adult SOLAS approved lifejacket should be provided for each person onboard plus
spare adult lifejackets sufficient for at least 10% of the total number of persons
onboard or two, whichever is the greater. Each lifejacket should be fitted with a
light and whistle.
-
13.2.4.2 If the adult lifejackets provided are not designed to fit persons weighing up to 140kg
and with a chest girth of up to 1,750 mm, a sufficient number of suitable accessories
as may be required to provide a lifejacket for each such person should be available
on board to allow them to be secured to such persons.
-
13.2.4.3 Included in the above number of lifejackets, there should be at least two SOLAS approved
inflatable lifejackets for use of the crew of any rescue boat or inflatable boat carried
onboard.
-
13.2.4.4 One SOLAS approved child lifejacket or infant lifejacket should be provided for each
child or infant onboard.
13.2.5 Immersion Suits
-
13.2.5.1 One approved immersion suit should be provided for each person onboard, these may
be of the non-insulated type.
-
13.2.5.2 Due consideration should be given to the provision of appropriate immersion/ thermal
protection for children and infants carried on board.
-
13.2.5.3 For cold water areas of operation, the insulated type should be carried. Reference
to Resolution IMO MSC Circular 1046 should be made for assessment of thermal protection.
13.2.6 Lifebuoys
-
13.2.6.1 Lifebuoys port and starboard provided with combined self-igniting light and self-
activating smoke signals should be capable of quick deployment from the navigating
bridge.
-
13.2.6.2 The attached buoyant lifeline required on each of two of the lifebuoys is to have
a minimum length of 30 metres.
-
13.2.6.3 Each lifebuoy should be marked with the vessel’s name and Port of Registry.
13.2.7 EPIRB
An approved EPIRB should be installed in an easily accessible position ready to be
manually released, capable of being placed in a survival craft and floating free if
the vessel sinks. All EPIRBs should be registered with the Administration. EPIRBS
are to be tested annually and serviced at not more than five yearly intervals by an
approved shore based maintainer.
13.2.8 Radar Transponders (SART)
The SART is to be stowed in an easily accessible position so that it can rapidly be
placed in any survival craft. Means should be provided in order that it can be mounted
in the survival craft at a height of at least 1 metre above sea level.
13.2.9 General Alarm
-
13.2.9.1 For a vessel of less than 500GT this alarm may consist of the ship's whistle or siren
providing it can be heard in all parts of the vessel.
-
13.2.9.2 For a vessel of 500GT and above the requirement of 13.2.9.1 is to be supplemented
by an electrically operated bell or Klaxon system, which is to be powered from the
vessel's main supply and also the emergency source of power (see section 8).
-
13.2.9.3 For a vessel of 85m in length and above, in addition to the requirements of 13.2.9.2,
a public address system or other suitable means of communication should be provided.
13.2.10 Lighting
-
13.2.10.1 Alleyways, internal and external stairways, and exits giving access to, and including,
the muster and embarkation stations should be adequately lit. (See also section 8).
-
13.2.10.2 Adequate lighting is to be provided in the vicinity of survival craft, launching appliance(s)
(when provided) and the overside area of sea in way of the launching position(s).
The lighting should be supplied from the emergency source of power.
13.2.11 Life-saving Signals and Rescue Poster
When display space in the wheelhouse is restricted, the 2 sides of a SOLAS No.2 poster
(as contained in liferaft equipment packs) may be displayed in lieu of a SOLAS No.
1 poster.
14 FIRE SAFETY
14.1 Protection of spaces containing vehicles or craft with fuel in their tanks or
lockers storing such fuels
-
14.1.1 Special consideration should be given to safe conditions of carriage of petrol and
other highly flammable liquids either in hand portable containers/tanks or in the
tanks of vehicles (such as personal water craft, motor cars and helicopters) which
may be transported. This is not considered applicable to diesel stowage.
-
14.1.2 The quantity of petrol and/or other highly flammable liquids carried should be kept
to a minimum, generally up to 150 litres maximum. Greater quantities may be specially
considered by the Administration on receipt of a reasoned case made by the master.
-
14.1.3 Containers used for the carriage of flammable liquids should be constructed to a recognised
standard appropriate to the contents and each container clearly marked to indicate
its contents.
-
14.1.4 Small lockers on open deck for the stowage of hand portable containers of petrol should
be located away from high risk areas, have no electrical fittings, and be provided
with the following:
-
1 Natural ventilation openings top and bottom.
-
2 Drainage leading overboard.
-
3 Means of securing the fuel containers.
-
4 A facility to boundary cool the locker.
-
14.1.5 Enclosed spaces, and larger lockers on open deck, designated for the safe carriage
of petrol or similar fuel or vehicles with fuel in their tanks should be fitted with:
-
.1 A manual water spray system giving a coverage of 3.5 ltr/m /minute over the total
area of deck, which may be taken from the fire main with the isolating valve located
outside the garage. An equivalent arrangement may be considered. Adequate provision
should be made for drainage of water introduced to the space. This should not lead
to machinery or other spaces where a source of ignition may exist.
-
.2 A fixed fire detection and fire alarm system complying with the requirements of SOLAS
Chapter II-2/Part A / Fire Safety Systems Code Chapter IX. The system within the space
should also comply with 14.1.5.5.
-
.3 Ducted mechanical exhaust ventilation, which is isolated from other ventilated spaces,
should provide at least 6 air changes per hour (based on the empty space) and for
which reduction of the airflow should be signalled by an audible and visual alarm
on the navigating bridge and at the ‘in port’ control station(s). Exhaust ducting
should be arranged to extract from the area low over the bilge. If the fan motors
are located in the space or in the ventilation duct they should be certified safe
to the correct designation for the flammable vapour/liquid. The ventilation fans should
be of a non-sparking type and the ventilation system should be capable of rapid shut
down and effective closure in event of fire.
-
.4 A suitable gas detection system is to be provided, with audible and visual alarm in
the wheelhouse and where it may always be observed by the crew.
-
.5 All electrical equipment located up to 450mm above the deck should be certified safe
for petrol vapours.
-
.6 Electrical equipment located higher than 450mm above the deck should either:
-
(a) be to [IP55] standard of construction (IEC Publication 529 -
Classification of Degree of protection Provided by Enclosures); or
-
(b) provided with easily accessible means of isolation (on all poles) located outside
the space. These isolators should be grouped together as far as practicable and be
clearly marked. This option should not be used for safety systems such as steering
motors, rudder indicators, etc.
-
.7 Regardless of the height of installation, it is considered that the following equipment
located within the space should be certified safe for the flammable vapours:
-
(a) gas detection system
-
(b) bilge alarm
-
(c) fire detection system
-
(d) at least one light fitting (on a dedicated circuit, possibly emergency)
It should be noted that electrical equipment includes starters, distribution boxes,
etc.
14.2 Miscellaneous
14.2.1 Construction and Arrangement of Saunas
-
14.2.1.1 All boundaries of the sauna should be of ‘A’ class divisions, and may include changing
rooms, showers and toilets. The sauna should be insulated to A-60 for vessels of 500GT
and over, A-30 for vessels under 500GT, and B-15 for Short Range Yachts, against other
spaces except those inside of the perimeter.
-
14.2.1.2 Bathrooms with direct access to saunas may be considered as part of them. In such
cases, the door between sauna and the bathroom need not comply with fire safety requirements.
-
14.2.1.3 Wooden linings on bulkheads and ceilings are permitted. The ceiling above the oven
should be lined with a non-combustible plate with an air gap of at least 30mm. The
distance from the hot surfaces to combustible materials should be at least 500mm or
the combustible materials should be protected (e.g. non- combustible plate with an
air gap of at least 30mm).
-
14.2.1.4 Wooden benches are permitted.
-
14.2.1.5 The sauna door should open outwards by pushing.
-
14.2.1.6 Electrically heated ovens should be provided with a timer.
-
14.2.1.7 All spaces within the perimeter of the sauna are to be protected by a fire detection
and alarm system and an automatic sprinkler system.
14.2.2 Construction and Arrangement of Steam Room
-
14.2.2.1 The perimeter of the steam room may include changing rooms, showers and toilets.
-
14.2.2.2 Bathrooms with direct access to suite may be considered as part of it. In such cases,
the door between suite and the bathroom need not comply with fire safety requirements.
-
14.2.2.3 If a steam generator of more than 5 kW is contained within the perimeter, the suite
boundary should be constructed to an A-0 standard, or B-0 for Short Range Yachts.
If a steam generator of more than 5 kW is not contained within the perimeter the steam
generator should be protected by A-0 standard divisions, or B-0 for Short Range Yachts
and pipes leading to the discharge nozzles should be lagged.
-
14.2.2.4 If a suite arrangement contains a sauna then the requirements contained in 14.2.1
are applicable, regardless of the steam generator location.
-
14.2.2.5 All spaces within the perimeter are to be protected by a fire detection and alarm
system.
14.2.3 Deep Fat Frying Equipment
Attention is drawn to the requirements in SOLAS II-2/10.6.4 for fire extinguishing
systems for deep fat cooking equipment.
For fryers of up to 15 litres cooking oil capacity, the provision of a suitably sized
Class F extinguisher (BS7937:2000) together with manual isolation of the electrical
power supply is acceptable.
14.3 Fire Control Plan(s)
-
14.3.1 A fire control (general arrangement) plan(s) should be permanently exhibited for the
guidance of the Master and crew of the vessel. The content of the plan(s) should adequately
show and describe the principal fire prevention and protection equipment and materials.
As far as practical, symbols used on the plans should comply with a recognised international
standard. The fire control plan may be a combined Fire & Safety Plan, which should
show the positions of stowage of the life-saving and fire appliances.
-
14.3.2 For each deck, the plan(s) should show the position of control stations; sections
of the vessel which are enclosed respectively by ‘A’ class divisions and ‘B’ class
divisions; location of flammable liquid storage (see 14.1.); particulars of and locations
of fire alarms, fire detection systems, sprinkler installations, fixed and portable
fire extinguishing appliances; fireman's outfit(s); means of access and emergency
escapes for compartments and decks; locations and means of control of systems and
openings which should be closed down in a fire emergency.
-
14.3.3 The plan(s) required by 14.3.1 should be kept up to date. Up-dating alterations should
be applied to all copies of the plan(s) without delay. Each plan should include a
list of alterations and the date on which each alteration was applied.
-
14.3.4 A duplicate set of the plan(s) should be permanently stored in a prominently marked
weathertight enclosure readily accessible to assist non-vessel fire- fighting personnel
who may board the vessel in a fire emergency.
-
14.3.5 Instructions valid to the maintenance and operation of all the equipment and installations
onboard for the fighting and containment of fire should be kept in one document holder,
readily available in an accessible location. For yachts over 500GT, a Fire Training
Manual, as required by SOLAS Chapter II-2/15 should be provided.
14A STRUCTURAL FIRE PROTECTION – VESSELS OF LESS THAN 500GT
Objective: The purpose of this section is to ensure a consistent level of structural
fire protection. The section is primarily concerned with protecting high risk
spaces such as the engine room and galley. It also makes provision for restricting
the quantity of combustible materials and sets out the principles for detection of
fire and effective escape.
|
14A.1 General
-
14A.1.1 Terms used in this section should have the same meaning as defined in SOLAS.
Table 14A.1.1 is a guide to the major requirements of this Section. The Table is intended
as a quick reference to the requirements and is not to be used in isolation when designing
the fire safety arrangements.
Table 14A.1.1
Passive fire protection (see 14A.2).
|
Category ‘A’ machinery spaces: ‘A-30’,
(B-15 for short range yachts);
Galleys: B-15 (for yachts not being Short Range Yachts)’.
|
Means of escape (see 14A.3):
• Category ‘A’ machinery spaces.
• Accommodation and other spaces
|
Two (2).
Two (2).
|
Fixed fire detection system (see 14A.7).
|
• Fitted in machinery spaces.
• Fitted in service spaces, control stations and accommodation spaces.
|
Automatic sprinkler system or equivalent
|
Fitted in yachts that do not meet restrictions on combustible materials (14A.2.3.6
& 14A.2.3.8).
|
14A.2 Structure
Purpose
The purpose of this section is to contain a fire in the space of origin. For this
purpose, the following functional requirements should be met:
14A.2.1 Forms of construction – Fire divisions
-
14A.2.1.1 Fire divisions required by 14A.2.2 are to be constructed in accordance with the remaining
paragraphs of this sub-Section.
-
14A.2.1.2 Fire divisions using steel equivalent, or alternative forms of construction may be
accepted if it can be demonstrated that the material by itself, or due to non- combustible
insulation provided, has the fire resistance properties equivalent to those divisions
required by 14A.2.2.1.
-
14A.2.1.3 Insulation required by 14A.2.1.2 is to be such that the temperature of the structural
core does not rise above the point at which the structure would begin to lose its
strength at anytime during the applicable exposure to the standard fire test as referenced
in the IMO FTP Code. For 'A' Class divisions, the applicable exposure is 60 minutes,
and for 'B' Class divisions, the applicable exposure is 30 minutes.
-
14A.2.1.3.1 For aluminium alloy structures, the insulation is to be such that the temperature
of the structural core does not rise more than 200°C above the ambient temperature
at any time during the applicable fire exposure.
-
14A.2.1.3.2 For composite structures, the insulation is to be such that the temperature of the
laminate does not rise more than the minimum temperature of deflection under load
of the resin at any time during the applicable fire exposure. The temperature of
deflection under load is to be determined in accordance with a recognised international
standard.
-
14A.2.1.3.3 Insulation need only be applied on the side that is exposed to the greatest fire risk,
ie inside the engine room, a division between two such spaces should however be insulated
on both sides unless it is a steel division.
-
14A.2.1.3.4 Special attention is to be given to the fixing of fire door frames in bulkheads constructed
of materials other than steel. Measures are to be taken to ensure that the temperature
of the fixings when exposed to fire does not exceed the temperature at which the bulkhead
itself loses strength.
14A.2.2 Structural Fire Protection
-
14.A.2.2.1
-
(a) Machinery spaces of category ‘A’, are to be enclosed by ‘A-30’ Class boundaries. For
Short Range Yachts, such machinery spaces are to be enclosed by ‘B-15’ Class boundaries;
-
(b) Yachts which are not Short Range Yachts the keels of which are laid or are at a similar
stage of construction on or after 1 January 2015 are to have galleys enclosed by ‘B-15’
Boundaries. It is recommended that vessels constructed before this date also comply
with this requirement.
-
14A.2.2.2 Openings in 'A' and 'B' Class divisions are to be provided with permanently attached
means of closing that are to be at least as effective for resisting fires as the divisions
in which they are fitted. Generally, windows should not be fitted in machinery space
boundaries.
-
14A.2.2.3 Where 'A' Class divisions are penetrated for the passage of electric cables, pipes,
trunks, ducts, etc., or for girders, beams or other structural members, arrangements
are to be made to ensure that the fire resistance is not impaired.
-
14A.2.2.4 Where 'B' Class divisions are penetrated for the passage of electric cables, pipes,
trunks, ducts, etc., or for the fitting of ventilation terminals, lighting fixtures
and similar devices, arrangements are to be made to ensure that the fire resistance
is not impaired.
-
14A.2.2.5 Where the structure or 'A' Class divisions are required to be insulated, it is to
be ensured that the heat from a fire is not transmitted through the intersections
and terminal points of the divisions or penetrations to uninsulated boundaries. Where
the insulation installed does not achieve this, arrangements are to be made to prevent
this heat transmission by insulating the horizontal and vertical boundaries or penetrations
for a distance of 450 mm.
14A.2.3 Materials
-
14A.2.3.1 Except in refrigerated compartments of service spaces, all insulation (e.g. thermal
and acoustic) is to be of not readily-ignitable materials.
-
14A.2.3.2 Pipes penetrating 'A' or 'B' Class divisions are to be of approved materials having
regard to the temperature such divisions are required to withstand.
-
14A.2.3.3 Pipes conveying oil or other combustible liquids through accommodation and service
spaces are to be of approved materials having regard to the fire risk.
-
14A.2.3.4 Materials readily rendered ineffective by heat are not to be used for overboard scuppers,
sanitary discharges, and other outlets which are close to the waterline and where
the failure of the material in the event of fire would give rise to danger of flooding.
Due regard should be paid to the IMO Fire Test Procedures Code.
-
14A.2.3.5 Vapour barriers and adhesives used in conjunction with insulation, as well as insulation
of pipe fittings for cold service system need not be non-combustible, but they are
to be kept to the minimum quantity practicable and their exposed surfaces are to have
low flame spread characteristics.
-
14A.2.3.6 Upholstery composites (fabric in association with any backing or padding material)
used throughout the vessel including open decks should be approved in accordance with
the IMO FTP Code, Annex 1, Part 8, or equivalent. This does not apply to spaces fitted
with sprinklers or equivalent fixed fire extinguishing systems.
-
14A.2.3.7 Organic foams used in upholstered furniture and mattresses should be of the combustion
modified type.
-
14A.2.3.8 Suspended textile materials such as curtains or drapes should be approved in accordance
with the IMO FTP Code, Annex 1, Part 7, or equivalent. This does not apply to spaces
fitted with sprinklers or equivalent fixed fire extinguishing systems.
14A.2.4 Surface of Insulation
In spaces where penetration of oil products is possible, the surface of insulation
is to be impervious to oil or oil vapours. Insulation boundaries are to be arranged
to avoid immersion in oil spillages.
14A.2.5 Fuel Arrangements
-
14A.2.5.1 Arrangements for the storage, distribution and utilisation of oil fuel are to be such
as to minimise the risk of fire or explosion.
-
14A.2.5.2 Oil fuel tanks situated within, or adjacent to, the boundaries of Category 'A' machinery
spaces are not to contain oil fuel having a flashpoint of less than 60°C.
-
14A.2.5.3 Oil fuel, lubricating oil and other flammable oils are not to be carried in fore-peak
tanks.
-
14A.2.5.4 Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage,
settling or daily service tank situated above the double bottom, should be fitted
with a cock or valve directly on the tank capable of being closed from a safe position
outside the space concerned in the event of a fire occurring in the space in which
such tanks are situated.
-
14A.2.5.5 Means are to be provided to stop fuel transfer pumps, oil fired boilers and
separators from outside the machinery space.
-
14A.2.5.6 Fuel filter bowls should be of metal construction.
14A.3 Means of Escape
14A.3.1 Purpose
The purpose of this section is to provide means of escape so that persons onboard
can safely and swiftly escape to the liferaft embarkation deck. For this purpose,
the following functional requirements should be met:
-
• safe escape routes should be provided;
-
• escape routes should be maintained in a safe condition, clear of obstacles; and
-
• additional aids for escape should be provided as necessary to ensure accessibility,
clear marking, and adequate design for emergency situations.
14A.3.2 Requirements
-
14A.3.2.1 Stairways, ladders and corridors serving all spaces normally accessible are to be
arranged so as to provide ready means of escape to a deck from which embarkation into
survival craft may be effected.
-
14A.3.2.2 The arrangement of the vessel should be such that all compartments are provided
with a satisfactory means of escape. In the case of the accommodation, two means
of escape from every restricted space or group of spaces should be provided. Concealed
escapes and escape routes are to be clearly marked to ensure ready exit.
Category ‘A’ machinery spaces on motor vessels should also be provided with a minimum
of two means of escape. Other machinery spaces should also have at least two means
of escape as widely separated as possible, except where the small size of the machinery
space makes it impracticable.
-
(a) The normal means of access to the accommodation and service spaces below the open
deck is to be arranged so that it is possible to reach the open deck without passing
through a galley, engine room or other space with a high fire risk, wherever practicable.
-
(b) Where accommodation arrangements are such that access to compartments is through another
compartment, the second escape route is to be as remote as possible from the main
escape route. This may be through hatches of adequate size, leading to the open deck
or separate space to the main escape route.
-
(c) In exceptional circumstances a single means of escape may be accepted for spaces,
other than accommodation spaces, that are entered only occasionally, if the escape
route does not pass through a galley, machinery space or watertight door.
-
(d) No escape route should be obstructed by furniture or fittings. Additionally, furniture
along escape routes should be secured in place to prevent shifting if the yacht rolls
or lists.
-
(e) All doors in escape routes are to be openable from either side. In the direction of
escape they are all to be openable without a key. All handles on the inside of weathertight
doors and hatches are to be non removable. Where doors are lockable measures to ensure
access from outside the space are to be provided for rescue purposes.
-
14A.3.2.3 Lifts are not considered as forming a means of escape.
14A.4 Ventilation Systems
-
14A.4.1 Ventilation fans for machinery spaces and enclosed galleys are to be capable of being
stopped, and main inlets and outlets of ventilation systems closed, from outside the
spaces being served. This position should not be readily cut off in the event of a
fire in the spaces served.
-
14A.4.2 Ventilation ducts for Category 'A' machinery spaces, galleys, spaces containing vehicles
or craft with fuel in their tanks, or lockers storing such fuels, are generally not
to pass through accommodation spaces, service spaces or control stations. Where this
is unavoidable, the trunking should be constructed of steel at least 3mm thick or
equivalent to the satisfaction of the Administration. The ducting within the accommodation
should be fitted with:
-
.1 fire insulation to A-30 (B-15 on Short Range Yachts) standard to a point at least
5 metres from the boundary of the machinery space or galley; and
-
.2 automatic fire dampers located in the deck or bulkhead within the accommodation where
the trunking passes from the machinery space or galley into the accommodation. These
automatic fire dampers are also to be manually closable from outside the galley or
machinery space; and
-
.3 fixed means for extinguishing a fire within the galley exhaust duct.
-
14A.4.3 Ventilation ducts for accommodation spaces, service spaces or control stations are
not to pass through Category 'A' machinery spaces, galleys, spaces containing vehicles
or craft with fuel in their tanks, or lockers storing such fuels, unless the ducts
are constructed of steel and arranged to preserve the integrity of the division.
-
14A.4.4 Store-rooms containing highly flammable products are to be provided with ventilation
arrangements that are separate from other ventilation systems. Ventilation is to be
arranged to prevent the build up of flammable vapours at high and low levels. The
inlets and outlets of ventilators are to be positioned so that they do not draw from
or vent into an area which would cause undue hazard, and are to be fitted with spark
arresters.
-
14A.4.5 Ventilation systems serving Category 'A' machinery spaces are to be independent
of systems serving other spaces.
-
14A.4.6 All enclosed spaces containing free standing fuel tanks are to be ventilated
independently of systems serving other spaces.
-
14A.4.7 Ventilation is to be provided to prevent the accumulation of dangerous concentrations
of flammable gas which may be emitted from batteries.
-
14A.4.8 Ducts provided for tumble driers are to be fitted with suitably located cleaning and
inspection openings.
14A.5 Arrangements for Gaseous Fuel for Domestic Purposes
-
14A.5.1 Where gaseous fuel is used for domestic purposes, the arrangements for the storage,
distribution and utilisation of the fuel is to be such that, having regard to the
hazards of fire and explosion which the use of such fuel may entail, the safety of
the yacht and the persons onboard is preserved. The installation is to be in accordance
with recognised National or International Standards. Hydrocarbon gas detectors and
carbon monoxide detectors should be provided.
-
14A.5.2 Gas cylinders, regulators and safety devices should be stowed on the open deck (where
leakage will not accumulate) or in a compartment that is vapour-tight to the vessels
interior, and fitted with a vent and drain, so that any gas which may leak can disperse
overboard.
-
14A.5.3 An open flame gas appliance provided for cooking, heating or any other purpose should
comply with the requirements of EC Directive 90/396/EEC or equivalent.
The installation of an open flame gas appliance should comply with the appropriate
provisions of Annex 3.
14A.6 Space Heaters
Space heaters, if used, are to be fixed in position and so constructed as to reduce
fire risks to a minimum. The design and location of these units is to be such that
clothing, curtains or other similar materials cannot be scorched or set on fire by
heat from the unit.
14A.7 Fixed Fire Detection and Fire-Alarm Systems
-
14A.7.1 The purpose of this section is to detect a fire in the space of origin and to provide
for an alarm for safe escape and fire-fighting activity.
-
14A.7.2 A fixed fire detection and fire alarm system is to be fitted in all enclosed spaces
except those containing no significant fire risk (toilets, bathrooms, void spaces,
etc). Manually operated call points should be placed effectively to ensure a readily
accessible means of notification. The fixed fire detection and fire-alarm system is
to be installed in accordance with the requirements of SOLAS II-2/7 and the IMO Fire
Safety Systems Code, Chapter 9, and should be audible externally.
14A.8 Fixed Fire-Extinguishing Systems Not Required by this Section
Where a fixed fire-extinguishing system not required by this Chapter, is installed,
the arrangement is to be to the satisfaction of the Administration.
14B STRUCTURAL FIRE PROTECTION – VESSELS OF 500GT AND OVER
Objective: The purpose of this section is to ensure a consistent level of structural
fire protection. The principles of the section aim to achieve a level of fire protection
compatible with the requirements of SOLAS for passenger ships carrying up to 36
passengers. These have been adapted where appropriate to fit the general yacht
design philosophy. Much emphasis is placed on the provision of sprinkler/mist
systems as trade off for certain aspects.
|
14B.1 Definitions
Terms used in this section should have the same meaning as defined in SOLAS, except
as defined in Section 14.1 and as follows:
‘Not readily ignitable’ means that the surface thus described will not continue to
burn for more than 20 seconds after removal of a suitable impinging test flame.
14B.2 Table 14B.2 is a guide to the major requirements of this Section. The table
is intended as a quick reference to the requirements and is not to be used in isolation
when designing the fire safety arrangements.
Table 14B.2
All vessels should comply with the following:
Form of construction (see 14B.2.1)
|
Steel or equivalent, or alternative forms of construction may be accepted subject
to requirements.
|
Passive fire protection (see 14B.2.1 to 14B.2.7)
|
See Tables 1 and 2
|
Means of escape (see 14B.2.12)
• Category ‘A’ machinery spaces
• Accommodation, etc.
|
2 (two)
2 (two)
|
Fixed fire detection system (see 14B.2.14)
|
• Fitted in machinery spaces
• Fitted in service spaces, control stations and accommodation spaces
|
Fire extinguishing arrangements in Category ‘A’ machinery spaces (see 15B)
|
• As per SOLAS II-2/10.5
|
Automatic sprinkler system or equivalent(see14B.2.14)
|
Fitted in all vessels
|
14B.2.1 Structure
Purpose
The purpose of this section is to contain a fire in the space of origin. For this
purpose, the following functional requirements should be met:
-
• the ship should be subdivided by thermal and structural boundaries;
-
• thermal insulation of boundaries should have due regard to the fire risk of the space
and adjacent spaces;
-
• the fire integrity of the divisions should be maintained at openings and penetrations.
-
14B.2.2.1 The hull, superstructures, structural bulkheads, decks and deckhouses should be constructed
of steel or other equivalent material.
-
14B.2.2.2 However, in cases where any part of the structure is of aluminium alloy, the following
should apply:
-
.1 Insulation of aluminium alloy components of ‘A’ or ‘B’ class divisions, except structure
which, in the opinion of the Administration, is non-load- bearing, should be such
that the temperature of the structural core does not rise more than 200°C above the
ambient temperature at any time during the applicable fire exposure to the standard
fire test. This insulation is to be applied on all sides except for the upper sides
of decks and the outside of the vessel.
-
.2 Special attention should be given to the insulation of aluminium alloy components
of columns, stanchions and other structural members required to support lifeboat and
liferaft stowage, launching and embarkation areas, and ‘A’ and ‘B’ class divisions
to ensure that for members:
-
(a) supporting lifeboat and liferaft areas and ‘A’ class divisions, the temperature rise
limitation specified in .1 above should apply at the end of one hour; and
-
(b) supporting ‘B’ class divisions, the temperature rise limitation specified in .1 above
should apply at the end of half an hour.
-
.3 Aluminium alloy components of divisions that are required to be equivalent to steel
(identified by an * in tables 1 and 2) should be insulated with 25mm of mineral wool
approved for use in A class divisions or with an equivalent insulation acceptable
to the Administration.
-
14B.2.2.3 For composite structures, the insulation is to be such that the temperature of the
laminate does not rise more than the minimum temperature of deflection under load
of the resin at any time during the specified fire exposure. The temperature of deflection
under load is to be determined in accordance with the requirements of a recognised
international standard. This insulation is to be applied on all sides except for the
upper sides of decks and the outside of the vessel.
-
.1 Special attention should be given to the insulation of composite components of columns,
stanchions and other structural members required to support lifeboat and liferaft
stowage, launching and embarkation areas, and ‘A’ and ‘B’ class divisions to ensure
that for members:
-
(a) supporting lifeboat and liferaft areas and ‘A’ class divisions, the temperature rise
limitation specified in .1 above should apply at the end of one hour; and
-
(b) supporting ‘B’ class divisions, the temperature rise limitation specified in .1 above
should apply at the end of half an hour.
Special attention should be given to the fixing of fire door frames in bulkheads constructed
of materials other than steel. Measures are to be taken to ensure that the temperature
of the fixings when exposed to fire does not exceed the temperature at which the bulkhead
itself loses strength.
-
14B.2.2.4 Crowns and casings of a machinery space of category A should be A60 divisions and
openings therein, if any, should be suitably arranged and protected to prevent the
spread of fire.
-
14B.2.2.5 For structures in contact with sea-water, the required insulation should extend to
at least 300 mm below the lightest waterline.
-
14B.2.2.6 Fire divisions using steel equivalent, or alternative forms of construction may be
accepted if it can be demonstrated that the material by itself, or due to non- combustible
insulation provided, has the fire resistance properties equivalent to the A or B class
standard required.
-
14B.2.2.7 Insulation required by 14B.2.2.6 is to be such that the temperature of the structural
core does not rise above the point at which the structure would begin to lose its
strength at anytime during the applicable exposure to the standard fire test. For
'A' Class divisions, the applicable exposure is 60 minutes, and for 'B' Class
divisions, the applicable exposure is 30 minutes.
14B.2.3 Main Vertical Zones and Horizontal Zones
-
14B.2.3.1 Hull, superstructure and deckhouses in way of accommodation and service spaces
should be subdivided into main vertical zones by ‘A’ class divisions. These divisions
should have insulation values in accordance with tables 1 and 2.
-
14B.2.3.2 As far as practicable, the bulkheads forming the boundaries of the main vertical zones
above the bulkhead deck should be in line with watertight subdivision bulkheads situated
immediately below the bulkhead deck. The length and width of main vertical zones may
be extended to a maximum of 48 m in order to bring the ends of main vertical zones
to coincide with watertight subdivision bulkheads or in order to accommodate a large
public space extending for the whole length of the main vertical zone provided that
the total area of the main vertical zone is not greater than 800 m2 on any deck. The length or width of a main vertical zone is the maximum distance
between the furthermost points of the bulkheads bounding it.
-
14B.2.3.3 Such bulkheads should extend from deck to deck and to the shell or other boundaries.
-
14B.2.3.4 When a main vertical zone is subdivided by ‘A’ class divisions for the purpose of
providing an appropriate barrier between spaces protected and not protected by a sprinkler
system, the divisions should be insulated in accordance with the fire insulation and
integrity values given in tables 1 and 2.
14B.2.4 Bulkheads Within a Main Vertical Zone
-
14B.2.4.1 All bulkheads within accommodation and service spaces which are not required to be
‘A’ class divisions should be at least ‘B’ class or ‘C’ class divisions as prescribed
in the tables1 and 2.
-
14B.2.4.2 All such divisions may be faced with combustible materials
-
14B.2.4.3 All corridor bulkheads, where not required to be ‘A’ class should be ‘B’ class divisions
which should extend from deck to deck except:
-
.1 when continuous ‘B’ class ceilings or linings are fitted on both sides of the bulkhead,
the portion of the bulkhead behind the continuous ceilings or lining should be of
material which, in thickness and composition, is acceptable in the construction of
‘B’ class divisions but which should be required to meet ‘B’ class integrity standards
only in so far as is reasonable and practical in the opinion of the Administration;
-
.2 the corridor bulkheads of ‘B’ class materials may terminate at a ceiling in the corridor
provided such a ceiling is of material which, in thickness and composition, is acceptable
in the construction of ‘B’ class divisions. All doors and frames in such bulkheads
should be so constructed and erected to provide a ‘B’ class standard.
-
14B.2.4.4 All bulkheads required to be ‘B’ class divisions, except corridor bulkheads, should
extend from deck to deck and to the shell or other boundaries unless continuous ‘B’
class ceilings or linings are fitted on both sides of the bulkhead, in which case
the bulkhead may terminate at the continuous ceiling or lining.
14B.2.5 Fire Integrity of Bulkheads and Decks
-
14B.2.5.1 In addition to complying with the specific provisions for fire integrity of bulkheads
and decks mentioned elsewhere in this section, the minimum fire integrity of bulkheads
and decks should be as prescribed in tables 1 and 2.
-
14B.2.5.2 The following requirements should govern application of the tables:
-
.1 Tables 1 and 2 should apply respectively to the bulkheads and decks separating adjacent
spaces.
-
.2 For determining the appropriate fire integrity standards to be applied to divisions
between adjacent spaces, such spaces are classified according to their fire risk as
shown in categories (1) to (9) below. The title of each category is intended to be
typical rather than restrictive. The number in parentheses preceding each category
refers to the applicable column or row in the tables.
(1) Control stations
-
• Spaces containing emergency sources of power and lighting.
-
• Wheelhouse and chartroom.
-
• Spaces containing the vessel's radio equipment.
-
• Fire-extinguishing rooms.
-
• Fire control rooms and fire-recording stations.
-
• Control room for propulsion machinery when located outside the machinery space.
-
• Spaces containing centralized fire alarm equipment.
(2) Corridors and lobbies
(3) Accommodation spaces
-
• Cabins, dining rooms, lounges, offices, pantries containing no cooking appliances
(other than equipment such as microwave cookers and toasters), and similar spaces.
(4) Stairways
-
• Interior stairways, lifts and escalators (other than those wholly contained within
the machinery space(s)) and enclosures thereto.
-
• In this connection, a stairway which is enclosed only at one level should be regarded
as part of the space from which it is not separated by a fire door.
(5) Service spaces (low risk)
(6) Machinery spaces of category A,
(7) Other machinery spaces
-
• Spaces so defined, excluding machinery spaces of category A.
-
• Sprinkler, drencher or fire pump spaces.
(8) Service spaces (high risk)
-
• Galleys, pantries containing cooking appliances, paint and lamp rooms, lockers and
store-rooms having areas of 4m2 or more, spaces for the storage of flammable liquids, workshops other than those
forming part of the machinery spaces, and spaces containing vehicles or craft with
fuel in their tanks, or lockers storing such fuels storage lockers for gaseous fuels
for domestic purposes.
(9) Open decks
-
14B.2.5.3 Continuous ‘B’ class ceilings or linings, in association with the relevant decks or
bulkheads, may be accepted as contributing, wholly or in part, to the required insulation
and integrity of a division.
-
14B.2.5.4 External boundaries which are required to be of steel or other equivalent material
may be pierced for the fitting of windows and portlights provided that there is no
requirement for such boundaries to have ‘A’ class integrity elsewhere in this section.
Similarly, in such boundaries which are not required to have ‘A’ class integrity,
doors may be of combustible materials, substantially constructed.
Table 1 – Fire Integrity of Bulkheads Separating Adjacent Spaces
Spaces
|
(1)
|
(2)
|
(3)
|
(4)
|
(5)
|
(6)
|
(7)
|
(8)
|
(9)
|
Control stations
|
(1)
|
A-0c
|
A-0
|
A-60
|
A-0
|
A-15
|
A-60
|
A-15
|
A-60
|
*
|
Corridors and lobbies
|
(2)
|
|
Cd
|
B-0c
|
A-0a B-Od
|
B-0d
|
A-60
|
A-0
|
A-0
|
*
|
Accommodation spaces
|
(3)
|
|
|
Cd
|
A-0a B-0d
|
B-0d
|
A-60
|
A-0
|
A-0
|
*
|
Stairways
|
(4)
|
|
|
|
A-0a B-0d
|
A-0a B-0d
|
A-60
|
A-0
|
A-0
|
*
|
Service spaces (low risk)
|
(5)
|
|
|
|
|
Cd
|
A-60
|
A-0
|
A-0
|
*
|
Machinery spaces of category A
|
(6)
|
|
|
|
|
|
*
|
A-0
|
A-60
|
*
|
Other machinery spaces
|
(7)
|
|
|
|
|
|
|
A-0b
|
A-0
|
*
|
Service spaces (high risk)
|
(8)
|
|
|
|
|
|
|
|
A-0b
|
*
|
Open decks
|
(9)
|
|
|
|
|
|
|
|
|
|
Table 2 – Fire Integrity of Decks Separating Adjacent Spaces
Spaces above
|
(1)
|
(2)
|
(3)
|
(4)
|
(5)
|
(6)
|
(7)
|
(8)
|
(9)
|
Spaces below
|
Control stations (1)
|
A-0
|
A-0
|
A-0
|
A-0
|
A-0
|
A-60
|
A-0
|
A-0
|
*
|
Corridors and lobbies (2)
|
A-0
|
*
|
*
|
A-0
|
*
|
A-60
|
A-0
|
A-0
|
*
|
Accommodation spaces (3)
|
A-60
|
A-0
|
*
|
A-0
|
*
|
A-60
|
A-0
|
A-0
|
*
|
Stairways (4)
|
A-0
|
A-0
|
A-0
|
*
|
A-0
|
A-60
|
A-0
|
A-0
|
*
|
Service spaces (low risk) (5)
|
A-15
|
A-0
|
A-0
|
A-0
|
*
|
A-60
|
A-0
|
A-0
|
*
|
Machinery spaces of (6)category A
|
A-60
|
A-60
|
A-60
|
A-60
|
A-60
|
*
|
A- 60e
|
A-60
|
*
|
Other machinery spaces (7)
|
A-15
|
A-0
|
A-0
|
A-0
|
A-0
|
A-0
|
*
|
A-0
|
*
|
Service spaces (high risk) (8)
|
A-60
|
A-0
|
A-0
|
A-0
|
A-0
|
A-60
|
A-0
|
A-0
|
*
|
Open decks (9)
|
*
|
*
|
*
|
*
|
*
|
*
|
*
|
*
|
–
|
Notes: To be applied to both tables 1 and 2, as appropriate.
a For clarification on which applies, see 14B.2.4 and 14B.2.6.
b Where spaces are of the same numerical category and subscript b appears, a bulkhead or deck of the rating shown in the tables is only required when
the adjacent spaces are for a different purpose, e.g in category (9). A galley next
to a galley does not require a bulkhead but a galley next to a paint room requires
an ‘A-0’ bulkhead.
c Bulkheads separating the wheelhouse and chartroom from each other may be ‘B-0’ rating.
d For the application of 14B.2.3.1, ‘B-O’ and ‘C’, where appearing in table 1, should
be read as ‘A-0’.
e Fire insulation need not be fitted if the machinery space in category (7),in the
opinion of the Administration, has little or no fire risk.
* Where an asterisk appears in the tables, the division is required to be of steel
or other equivalent material but is not required to be of ‘A’ class standard.
For the application of 14B.2.3.1 an asterisk, where appearing in table 2, except for
category (9), should be read as ‘A-0’.
14B.2.6 Protection of Stairways and Lifts in Accommodation and Service Spaces
-
14B.2.6.1 A stairway should be of steel frame construction except where the Administration sanctions
the use of other equivalent material, and should be within enclosures formed of ‘A’
class divisions, with positive means of closure at all openings, except that:
-
.1 an isolated stairway which penetrates a single deck only may be protected at one level
only by at least ‘B’ class divisions and self-closing door(s); and
-
.2 stairways may be fitted in the open in a public space, provided they lie wholly within
such public space.
-
14B.2.6.2 A stairway enclosure should have direct communication with the corridors and be of
sufficient area to prevent congestion, having in view the number of persons likely
to use them in an emergency. In so far as is practical, stairway enclosures should
not give direct access to galleys, machinery spaces, service lockers, or other enclosed
spaces containing combustibles in which a fire is likely to originate.
-
14B.2.6.3 A lift trunk should be so fitted to prevent the passage of flame from one 'tween-
deck to another and should be provided with means of closing to permit the control
of draught and smoke.
14B.2.7 Openings in ‘A’ Class Divisions
-
14B.2.7.1 Except for hatches between store and baggage spaces, and between such spaces and
the weather decks, all openings should be provided with permanently attached means
of closing which should be at least as effective for resisting fires as the divisions
in which they are fitted.
-
14B.2.7.2 The construction of all doors and door frames in ‘A’ class divisions, with the means
of securing them when closed, should provide resistance to fire as well as the passage
of smoke and flame, as far as practical, equivalent to that of the bulkheads in which
the doors are situated.
Such doors and door frames should be constructed of steel or other equivalent material.
Sliding steel watertight doors need not be insulated.
-
14B.2.7.3 It should be possible for each door to be opened and closed from each side of the
bulkhead by one person only.
-
14B.2.7.4 Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures
other than power-operated watertight doors and those which are normally locked, should
satisfy the following requirements:
-
(a) the doors should be self-closing and be capable of closing with an angle of inclination
of up to 3.5° opposing closure;
-
(b) (b) the approximate time of closure for hinged fire doors should be no more than 40
seconds and no less than 10 seconds from the beginning of their movement with the
ship in the upright position. The approximate uniform rate of closure for sliding
doors should be of no more than 0.2 m/s and no less than 0.1 m/s with the ship in
the upright position;
-
(c) the doors, except those for emergency escape trunks, should be capable of remote release
from the continuously manned central control station, either simultaneously or in
groups and should also be capable of release, individually, from a position at the
door. Release switches should have an on-off function to prevent automatic resetting
of the system;
-
(d) hold-back hooks not subject to central control station release are prohibited;
-
(e) a door closed remotely from the central control station should be capable of being
re-opened from both sides of the door by local control. After such local opening,
the door should automatically close again;
-
(f) indication must be provided at the fire door indicator panel in the continuously manned
central control station whether each door is closed;
-
(g) the release mechanism should be so designed that the door will automatically close
in the event of disruption of the control system or central power supply;
-
(h) local power accumulators for power-operated doors should be provided in the immediate
vicinity of the doors to enable the doors to be operated after disruption of the control
system or central power supply at least ten times (fully opened and closed) using
the local controls;
-
(i) disruption of the control system or central power supply at one door should not impair
the safe functioning of the other doors;
-
(j) remote-released sliding or power-operated doors should be equipped with an alarm that
sounds at least 5s but no more than 10s after the door being released from the central
control station and before the door begins to move and continues sounding until the
door is completely closed;
-
(k) a door designed to re-open upon contacting an object in its path should re-open not
more than 1m from the point of contact;
-
(l) double-leaf doors equipped with a latch necessary for their fire integrity should
have a latch that is automatically activated by the operation of the doors when released
by the system;
-
(m) the components of the local control system should be accessible for maintenance and
adjusting;
-
(n) power-operated doors should be provided with a control system of an approved type
which should be able to operate in case of fire and be in accordance with the Fire
Test Procedures Code. This system should satisfy the following requirements:
-
• the control system should be able to operate the door at the temperature of at least
200°C for at least 60 min, served by the power supply;
-
• the power supply for all other doors not subject to fire should not be impaired; and
-
• at temperatures exceeding 200°C the control system should be automatically isolated
from the power supply and should be capable of keeping the door closed up to at least
945°C.
-
14B.2.7.5 Where 'A' Class divisions are penetrated for the passage of electric cables, pipes,
trunks, ducts, etc., or for girders, beams or other structural members, arrangements
are to be made to ensure that the fire resistance is not impaired.
14B.2.8 Openings in ‘B’ Class Divisions
-
14B.2.8.1 Doors and door frames in ‘B’ class divisions and means of securing them should provide
a method of closure which should have resistance to fire as far as practical equivalent
to that of the divisions except that a ventilation opening may be permitted in the
lower portion of such doors. When such an opening is in or under a door the total
net area of the opening(s) should not exceed 0.05m2.
When such an opening is cut in a door it should be fitted with a grill made of non-
combustible material. Doors should be noncombustible or of substantial construction.
-
14B.2.8.2 Where 'B' Class divisions are penetrated for the passage of electric cables, pipes,
trunks, ducts, etc., or for the fitting of ventilation terminals, lighting fixtures
and similar devices, arrangements are to be made to ensure that the fire resistance
is not impaired.
14B.2.9 Windows and Portlights (Also see 5.4 and 5.5)
-
14B.2.9.1 All windows and portlights in bulkheads within accommodation spaces, service spaces
and control stations should be so constructed to preserve the integrity requirements
of the type of bulkheads in which they are fitted.
-
14B.2.9.2 Glass is not to be installed as an interior main vertical zone, stairway enclosure
bulkhead, or within machinery space boundaries.
14B.2.10 Details of Construction
-
14B.2.10.1 In accommodation and service spaces, control stations, corridors and stairways:
-
.1 air spaces enclosed behind ceilings, panelling or linings should be suitably divided
by close-fitting draught stops not more than 14m apart; and
-
.2 in the vertical direction, enclosed air spaces, including those behind linings of
stairways, trunks, etc should be closed at each deck.
-
14B.2.10.2 The draught stops are to be non-combustible and are to form a continuation above
the ceiling of the bulkhead below or the other side of the panelling or lining to
the bulkhead, as far as possible.
-
14B.2.10.3 Where the structure or 'A' Class divisions are required to be insulated, it is to
be ensured that the heat from a fire is not transmitted through the intersections
and terminal points of the divisions or penetrations to uninsulated boundaries. Where
the insulation installed does not achieve this, arrangements are to be made to prevent
this heat transmission by insulating the horizontal and vertical boundaries or penetrations
for a distance of 450 mm.
-
14B.2.10.4 Without impairing the efficiency of the fire protection, the construction of ceilings
and bulkheads should allow a fire patrol to detect any smoke originating in concealed
and inaccessible places, except where there is no risk of fire originating in such
places.
-
14B.2.10.5 When gaseous fuel is used for domestic purposes, the arrangements for the storage,
distribution and utilisation of the fuel should be such that, having regard to the
hazards of fire and explosion which the use of such fuel may entail, the safety of
the vessel and the persons onboard are preserved.
In particular, open flame gas appliances provided for cooking, heating or any other
purposes, should comply with the requirements of EC directive 90/396/EEC or equivalent
and, the installation of open flame gas appliances should comply with the appropriate
provisions of Section 14A.5.
14B.2.11 Restricted Use of Combustible Materials
-
14B.2.11.1 Except in spaces protected by an automatic sprinkler system and fully addressable
fire detection system in accordance with 14B.2.14, all linings, grounds, and ceilings
should be of non-combustible materials.
-
14B.2.11.2 Insulation materials should be non-combustible, however core insulation of refrigerator
and cold rooms need not be. Vapour barriers and adhesives used in conjunction with
insulation, as well as insulation of pipe fittings for cold service systems need not
be non-combustible, but they should be kept to the minimum quantity practicable and
their exposed surfaces should have low flame spread characteristics.
-
14B.2.11.3 The following surfaces should be low flame spread:
-
.1 exposed surfaces in corridors and stairway enclosures, and of bulkheads, wall and
ceiling linings in all service spaces and control stations; and
-
.2 oncealed or inaccessible spaces in accommodation, service spaces and control stations.
As an alternative to .1 and .2 above, these spaces may contain surfaces that are not
low flame spread, provided
-
.3 adequate barriers of low flame spread surfaces are arranged to restrict the spread
of flame areas at distances not greater than 5m; or
-
.4 these spaces are protected by an automatic sprinkler system and fully addressable
fire detection system in accordance with 14B.2.14.
-
14B.2.11.4 Pipes penetrating 'A' or 'B' Class divisions are to be of approved materials having
regard to the temperature such divisions are required to withstand.
-
14B.2.11.5 Pipes conveying oil or combustible liquids through accommodation and service spaces
are to be of approved materials having regard to the fire risk.
-
14B.2.11.6 Materials readily rendered ineffective by heat are not to be used for overboard scuppers,
sanitary discharges, and other outlets which are close to the waterline and where
the failure of the material in the event of fire would give rise to the danger of
flooding.
-
14B.2.11.7 Furniture in the corridors and escape routes should be of a type and quantity not
likely to obstruct access. Additionally, furniture along escape routes should be secured
in place to prevent shifting if the vessel rolls or lists.
-
14B.2.11.8 Primary deck coverings within accommodation spaces, service spaces and control stations
are to be of a type which will not readily ignite, or give rise to toxic or explosive
hazards at elevated temperatures. Reference is also to be made to the IMO FTP Code,
Annex 1, Parts 2 and 6.
-
14B.2.11.9 Except when a fully addressable fire detection system is fitted, upholstery composites
(fabric in association with any backing or padding material) used throughout the vessel
and on open decks should be approved in accordance with the IMO FTP Code, Annex 1,
Part 8 or an equivalent standard acceptable to the Administration.
-
14B.2.11.10 Except when a fully addressable fire detection system is fitted bedding components
should be approved in accordance with the IMO FTP Code, Annex 1, Part 9 or an equivalent
standard acceptable to the Administration.
-
14B.2.11.11 Except when a fully addressable fire detection system is fitted, suspended textile
materials such as curtains and drapes should be approved in accordance with the IMO
FTP Code, Annex 1, Part 7, or an equivalent standard, acceptable to the Administration.
-
14B.2.11.12 Upholstery, bedding components and suspended textiles required to comply with the
IMO FTP code or an equivalent standard are to be clearly labelled by the manufacturer
stating the standard that they meet and any washing or cleaning instructions needed
to maintain their fire resistance. These labels are not to be removed.
-
14B.2.11.13 In spaces where penetration of oil products is possible, the surface of insulation
is to be impervious to oil or oil vapours. Insulation boundaries are to be arranged
to avoid immersion in oil spillages so far as is practicable.
14B.2.12 Means of Escape
Purpose
The purpose of this section is to provide means of escape so that persons onboard
can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this
purpose, the following functional requirements should be met:
-
• safe escape routes should be provided;
-
• escape routes should be maintained in a safe condition, clear of obstacles; and
-
• additional aids for escape should be provided as necessary to ensure accessibility,
clear marking, and adequate design for emergency situations.
-
14B.2.12.1 Stairways and ladders should be arranged to provide ready means of escape to the lifeboat
and liferaft embarkation deck from all guest and crew accommodation spaces and service
spaces in which the crew are normally employed, other than machinery spaces. In particular,
the following provisions should be complied with:
-
.1 Below the bulkhead deck two means of escape, at least one of which should be independent
of watertight doors, should be provided from each watertight compartment, main vertical
zone or similarly restricted group of spaces. Exceptionally one of the means of escape
may be dispensed with, due regard being paid to the nature and location of spaces
and to the number of persons who might normally be accommodated or employed there.
-
.2 Above the bulkhead deck, there are to be at least two means of escape from each vertical
fire zone or similarly restricted spaces or group of spaces, at least one of which
is to give access to a readily accessible escape which will provide continuous fire
shelter from the level of its origin to the appropriate survival craft embarkation
deck.
-
.3 Within each main vertical zone there should be at least one readily accessible enclosed
stairway providing continuous fire shelter, where practical, at all levels up to the
appropriate lifeboat and liferaft embarkation decks or the highest level served by
the stairway, whichever level is the highest. The width, number and continuity of
the stairways should be satisfactory for the number of persons likely to use them.
-
.4 Access from the stairway enclosures to the lifeboat and liferaft embarkation areas
should avoid high fire risk areas.
-
.5 Stairways serving only a space and a balcony in that space should not be considered
as forming one of the required means of escape.
-
.6 If a radio room or wheelhouse has no direct access to the open deck, two means of
escape should be provided, one of which may be a window of sufficient size or another
means.
-
.7 Stairways are not to exceed 3.5m vertical rise without the provision of a landing.
-
.8 In the case where direct access to the appropriate survival craft embarkation deck
as required by .1 and .2 is not practical, a ready accessible escape which will provide
continuous fire shelter from the level of its origin to the appropriate open deck
with subsequent direct passage to the embarkation deck can be accepted provided that
these escape routes including external staircases, have emergency lighting and slip
free surfaces under foot.
-
.9 Protection of access from the stairway enclosures to the lifeboat and liferaft embarkation
areas should be provided either directly or through protected internal routes which
have fire integrity and insulation values for stairway enclosures as determined by
tables 1 and 2, as appropriate.
-
.10 Where public spaces span three or more open decks and contain combustibles such as
furniture and give access to other enclosed spaces, each level within the space is
to have two means of escape, one of which is to give access to a readily accessible
escape which will provide continuous fire shelter from the level of its origin to
the appropriate survival craft embarkation deck.
-
14B.2.12.2 Two means of escape should be provided from each machinery space. In particular,
the following provisions should be complied with:
-
.1 The two means of escape should consist of either:
-
(a) two sets of steel ladders as widely separated as possible, leading to doors in the
upper part of the space similarly separated and from which access is provided to the
appropriate survival craft embarkation decks. One of these ladders should provide
continuous fire shelter from the lower part of the space to a safe position outside
the space. This shelter is to be of steel or equivalent material, insulated where
necessary, and provided with a self closing door at the lower end. If access is provided
at other levels each level is to be provided with a steel or equivalent material self-closing
door; or
-
(b) one steel ladder leading to a door in the upper part of the space from which access
is provided to the embarkation deck and additionally, in the lower part of the space
and in a position well separated from the ladder referred to, a steel door capable
of being operated from each side and which provides access to a safe escape route
from the lower part of the space to the embarkation deck.
-
.2 One of the means of escape from any such space required by 14B.2.12.2.1 may be dispensed
with on sailing vessels with small machinery spaces, so long as either a door or a
steel ladder and walkways provide a safe escape route to the embarkation deck with
due regard being paid to the nature and location of the space and whether persons
are normally employed in that space.
-
.3 Two means of escape should be provided from a machinery control room located within
a machinery space, at least one of which should provide continuous fire shelter to
a safe position outside the machinery space.
-
14B.2.12.3 Lifts should not be considered as forming one of the required means of escape.
-
14B.2.12.4 In exceptional circumstances a single means of escape may be accepted for spaces
other than accommodation spaces that are entered only occasionally, if the escape
route does not pass through a galley, machinery space or watertight door.
-
14B.2.12.5 Adequate deck area is to be provided at assembly stations and embarkation areas
having due regard to the expected number of persons. Generally, assembly stations
should be provided close to the embarkation stations. Each assembly station should
have sufficient clear deck space to accommodate all persons assigned to assemble at
that station, but at least 0.35m2 per person.
14B.2.12.6 Emergency Escape Breathing Devices
Emergency escape breathing devices (EEBD’s) should comply with the Fire Safety Systems
Code. At least one spare emergency escape breathing device should be kept onboard.
-
14B.2.12.6.1 All vessels should carry at least two EEBD’s within accommodation spaces, and at least
two EEBD’s should be carried in each main vertical zone.
-
14B.2.12.6.2 On all vessels, within the machinery spaces, EEBD’s should be situated ready for use
at easily visible locations, which can be reached quickly and easily at any time in
the event of fire. The number and location should take into account the layout of
the machinery space and the number of persons normally working in the space. The number
and location of these devices should be indicated in the fire control plan.
14B.2.13 Ventilation Systems
-
14B.2.13.1 Ventilation ducts should be of non-combustible material. Short ducts, however, not
generally exceeding 2m in length and with a cross-section not exceeding 0.02m2 need not be non-combustible, subject to the following conditions:
-
.1 they should be of a suitable material having regard to the risk of fire;
-
.2 they should be used only at the end of the ventilation device; and
-
.3 they should not be situated less than 600mm, measured along the duct, from an opening
in an ‘A’ or ‘B’ class division including continuous ‘B’ class ceilings.
-
14B.2.13.2 Where ventilation ducts with a free cross-sectional area exceeding 0.02m2 pass through class ‘A’ bulkheads or decks, the opening should be lined with a steel
sheet sleeve unless the ducts passing through the bulkheads or decks are of steel
in the vicinity of passage through the deck or bulkhead and the ducts and sleeves
should comply in this part with the following:
-
.1 Sleeves should have a thickness of at least 3mm and a length of at least 900mm. When
passing through bulkheads, this length should be divided preferably into 450mm on
each side of the bulkhead. The ducts, or sleeves lining such ducts, should be provided
with fire insulation. The insulation should have at least the same fire integrity
as the bulkhead or deck through which the duct passes.
-
.2 Ducts with a free cross-sectional area exceeding 0.075m2 should be fitted with fire dampers in addition to the requirements of .1 above. The
fire damper should operate automatically but should also be capable of being closed
manually from both sides of the bulkhead or deck. The damper should be provided with
an indicator which shows whether the damper is open or closed.
Fire dampers are not required, however, where ducts pass through spaces surrounded
by ‘A’ class divisions, without serving those spaces, provided those ducts have the
same fire integrity as the divisions which they pierce.
-
14B.2.13.3 Ducts provided for the ventilation of a machinery space of category A, galleys lies,
spaces containing vehicles or craft with fuel in their tanks or lockers storing such
fuel, should not pass through accommodation spaces, service spaces or control stations
unless they comply with the conditions specified in .1 to .4 or .5 and .6 below:
-
.1 they are constructed of steel having a thickness of at least 3mm and 5mm for duct
widths or diameters of up to and including 300mm and 760mm and over respectively and,
in the case of ducts with widths or diameters between 300mm and 760mm, thickness should
be obtained by interpolation;
-
.2 they are suitably supported and stiffened;
-
.3 they are fitted with automatic fire dampers close to the boundaries penetrated; and
-
.4 they are insulated to ‘A-60’ standard from a machinery space or galley to a point
at least 5m beyond each fire damper; or
-
.5 they are constructed of steel in accordance with .1 and .2 above; and
-
.6 they are insulated to ‘A-60’ standard throughout accommodation spaces, service spaces
or control stations; except that penetrations of main zone divisions should also comply
with the requirements of 14B.2.13.8.
-
14B.2.13.4 Ducts provided for ventilation to accommodation spaces, service spaces or control
stations, should not pass through a machinery space of category A, galley, spaces
containing vehicles or craft with fuel in their tanks or lockers storing such fuel,
unless they comply with the conditions specified in .1 to .3 or .4 and .5 below:
-
.1 where they pass through a machinery space of category A or galley, ducts are constructed
of steel in accordance with 14B.2.13.3.1 and .2;
-
.2 automatic fire dampers are fitted close to the boundaries penetrated; and
-
.3 the integrity of the machinery space or galley boundaries is maintained at penetrations
or;
-
.4 where they pass through a machinery space of category A or galley, ducts are constructed
of steel in accordance with 14B.2.13.3.1 and .2; and
-
.5 within a machinery space of category A or galley, ducts are insulated to ‘A-60’ standard;
except that penetrations of main zone divisions should also comply with the requirements
of 14B.2.13.8.
-
14B.2.13.5 Ventilation ducts with a free cross-sectional area exceeding 0.02m2 passing through
‘B’ class bulkheads should be lined with steel sheet sleeves of 900mm in length divided
preferably into 450mm on each side of the bulkheads, unless the duct is of steel for
this length.
-
14B.2.13.6 For a control station outside machinery spaces and other normally manned control
stations, practical measures should be taken to ensure that ventilation, visibility
and freedom from smoke are maintained so that, in the event of fire, the machinery
and equipment contained in the control station may be supervised and continue to function
effectively. Alternative and separate means of air supply should be provided; air
inlets of the two sources of supply should be so disposed that the risk of both inlets
drawing in smoke simultaneously is minimized. These requirements need not apply to
control stations situated on, and opening on to, an open deck, or where local closing
arrangements would be equally effective.
-
14B.2.13.7 Exhaust duct(s) from a galley range should be constructed of ‘A’ class divisions where
passing through accommodation spaces and/or spaces containing combustible materials.
In addition to the requirements of 14B.2.13.3 an exhaust duct should be fitted with:
-
.1 a grease trap readily removable for cleaning;
-
.2 a fire damper located in the lower end of the duct and in addition, a fire damper
in the upper end of the duct (if required for the extinguishing medium);
-
.3 arrangements for shutting off the exhaust fans;
-
.4 fixed means for extinguishing a fire within the duct;
-
.5 local controls to activate extinguishing system; stop the fans and close the fire
dampers should be grouped in one position immediately outside the main entrance to
the galley.
-
14B.2.13.8 When it is necessary for a ventilation duct to pass through a main vertical zone
division, a fail-safe automatic closing fire damper should be fitted adjacent to the
division. The damper should also be capable of being manually closed from each side
of the division. The operating position should be readily accessible and be marked
in red light-reflecting colour. The duct between the division and the damper should
be of steel or other equivalent material and, if necessary, insulated to comply with
the requirements of SOLAS regulation II-2/9.3.1. The damper should be fitted on at
least one side of the division with a visible indicator showing whether the damper
is in the open position.
-
14B.2.13.9 Inlets and outlets of ventilation systems should be capable of being closed from outside
the space being ventilated.
-
14B.2.13.10 Power ventilation of accommodation spaces, service spaces, control stations and machinery
spaces should be capable of being stopped from an easily accessible position outside
the space being served. This position should not be readily cut off in the event of
a fire in the spaces served. The means provided for stopping the power ventilation
of a machinery space should be entirely separate from the means provided for stopping
ventilation of other spaces.
-
14B.2.13.11 Where public spaces span three or more open decks and contain combustibles such as
furniture, and other enclosed spaces, the space is to be equipped with a smoke extraction
system. The smoke extraction system is to be activated by the smoke detection system
required by 14B.2.14 and is to be capable of manual control. The fans are to be capable
of exhausting the entire volume within the space in not more than 10 min.
-
14B.2.13.12 Store-rooms containing highly flammable products are to be provided with ventilation
arrangements that are separate from other ventilation systems. Ventilation is to be
arranged to prevent the build up of flammable vapours at high and low levels. The
inlets and outlets of ventilators are to be positioned so that they do not draw from
or vent into an area which would cause undue hazard, and are to be fitted with spark
arresters.
-
14B.2.13.13 Ventilation systems serving Category ‘A’ machinery spaces are to be independent of
systems serving other spaces.
-
14B.2.13.14 All enclosed spaces containing free standing fuel tanks are to be ventilated independently
of systems serving other spaces.
-
14B.2.13.15 Ventilation is to be provided to prevent the accumulation of dangerous concentrations
of flammable gas which may be emitted from batteries.
-
14B.2.13.16 Ventilation openings may be fitted in and under the lower parts of cabin and public
space doors in corridor bulkheads. The total net area of any such openings is not
to exceed 0.05m2.
-
14B.2.13.17 For spaces containing vehicles or craft with fuel in their tanks or lockers storing
such fuels, see 14.1.5. For additional requirements for the ventilation of domestic
gaseous fuel, see 14A.5.
-
14B.2.13.18 Ducts provided for exhaust ventilation from tumble driers are to be fitted with suitable
located cleaning and inspection openings.
-
14B.2.13.19 All fire dampers should comply with IMO Resolution A.754(18) pt A11 as referenced
in IMO FTP Code, Annex 1, Part 3.
14B.2.14 Fixed Fire Detection and Fire Alarm Systems and Automatic Sprinkler, Fire
Detection and Fire Alarm Systems
Purpose
The purpose of this section is to detect a fire in the space of origin and to provide
for alarm for safe escape and fire-fighting activity. For this purpose, the following
functional requirements should be met:
-
• fixed fire detection and fire alarm system installations should be suitable for the
nature of the space, fire growth potential and potential generation of smoke and gases;
and
-
• manually operated call points should be placed effectively to ensure a readily accessible
means of notification.
-
14B.2.14.1 Each separate zone in all accommodation and service spaces, except spaces which afford
no substantial fire risk such as void spaces, sanitary spaces, etc., should be provided
throughout with an automatic sprinkler, fire detection and fire alarm system of an
approved type and complying with the requirements of SOLAS 74, Chapter II-2 Part C,
regulation II-2/7 and the IMO FSS Code, Chapter 8, or an equivalent standard acceptable
to the Administration. The system should be designed to enable simultaneous operation
of all sprinklers fitted in the most hydraulically demanding area. The minimum area
for simultaneous operation may be taken as the largest area bounded by ‘A-O’ class
bulkheads or the breadth of the vessel squared, whichever is the greater, subject
to a maximum of 280m2.
-
14B.2.14.2 A fixed fire detection and fire alarm system is to be fitted in all enclosed spaces
except those containing no significant fire risk (toilets, bathrooms, void spaces,
etc). Manually operated call points should be placed to ensure a readily accessible
means of notification. The fixed fire detection and fire-alarm system is to be installed
in accordance with the requirements of SOLAS II-2/7 and the IMO Fire Safety Systems
Code, Chapter 9, and should be audible externally.
14B.2.15 Public Address System
-
14B.2.15.1 For vessels having a length of 85 m or more, a public address system complying with
the requirements of SOLAS 74. Chapter III, regulation 6.5 is to be available throughout
the accommodation and service spaces and control stations and open decks.
14B.2.16 Oil Fuel Arrangements
-
14B.2.16.1 Arrangements for the storage, distribution and utilisation of oil fuel are to be such
as to minimise the risk of fire or explosion.
-
14B.2.16.2 As far as practicable, oil fuel tanks are to be part of the vessel's structure and
are to be located outside Category 'A' machinery spaces.
-
14B.2.16.3 Where oil fuel tanks, other than double bottom tanks, are necessarily located adjacent
to or within Category 'A' machinery spaces, at least one of their vertical sides is
to be contiguous to the machinery space boundaries, and is preferably to have a common
boundary with the double bottom tanks, and the area of the tank boundary common with
the machinery spaces is to be kept to a minimum. Where the vertical boundary of a
tank directly exposed to a machinery space meets the vessel's side plating at an acute
angle, a small horizontal surface at the base of the tank, necessary to accommodate
practical constructional considerations may be permitted. If the arrangement of the
machinery is such that a tank with a large horizontal surface at the base is necessary
then a cofferdam with suitable ventilation arrangements, to protect the base of the
tank from the effect of a machinery space fire, will be specially considered. Oil
fuel tanks situated within the boundaries of Category 'A' machinery spaces are not
to contain oil fuel having a flashpoint of less than 60°C. Except for vessels constructed
of materials other than steel, where steel tanks should be provided, the use of free
standing oil fuel tanks is prohibited.
14B.2.17 Lubricating Oil Arrangements
Arrangements for the storage, distribution and utilisation of oil used in pressure
lubrication systems are to be such as to minimise the risk of fire or explosion.
14B.2.18 Arrangements for Other Flammable Oils
Arrangements for the storage, distribution and utilisation of other flammable oils
employed under pressure in power transmission systems, control and activating systems
and heating systems are to be such as to minimise the risk of fire or explosion.
14B.2.19 Prohibition of Carriage of Flammable Oils in Forepeak Tanks
Oil fuel, lubricating oil and other flammable oils are not to be carried in forepeak
tanks.
14B.2.20 Arrangements for Gaseous Fuel for Domestic Purposes
Where gaseous fuel is used for domestic purposes, the arrangements for the storage,
distribution and utilization of the fuel are to be such that, having regard to the
hazards of fire and explosion which the use of such fuel may entail, the safety of
the vessel and the persons on board is preserved. The installation is to be in accordance
with recognised national or international standards and is to meet the requirements
contained in 14A.5.
14B.2.21 Space Heaters
Space heaters, if used, are to be fixed in position and so constructed as to reduce
fire risks to a minimum. The design and location of these units is to be such that
clothing, curtains or other similar materials cannot be scorched or set on fire by
heat from the unit.
15A FIRE APPLIANCES – VESSELS OF LESS THAN 500GT
15A.1 General Requirements
-
15A.1.1 Fire appliances are to be of an approved type and should be provided to meet the minimum
requirements listed in Table 1 and the specific requirements of 15A.2.
-
15A.1.2 Fire appliances provided in addition to those required by 15A.1.1 should be of a type
acceptable to the Administration.
-
15A.1.3 The location of concealed fire appliances should be clearly marked.
Table 1 – FIRE APPLIANCES – VESSELS OF LESS THAN 500GT
1
|
PROVISION OF WATER JET – sufficient to reach any part of vessel
|
1
|
2
|
POWER DRIVEN FIRE PUMP – engine or
independent drive
|
1
|
3
|
ADDITIONAL INDEPENDENT POWER DRIVEN FIRE PUMP, POWER SOURCE
AND SEA CONNECTION – not located in the same space as item 2
|
1
|
4
|
FIREMAIN & HYDRANTS –
|
Sufficient to achieve item 1 with a single length of hose
|
5
|
HOSES – with jet/spray nozzles each fitted with a shut-off facility
|
3
|
6
|
FIRE EXTINGUISHERS –
portable,(accommodation and service spaces)
|
For each deck, 1 within 10m of any position within an accommodation or service space
|
7
|
FIRE EXTINGUISHERS – for a machinery space of Category A – the options are:
(a) a fixed fire extinguishing system approved in accordance with the IMO Fire Safety
Systems Code; and
|
|
|
(b) (i) 1 portable extinguisher for oil fires for each 74.6kw power; or
(ii) 2 portable extinguishers for oil fires together with either
1 foam extinguisher of 45l capacity; or 1 CO2 extinguisher of 16kg capacity
|
7 (max)
2 + 1
|
8
|
FIREMANS OUTFIT – to include an approved breathing apparatus for each outfit
|
2
|
9
|
FIRE BLANKET – in galley
|
1
|
15A.2 Specific Requirements
15A.2.1 Provision of Water Jet
At least one jet of water, from a single length of hose, should be able to reach any
part of the vessel normally accessible to passengers or crew while the vessel is being
navigated and, any store room or any part of a storage compartment when empty.
15A.2.2 Fire Pumps
-
15A.2.2.1 The power driven fire pump should have a capacity of
2.5x{1+0.066x(L(B+D))0.5}2 m3 /hour
where:
L = the length
B = the greatest moulded breadth
D = the moulded depth measured to the bulkhead deck at amidships.
When discharging at full capacity through 2 adjacent fire hydrants, the pump
should be capable of maintaining a water pressure of 0.2N/mm2 at any hydrant, provided the fire hose can be effectively controlled at this pressure.
-
15A.2.2.2 The second fire pump, which may be portable, should have a capacity of at least 80%
of that required by 15A.2.2.1 and be capable of input to the fire main. A permanent
sea connection, external to the machinery space, should be provided. ‘Throw-over’
sea suctions are not acceptable.
-
15A.2.2.3 Each centrifugal fire pump should be provided with a non-return valve in the connection
to the fire main.
15A.2.3 Fire Main and Hydrants
-
15A.2.3.1 A fire main, water service pipes and fire hydrants should be fitted.
-
15A.2.3.2 The fire main and water service pipe connections to the hydrants should be sized for
the maximum discharge rate of the pump(s) connected to the main.
-
15A.2.3.3 The fire main, water service pipes and fire hydrants should be constructed such that
they will:
-
.1 not be rendered ineffective by heat;
-
.2 not readily corrode; and
-
.3 be protected against freezing.
-
15A.2.3.4 When a fire main is supplied by 2 pumps, 1 in the machinery space and 1 elsewhere,
provision should be made for isolation of the fire main within the machinery space
and for the second pump to supply the fire main and hydrants external to the machinery
space. Isolation valve(s) should be manually operated valves fitted outside the machinery
space in a position easily accessible in the event of a fire.
-
15A.2.3.5 The fire main should have no permanent connections other than those necessary for
fire fighting or washing down.
-
15A.2.3.6 Fire hydrants should be located for easy attachment of fire hoses, protected from
damage and distributed so that a single length of the fire hoses provided can reach
any part of the vessel.
-
15A.2.3.7 Fire hydrants should be fitted with valves that allow a fire hose to be isolated and
removed when a fire pump is operating.
15A.2.4 Fire Hoses
-
15A.2.4.1 Fire hoses should not exceed 20 metres in length, and generally, the diameter for
use with a powered pump should not be less than 38mm.
-
15A.2.4.2 Fire hoses and associated tools and fittings should be kept in readily accessible
and known locations, close to the hydrants or connections on which they will be used.
Hoses supplied from a powered pump should have jet/spray nozzles (incorporating a
shut-off facility) of diameter 19mm, 16mm or 12mm depending on fire fighting purposes.
For accommodation and service spaces, the diameter of nozzles need not exceed 12mm.
For machinery spaces and exterior locations, the nozzle size should be as to obtain
the maximum discharge possible from two jets at the pressure referred to in 15A.2.2.1,
from the smallest pump.
-
15A.2.4.3 Hydrants or connections in interior locations on the vessel should have hoses connected
at all times. For use within accommodation and service spaces, proposals to provide
a smaller diameter of hoses and jet/spray nozzles will be considered.
-
15A.2.4.4 The number of fire hoses and nozzles provided should correspond to the functional
fire safety requirements, but be at least 3.
15A.2.5 Portable Fire Extinguishers for Use in Accommodation and Service Spaces
-
15A.2.5.1 The number, location, fire extinguishing medium type and capacity should be selected
according to the perceived fire risk, but for each deck, one portable extinguisher
should be available for use within a distance of 10m from any location. A minimum
of at least 3 portable fire extinguishers should be provided. As far as practical,
the fire extinguishers provided should have a uniform method of operation and should
be of an approved 5kg/9 litre type and capacity.
-
15A.2.5.2 Portable fire extinguishers of the carbon dioxide type should not be located or provided
for use in accommodation spaces.
-
15A.2.5.3 Except for portable extinguishers provided in connection with a specific hazard within
a space when it is manned (such as a galley), portable extinguishers generally should
be located external to, but adjacent to, the entrance of the space(s) in which they
will be used. Extinguishers should be stowed in readily accessible and marked locations.
-
15A.2.5.4 Spare charges should be provided onboard for at least 50% of each type and capacity
of portable fire extinguisher onboard. When an extinguisher is not of a type which
is rechargeable when the vessel is at sea, an additional portable fire extinguisher
of the same type (or its equivalent) should be provided.
15A.2.6 Fire Extinguishing in Machinery Spaces
-
15A.2.6.1 In a category A machinery space containing internal combustion type machinery, fire
appliances should be provided at least to the extent listed in item 7 of Table 1 –
Fire Appliances.
-
15A.2.6.2 In a machinery space containing an oil fired boiler, oil fuel settling tank or oil
fuel unit, a fixed fire extinguishing system complying with the IMO Fire Safety Systems
Code should be installed.
-
15A.2.6.3 Portable fire extinguishers should be installed and the number, location, fire extinguishing
medium type and capacity should be selected according to the perceived fire risk in
the space. (Spare charges or spare extinguishers should be provided per 15A.2.5.4.)
In any case, portable fire extinguishers for extinguishing oil fires should be fitted:
-
.1 in a boiler room – at least 2;
-
.2 in a space containing any part of an oil fuel installation – at least 2; and
-
.3 in a firing space – at least 1.
15B FIRE APPLIANCES – VESSELS OF 500GT AND OVER
All vessels should comply with the requirements of SOLAS 74, Chapter II-2, regulation
10. as may be amended, and as appropriate to the vessel and its equipment. For the
purpose of the SOLAS regulations, the standards for a cargo ship apply.
In no case should the standards applied be less than those applied to a vessel of
less than 500GT.
The location of concealed fire appliances should be clearly marked.
16 RADIO
16.1 Application
16.2 Radio Communications: The Global Maritime Distress and Safety System (GMDSS)
-
16.2.1 Each vessel should carry sufficient radio equipment to perform the following distress
and safety communications functions throughout its intended voyage:
-
.1 transmitting ship to shore distress alerts by at least two separate and independent
means, each using a different radio communication service;
-
.2 receiving shore-to-ship distress alerts;
-
.3 transmitting and receiving ship-to-ship distress alerts;
-
.4 transmitting and receiving search and rescue co-ordinating communications;
-
.5 transmitting and receiving on-scene communications;
-
.6 transmitting and receiving signals for locating by radar;
-
.7 transmitting and receiving maritime safety information; and
-
.8 transmitting and receiving bridge-to-bridge communications.
-
16.2.2 Existing vessels should carry sufficient radio equipment for distress and safety communications
to the satisfaction of the Administration. The radio equipment carried should not
be less than that specified in Table 1 of this section.
-
16.2.3 Notwithstanding the requirements in Table 1 of this section, it is strongly recommended
that existing vessels regardless of size should carry the radio equipment according
to the area of operation specified in Table 2.
16.3 Radio Installations
-
16.3.1 Table 1 illustrates the minimum radio installations to be carried by an existing vessel
sailing at different distances from a safe haven.
Table 1
Radio Equipment
|
Distance from safe haven – nautical miles
|
Up to 30
|
Up to 60
|
Up to 150
|
Unlimited
|
VHF Radio telephone with Digital Selective Calling (DSC)
|
One
|
One
|
One
|
One
|
MF/HF Radio Telephone with Digital Selective Calling (DSC)
|
None3
|
None3
|
One1
|
One1
|
INMARSAT Ship Earth Station
|
None
|
None
|
One1
|
One1
|
NAVTEX receiver
|
None
|
None
|
One2
|
One2
|
Notes:
1. An INMARSAT Ship Earth Station OR a MF/HF radiotelephone with DSC may be fitted
for operations over 60 miles from a safe haven. When a vessel operates north of 70
degrees North, or south of 70 degrees South, an INMARSAT Ship Earth Station and MF/HF
is required due to lack of coverage also, IRIDIUM is recommended.
2. If the vessel is sailing in an area where an international NAVTEX service is not
provided then the NAVTEX receiver should be supplemented by an INMARSAT enhanced group
calling system.
3. For existing vessels it is strongly recommended that MF/HF DSC or INMARSAT option
is fitted to cover the sea area outside of A1.
-
16.3 Example:
As an illustration, the minimum equipment to be installed on an existing vessel operating
worldwide would be:
one VHF radiotelephone with DSC; one INMARSAT -C ship earth station; one NAVTEX receiver;
one MF/HF radiotelephone with DSC.
Note: The requirements for the carriage of two way radiotelephone sets, EPIRBs and
SARTs are given in chapter 13, table 1. EPIRBs for vessels operating in Sea Area A4
are to be capable of operating through the polar orbiting satellite service in the
406 MHz band.
-
16.3.3 Table 2 illustrates the minimum radio installations to be carried by new vessels and
on vessels subject to major conversion. This fulfils the distress and safety communication
functions for voyages in Sea Areas A1, A2, A3 and A4.
Table 2
A1
|
A1+A2
|
A1+A2+A3
|
A1+A2+A3+A4
|
either
|
Or
|
NAVTEX1
|
NAVTEX1
|
NAVTEX1
|
NAVTEX1
|
NAVTEX1
|
VHF (DSC)
Radiotelephone
|
VHF (DSC)
Radiotelephone
|
VHF (DSC)
Radiotelephone
|
VHF (DSC)
Radiotelephone
|
VHF (DSC)
Radiotelephone
|
–
|
MF (DSC)
Radiotelephone2
|
MF (DSC)
Radiotelephone
|
MF/HF (DSC)
Radiotelephone2
|
MF/HF (DSC)
Radiotelephone2
|
–
|
–
|
INMARSAT C
Ship Earth Station
|
Notes:
1 If the vessel is sailing in an area where an international NAVTEX service is not
provided then the NAVTEX receiver should be supplemented by an additional means of
receiving MSI transmissions such as the Inmarsat enhanced group calling system.
2 Incorporating direct-printing telegraphy or an alternative means of receiving MSI
transmissions in the Sea Areas in which the vessel is operating.
The requirements for the carriage of two way radiotelephone sets, EPIRBs and SARTs
are given in Section 13, Table 1. EPIRBs for vessels operating in Sea Area A4 are
to be capable of operating through the polar orbiting satellite service in the 406
MHz band.
16.4 Operational Performance
16.5 Installation
16.6 Sources of Energy
-
16.6.1 Vessels <300GT should have sufficient reserve energy supply to operate the radio installations
for a minimum of 3 hours in addition to the emergency supply.
-
16.6.2 Vessels ≥300GT but <500GT NOT meeting the emergency source of electrical energy requirements
of SOLAS II-1/Part D, Regulation 43, should have sufficient reserve energy supply
to operate the radio installations for a minimum of 6 hours in addition to the emergency
supply.
-
16.6.3 All vessels ≥300 GT meeting the emergency requirements of SOLAS II-1/D, Regulation
43 should have a one hour reserve supply.
When a reserve source of energy consists of a rechargeable accumulator battery, a
means of automatically charging such batteries should be provided, which is capable
of recharging them to minimum capacity requirements within 10 hours which should include
a visual and audible charger failure device.
-
16.6.4 The siting and installation of accumulator batteries should ensure the highest degree
of service and safety.
16.7 Watches
16.8 Radio Personnel
16.9 Availability of Equipment
17 NAVIGATION LIGHTS, SHAPES AND SOUND SIGNALS
-
17.1 Every vessel should comply with the requirements of the International Regulations
For Preventing Collisions At Sea, 1972, as amended.
-
17.2 All navigation lights should be provided with main and emergency power supply.
-
17.3 With due regard to accessibility, the requirement for duplication for navigation lights
required to be shown whilst underway may be satisfied by having spare bulbs that can
be easily fitted within three minutes. However, on yachts over 500GT these must be
duplicate lights.
-
17.4 For vessels where compliance is impracticable, alternatives may be considered by application
to the Administration.
18 NAVIGATIONAL EQUIPMENT AND VISIBILITY FROM WHEELHOUSE
18.1 Navigational Equipment
-
18.1.1 A vessel should be fitted with the following:
-
.1 A properly adjusted standard magnetic compass or other means, independent of any power
supply, to determine the ship’s heading.
-
.2 In a steel vessel, it should be possible to correct the compass for co- efficients
B, C and D, and heeling error
-
.3 The magnetic compass or repeater should be so positioned as to be clearly readable
by the helmsman at the main steering position. It should also be provided with an
electric light, the electric power supply of which should be of the twin wire type.
-
18.1.2 A vessel should be fitted with the following additional equipment:
-
.1 an echo sounder;
-
.2 a receiver for a global navigation satellite system or a terrestrial radio-navigation
system, or other means suitable for use at all times throughout the intended voyage,
to establish and update the ship’s position by automatic means;
-
.3 speed and distance measuring device, or other means, to indicate speed and distance
through the water;
-
.4 a gyro compass or spare magnetic compass bowl;
-
.5 a rudder angle indicator; and
-
.6 a 9 GHz radar.
-
18.1.3 For vessels of less than 300GT the equipment specified in 18.1.1 and 18.1.2 need
not be of an approved type.
-
18.1.4 Means should be provided for taking bearings as near as practicable over an arc of
the horizon of 360°. This requirement may be met by the fitting of a pelorus compass,
or, on a vessel other than a steel vessel, with a hand bearing compass.
-
18.1.5 For vessels under 300GT the requirements of 18.1.2.4 may be met by the use of a fluxgate
compass, provided that a suitable back up power supply is available to power the compass
in the event of failure of the main electrical supply. Where such a compass incorporates
a capability to measure magnetic deviation by undertaking a calibration routine, and
where the deviation figures are recorded within the device, a deviation card is not
required.
-
18.1.6 Attention should be paid to magnetic effects on magnetic compasses, including fluxgate
compasses, when operating in Polar Regions (i.e. north of 70° N, or south of 70° S).
-
18.1.7 All vessels of 300GT and over should be fitted with an approved automatic identification
system (AIS) in accordance with SOLAS Chapter V,. The AIS should:
-
.1 provide automatically to appropriately equipped shore stations, other ships and aircraft,
information including the ships identity, type, position, course, speed, navigational
status and other safety related information;
-
.2 receive automatically such information from similarly fitted ships;
-
.3 monitor and track ships; and
-
.4 exchange data with shore- based facilities.
-
18.1.8 All vessels of 300GT and over, unless operating solely within sea area A1, should
be fitted with a Long-Range Identification and Tracking (LRIT) system to automatically
transmit the identity of the ship; the position of the ship, (latitude and longitude);
and the date and time of position provided.
The required shipborne equipment should as a minimum:
-
.1 be capable of automatically, and without human intervention on board the ship, transmitting
the ship’s LRIT information at 6-hour intervals to an LRIT Data Centre;
-
.2 be capable of being configured remotely to transmit LRIT information at variable intervals;
-
.3 be capable of transmitting LRIT information following receipt of polling commands;
-
.4 interface directly to the shipborne global navigation satellite system equipment,
or have internal positioning capability;
-
.5 be supplied with energy from the main and emergency source of electrical power; and
-
.6 be tested for electromagnetic compatibility taking into account the recommendations
developed by the IMO.
The current list of Authorised Testing Application Service Providers (ATASP’s) are
contained in Marine Information Note MIN 343, as may be amended.
-
18.1.9 All vessels should be fitted with a bridge navigational watch alarm system (BNWAS),
in accordance with SOLAS Chapter V Regulation 19 as follows:
-
18.1.9.1 Vessels of 150 gross tonnage and upwards constructed on or after 1 July 2011;
-
18.1.9.2 Vessels of 500 gross tonnage and upwards but less than 3,000 gross tonnage constructed
before 1 July 2011, not later than the first survey after 1 July 2013; and
-
18.1.9.3 Vessels of 150 gross tonnage and upwards but less than 500 gross tonnage constructed
before 1 July 2011, not later than the first survey after 1 July 2014.
-
18.1.9.4 A bridge navigational watch alarm system (BNWAS) installed prior to 1 July 2011 may
subsequently be exempted from full compliance with the standards adopted by the IMO,
at the discretion of the Administration.
The bridge navigational watch alarm system should be in operation whenever the ship
is underway at sea.
-
18.1.9.10 Vessels of 3000 GT and over should comply with the requirements of SOLAS Chapter V
Regulation 19.
18.2 Bridge Visibility
-
18.2.1 Navigation bridge visibility should comply with SOLAS Chapter V. Vessels under 55m
in length should comply as far as reasonable and practicable.
-
18.2.2 Windows may be inclined from the vertical plane provided that, where necessary, appropriate
measures are taken to avoid adverse reflections from within.
-
18.2.3 Windows to the navigating position should not be of either polarised or tinted glass
(see 5.5.8.) Portable tinted screens may be provided for selected windows.
19 MISCELLANEOUS EQUIPMENT
19.1 Nautical Publications
Every vessel should carry nautical charts and nautical publications to plan and display
the ship’s route for the intended voyage and to plot and monitor positions throughout
the voyage.
An approved electronic chart display and information system (ECDIS) may be accepted
as meeting these chart carriage requirements.
Back-up arrangements to meet these functional requirements should be provided where
this function is partly or fully filled by electronic means: this means single ECDIS
and paper charts or duplicate ECDIS. Where duplicate ECDIS is provided as the primary
means of navigation, officers with responsibility for navigation watch keeping should
have received appropriate shore based and ship type-specific training.
19.2 Measuring Instruments
Every vessel should carry a barometer. Every sailing vessel should carry an anemometer
and an inclinometer.
19.3 Signalling Lamp
Every vessel should carry a daylight signalling lamp, or other means to communicate
by light during day and night using an energy source of electrical power not solely
dependent upon the ship's power supply. The signalling lamp may be the searchlight
required by 19.4.
19.4 Searchlight
Every vessel should carry an efficient fixed or portable searchlight suitable for
man-overboard search and rescue operations.
19.5
Vessels of <150 GT require a radar reflector.
19.6
Vessels of >300 GT must be marked externally with the vessel’s IMO number which may
be horizontal provided that it is visible from the air.
20 ANCHORS AND CABLES
Objective: The purpose of this section is to set out the minimum standard for anchoring
and mooring arrangements. It should be noted that this element is to be an integral
part of the Classification process and this should be reflected in the Class Notation.
|
20.1 Equipment
-
20.1.1 Vessels will be considered to have adequate equipment if fitted out in accordance
with standards for such equipment, set by an approved Classification Society.
-
20.1.2 Vessels not equipped in accordance with 20.1.1 may be specially considered by the
Administration, provided full information is submitted for approval.
-
20.1.3 All vessels are to have at least 2 anchors, one of which must be ready for use at
all times. Any powered deployment system should be connected to an emergency power
supply or be capable of being manually operated.
20.2 Sailing Vessels
-
20.2.1 20.2.1 The sizing of anchors and cables for sailing vessels should take into account
the additional windage effect of the masts and rigging.
-
20.2.2 20.2.2 Typically, for square rigged sailing vessels, experience based guidance on
approximate increase in anchor mass and cable strength required is:
for vessels up to 50 metres in length, typically 50% above the requirements for a
typical motor vessel having the same total longitudinal profile area of hull and superstructure
as the square rigged sailing vessel under consideration; and
for vessels 100 metres in length and over, typically 30% above the requirements for
a typical motor vessel having the same total longitudinal profile area of hull and
superstructure as the square rigged sailing vessel under consideration.
For a square rigged sailing vessel of between 50 and 100 metres in length the increase
should be obtained by linear interpolation.
21 ACCOMMODATION
21.1 General
-
21.1.1 This section applies to vessels to which sections 21A and 21B do not apply.
-
21.1.2 An adequate standard of accommodation should be provided to ensure the comfort, recreation,
health and safety of all persons on board, due consideration should also be given
to the number of hotel and other support staff required.
-
21.1.3 Attention is drawn to the achievement of appropriate standards for means of access
and escape, lighting, heating, food preparation and storage, messing, safety of movement
about the vessel, ventilation and water services.
-
21.1.4 Generally, accommodation standards for the crew should be at least equivalent to the
standards set by the International Labour Organization conventions for crew accommodation
in merchant ships. The ILO Convention provisions should be practicable with regard
to vessels greater than 500GT. For smaller vessels, particularly sailing vessels,
the standards should be applied where possible. When it is neither reasonable nor
practicable to site crew sleeping accommodation amidships or aft, and above the deepest
waterline as required, measures taken to ensure an equivalent level of crew health
and safety should be agreed with the Administration. Sleeping accommodation with the
deckhead lining below the deepest waterline is not permitted. It is recommended that
where such accommodation is sited partially below the deepest waterline it should
be arranged such that in the event of damage to the watertight compartment in which
the accommodation space is situated, the lining should not be immersed.
-
21.1.5 Crew accommodation should not be sited within hazardous spaces.
The following standards are described by general principles which need to be expanded
to meet the requirements which relate to the use and areas of operation of particular
vessels.
21.2 Access/Escape Arrangements
Refer to 14A.3 and 14B.2.12 for details.
21.3 Lighting
An electric lighting system should be installed which is capable of supplying adequate
light to all enclosed accommodation and working spaces. The system should be designed
and installed in accordance with section 8.
21.4 Heating
As considered appropriate, an adequate heating installation should be provided.
21.5 Food Preparation, Storage and Messing
-
21.5.1 The galley floor should be provided with a non-slip surface and provide a good foothold.
-
21.5.2 All furniture and fittings in the galley should be made of a material which is impervious
to dirt and moisture. All metal parts of furniture and fittings should be rust resistant.
-
21.5.3 The ventilation in the galley should be arranged to ensure that there is an adequate
supply of fresh air and for the efficient discharge of fumes into the open air (see
also 21.7).
-
21.5.4 When a cooking appliance is gimballed it should be protected by a crash bar or other
means to prevent personal injury. Means should be provided to lock the gimballing
mechanism.
-
21.5.5 Means should be provided to allow the cook to be secured in position, with both hands
free for working, when the vessel motions threaten safe working.
-
21.5.6 Secure and hygienic storage for food and garbage should be provided.
-
21.5.7 A messing area(s) should be provided, each messing area should be large enough to
accommodate the greatest number of persons likely to use it at any one time.
21.6 Hand Holds and Grab Rails
There should be sufficient hand holds and grab rails within the accommodation to allow
safe movement around the accommodation at all times. Stairways should be specially
considered
21.7 Ventilation
-
21.7.1 Effective means of ventilation should be provided to all enclosed spaces which are
entered by personnel.
-
21.7.2 Mechanical ventilation should be provided to all accommodation spaces on vessels which
are intended to make long international voyages or operate in tropical waters. As
a minimum, mechanical ventilation should be capable of providing 6 changes of air
per hour, when all access and other openings (other than ventilation intakes) to the
spaces are closed.
-
21.7.3 Air conditioning systems are to provide a minimum of 25m3 of air per hour, per person accommodated in the ventilated space during normal operating
conditions.
-
21.7.4 Enclosed galleys are to be specially considered, and where air conditioning is not
fitted should have, as a minimum, a mechanical supply of 20 fresh air changes per
hour and a mechanical exhaust of 30 changes.
21.8 Water Services
-
21.8.1 An adequate supply of fresh drinking water should be provided and piped to convenient
positions throughout the accommodation spaces.
-
21.8.2 In addition, an emergency reserve supply of drinking water should be carried, sufficient
to provide at least 2 litres per person. The installation of fresh water making machines
and disinfection arrangements are to be to the acceptance of the Administration (for
this purpose silver ionisation or chlorination would be considered acceptable).
21.9 Sleeping Accommodation
-
21.9.1 An appropriately sized bed (bunk or cot,) should be provided for every person on board,
having a minimum inside dimension of either:
-
.1 not less than 190 centimetres by 70 centimetres, with no tapering, where the Administration
is satisfied that that this is reasonable and will not result in discomfort to the
seafarers; or
-
.2 not less than 198 centimetres in length and not less than 80 centimetres in width
over half the length of the berth. A taper is permitted from half the length of the
berth towards the foot of the berth but under no circumstances is the berth permitted
to be narrower at any point than 50 centimetres.;
-
.3 where considered appropriate, means for preventing the occupants from falling out,
should be provided.
There should be no direct access into sleeping rooms from spaces for machinery, galleys,
paint rooms or from engine, deck, and other bulk storerooms, drying rooms, communal
wash places or water closets.
-
21.9.2 In crew accommodation, wherever possible, the maximum number of persons per sleeping
room is to be two and there should be unobstructed access to at least one side of
each bed. Any increase in the maximum number of persons per sleeping room should be
agreed with the Administration.
21.10 Toilet Facilities
-
21.10.1 Adequate sanitary toilet facilities should be provided on board. The facilities should
be at least one water closet, one shower for every 8 persons or part thereof, and
one washbasin for every 6 persons or part thereof.
-
21.10.2 In vessels where a sanitary system, including a holding tank, is provided, care should
be taken to ensure that there is no possibility of fumes from the tank finding their
way back to a toilet, should the water seal at the toilet be broken.
21.11 Stowage Facilities for Personal Effects
Adequate stowage facilities for clothing and personal effects should be provided for
every person on board.
21.12 Securing of Heavy Equipment
All heavy items of equipment such as ballast, batteries, cooking stove, etc, should
be securely fastened in place. All stowage lockers containing heavy items should
have lids or doors which are capable of being securely fastened.
21A ACCOMMODATION AND RECREATIONAL FACILITIES – VESSELS OF LESS THAN 200GT CONSTRUCTED
ON OR AFTER THE DATE OF ENTRY INTO FORCE OF MLC 2006
Objective: The purpose of this section is to implement substantially equivalent arrangements
to the crew accommodation requirements of the Maritime Labour Convention 2006
to vessels built after the date of entry into force of the Convention. The aim of
the Convention is to provide a comprehensive set of global maritime labour standards
for all seafarers, including accommodation standards.
|
21A.1 General
-
21A.1.1 Vessels of less than 200GT that do not trade internationally are excepted from the
requirements of this section and should comply with Section 21.
-
21A.1.2 Accommodation should provide decent living conditions and recreational facilities
for those persons employed or engaged in any work capacity onboard. Due consideration
should be given to likely numbers of hotel and support staff onboard.
-
21A.1.3 In order to provide decent living conditions and recreational facilities the following
requirements are provided as minimum standards.
-
21A.1.4 The materials used to construct internal bulkheads, panelling and sheeting, floors
and joinings should be suitable for the purpose and conducive to ensuring a healthy
environment.
-
21A.1.5 Excessive noise and vibration should be limited within accommodation spaces, and as
far as practicable in accordance with relevant international standards. Where the
seafarers’ exposure to noise and vibration is very time limited in accommodation spaces,
alternative arrangements may be accepted.
21A.2 Access/Escape Arrangements
21A.3 Headroom
-
21A.3.1 There should be adequate and reasonable headroom for all seafarers on board taking
into consideration the size and operation of vessel. Headroom provided should not
result in discomfort to the seafarers onboard.
-
21A.3.1 For spaces where seafarers are expected to stand for prolonged periods, the minimum
headroom should be 190 centimetres. The competent authority may allow reduced height
in some locations if it does not result in discomfort to seafarers.
21A.4 Ventilation
-
21A.4.1 Effective means of ventilation should be provided to all enclosed spaces which are
entered by personnel.
-
21A.4.2 Mechanical ventilation should be provided to all accommodation spaces on vessels
which are intended to make long international voyages or operate in tropical waters.
As a minimum, mechanical ventilation should be capable of providing 6 changes of air
per hour, when all access and other openings (other than ventilation intakes) to the
spaces are closed.
-
21A.4.3 Air conditioning – recirculation of supply air may be permitted provided that
sanitary accommodation is provided with mechanical exhaust ventilation and that the
fresh air content of the supply to the accommodation is not less than:-
-
(a) 25 cubic metres per hour for each person for whom accommodation is provided; or
-
(b) the total capacity of the sanitary and any other accommodation exhaust fans, excluding
the galley, whichever is the greater.
-
21A.4.4 Enclosed galleys are to be specially considered, and where air conditioning is not
fitted should have, as a minimum, a mechanical supply of 20 fresh air changes per
hour and a mechanical exhaust of 30 changes.
-
21A.4.5 In spaces where sanitary facilities are provided there should be ventilation that
draws from the accommodation and extracts to the open air independent of the other
parts of the accommodation.
21A.5 Heating and Insulation
21A.6 Lighting
-
21A.6.1 An electric lighting system should be installed which is capable of supplying
adequate light to all enclosed accommodation and working spaces. The system should
be designed and installed in accordance with section 8.
-
21A.6.2 Seafarer’s sleeping rooms and mess rooms should be lit by natural light and provided
with adequate artificial light. Where the provision of natural light is impracticable,
adequate artificial light may be acceptable in limited areas.
21A.7 Water Services and Provision
-
21A.7.1 Hot and cold running fresh water should be available in all wash places.
-
21A.7.2 An adequate supply of fresh drinking water should be provided and piped to convenient
positions throughout the accommodation spaces.
-
21A.7.3 In addition, an emergency reserve supply of drinking water should be carried, sufficient
to provide at least 2 litres per person. The installation of fresh water making machines
and disinfection arrangements are to be to the acceptance of the Administration (for
this purpose silver ionisation or chlorination would be considered acceptable).
21A.8 Galley Facilities and Provision of Food
-
21A.8.1 Adequate food should be provided for all seafarers onboard free of charge. The provision
of food should take account of the seafarers’ religious requirements and cultural
practices, the nature and duration of the voyage, and should be suitable in respect
of quantity, nutritional value, quality and variety.
-
21A.8.2 The organisation and equipment of the catering department should be such as to permit
the provision to the seafarers of adequate, varied and nutritious meals prepared and
served in hygienic conditions. This should include as a minimum that the galley is
fitted with a means of cooking and a sink and have adequate working surface for the
preparation of food. The galley floor should be provided with a non-slip surface and
provide a good foothold.
-
21A.8.3 All furniture and fittings in the galley should be made of a material which is impervious
to dirt and moisture. All metal parts of furniture and fittings should be rust resistant.
-
21A.8.4 The ventilation in the galley should be arranged to ensure that there is an
adequate supply of fresh air and for the efficient discharge of fumes into the open
air (see also 21A.4.4).
-
21A.8.5 When a cooking appliance is gimballed it should be protected by a crash bar or other
means to prevent personal injury. Means should be provided to lock the gimballing
mechanism.
-
21A.8.6 Means should be provided to allow the cook to be secured in position, with both hands
free for working, when the vessel motions threaten safe working.
-
21A.8.7 Secure and hygienic storage for food and garbage should be provided.
-
21A.8.8 A messing area(s) should be provided, each messing area should be large enough
to accommodate the greatest number of persons likely to use it at any one time.
21A.9 Hand Holds and Grab Rails
21A.10 Sleeping Accommodation
-
21A.10.1 Sleeping accommodation should be of adequate size and properly equipped so as to ensure
reasonable comfort and to facilitate tidiness.
-
21A.10.2 There should be no direct access into sleeping rooms from spaces for machinery, galleys,
storerooms, drying rooms, or communal sanitary areas.
-
21A.10.3 In seafarer accommodation, wherever possible, the maximum number of persons per sleeping
room is to be two and there should be unobstructed access to at least one side of
each bed. Any increase in the maximum number of persons per sleeping room should be
agreed with the Administration.
-
21A.10.4 Sleeping accommodation should be situated or equipped, as practicable, so as to provide
appropriate levels of privacy for men and for women.
-
21A.10.5 Berths for seafarers must have a minimum inside dimension of either:
-
.1 not less than 190 centimetres by 70 centimetres, with no tapering, where it is satisfied
that that this is reasonable and will not result in discomfort to the seafarers; or
-
.2 not less than 198 centimetres in length and not less than 80 centimetres in width
over half the length of the berth. A taper is permitted from half the length of the
berth towards the foot of the berth but under no circumstances is the berth permitted
to be narrower at any point than 50 centimetres.
-
21A.10.6 Where considered appropriate, means for preventing the occupants from falling out,
should be provided.
-
21A.10.7 Sleeping rooms should be situated above the load line/freeboard mark amidships or
aft (or the maximum loaded displacement where no load line/freeboard mark is provided),
but in no case forward of the collision bulkhead.
-
21A.10.8 Where it is not possible to provide sleeping accommodation above the load line/freeboard
mark (or the maximum loaded displacement where no load line/freeboard mark is provided)
as required by 21A.10.7, there should be an alarm fitted to provide early warning
of flooding that alerts occupants of the sleeping accommodation and provides them
with sufficient time to escape from the accommodation.
21A.11 Sanitary Facilities
-
21A.11.1 There must be at least one set of sanitary facilities for each 6 seafarers onboard,
separated from the rest of the accommodation. Each set of sanitary facilities should
include one shower or one tub, one wash basin and one toilet. Each set of sanitary
facilities must be provided with a door that is lockable. Where reasonable and practicable
there should be separate sanitary facilities provided for men and for women.
-
21A.11.2 In vessels where a sanitary system, including a holding tank, is provided, care should
be taken to ensure that there is no possibility of fumes from the tank finding their
way back to a toilet, should the water seal at the toilet be broken.
21A.12 Mess Rooms
-
21A.12.1 Mess rooms should be of adequate size and comfort and properly furnished and equipped
(including ongoing facilities for refreshment), taking account of the number of seafarers
likely to use them at any one time. It may be that the mess will be a shared facility
for seafarers and passengers; this should be subject to agreement by the Administration.
21A.13 Recreational Facilities
-
21A.13.1 Appropriate seafarers’ recreational facilities, amenities and services, as adapted
to meet the special needs of seafarers who must live and work onboard, should be provided.
-
21A.13.2 All vessels should have a space or spaces on open deck to which the seafarers can
have safe access when off duty, which are of adequate area having regard to the size
of the ship and the number of seafarers onboard, and are protected from the elements.
Due consideration should be given to any areas of deck which may be considered as
posing a safety risk to seafarers. Such spaces may be shared with the passengers onboard.
21A.14 Stowage Facilities for Personal Effects
21A.15 Machinery Space Boundaries
-
21A.15.1 Where machinery spaces are adjacent to accommodation spaces, the boundaries should
be designed to be gas tight. The requirement to be gas-tight is taken to mean that
bulkheads should be so constructed as to prevent ingress of water and noxious gases
into adjacent cabins as far as is reasonable and practicable to do so.
-
21A.15.2 Machinery space boundaries must retain any liquids which may leak from the equipment
within the machinery space.
21A.16 Securing of Heavy Equipment
-
21A.16.1 All heavy items of equipment such as ballast, batteries, cooking stove, etc, should
be securely fastened in place. All stowage lockers containing heavy items should
have lids or doors which are capable of being securely fastened.
21A.17 Protection from Mosquitoes
21A.18 Master’s Inspections
-
21A.18.1 There should be weekly documented inspections carried out on board vessels, by or
under the authority of the Master, with respect to:
-
.1 supplies of food and drinking water;
-
.2 all spaces and equipment used for the storage and handling of food and drinking water;
-
.3 galley and other equipment used for the preparation and service of meals; and
-
.4 that seafarer accommodation is clean, decently habitable and maintained in a good
state of repair.
-
21A.18.2 The results of each inspection should be recorded and made available for review.
21B ACCOMMODATION – VESSELS ≥200GT CONSTRUCTED ON OR AFTER THE DATE OF ENTRY INTO
FORCE OF MLC 2006
Objective: The purpose of this section is to implement substantially equivalent arrangements
to the seafarer accommodation requirements of the Maritime Labour Convention 2006
to vessels built after the date of entry into force of the Convention. There are alternative
arrangements for vessels of traditional design and vessels under 200GT which do not
trade internationally. The aim of the Convention is to provide a comprehensive set
of global maritime labour standards for all seafarers, including accommodation standards
|
21B.1 Introduction
-
21B.1.1 This section applies to vessels of 200GT or over, the keel of which was laid or was
at a similar stage of construction, on or after the date of entry into force of the
MLC 2006.
-
21B.1.2 When agreed with the Administration, vessels which are of traditional build and are
true replicas of traditionally designed yachts, which includes wooden yachts, ‘J Class’
yachts and other yachts of similar design where their traditional character is incompatible
with the detailed accommodation requirements, particularly with regard to cabin size,
are excepted from the requirements of this section and should comply with Section
21.
21B.2 General
-
21B.2.1 Accommodation should provide decent living conditions and recreational facilities
for all seafarers onboard the vessel. Due consideration should be given to likely
numbers of hotel and support staff onboard
-
21B.2.2 In order to provide decent living conditions and recreational facilities the following
requirements are provided as minimum standards.
-
21B.2.3 The materials used to construct internal bulkheads, panelling and sheeting, floors
and joinings should be suitable for the purpose and conducive to ensuring a healthy
environment. All relevant health and safety standards should be observed.
-
21B.2.4 The accommodation should be adequately insulated; proper lighting and sufficient
drainage should be provided.
-
21B.2.5 There should be no direct openings into sleeping rooms from machinery spaces, galleys,
storerooms, drying rooms or communal sanitary areas. That part of a bulkhead separating
such places from sleeping rooms and external bulkheads should be efficiently constructed
of steel or other approved material and be watertight and gas-tight. The requirement
to be watertight and gas-tight is taken to mean that bulkheads should be so constructed
as to prevent ingress of water, cooking smells, and noxious gases into adjacent cabins.
21B.3 Headroom
-
21B.3.1 There should be adequate headroom in all seafarer accommodation. The minimum permitted
headroom in all seafarer accommodation where full and free movement is necessary should
be not less than 203 centimetres. Some limited reduction in headroom in any space,
or part of any space, in such accommodation may be permitted, provided this is reasonable
and does not result in discomfort to the seafarer and is agreed with the Administration.
21B.4 Access/Escape arrangements
21B.5 Lighting
21B.6 Heating
21B.7 Ventilation
-
21B.7.1 Sleeping rooms and mess rooms should be adequately ventilated. Vessels, except
those regularly operating in areas where temperate climatic conditions do not require
this, should be equipped with air conditioning for seafarer accommodation, for any
separate radio room and for any centralised machinery control room. All sanitary spaces
should have ventilation that draws from the accommodation and extracts to the open
air, independently of any other part of the accommodation.
-
21B.7.2 Mechanical ventilation should be provided to all accommodation spaces on vessels
which are intended to make long international voyages or operate in tropical waters.
As a minimum, mechanical ventilation should be capable of providing 6 changes of air
per hour, when all access and other openings (other than ventilation intakes) to the
spaces are closed.
-
21B.7.3 Air conditioning – recirculation of supply air may be permitted provided that
sanitary accommodation is provided with mechanical exhaust ventilation and that the
fresh air content of the supply to the accommodation is not less than:-
-
(a) 25 cubic metres per hour for each person for whom accommodation is provided; or
-
(b) the total capacity of the sanitary and any other accommodation exhaust fans, excluding
the galley, whichever is the greater.
21B.8 Sleeping Accommodation
21B.8.1 General
-
21B.8.1.1 The sleeping accommodation should meet 21B.8.2 (the requirements for sleeping
accommodation of the Maritime Labour Convention 2006 for vessels less than 3000GT).
Where this is not practicable the sleeping accommodation should meet the substantially
equivalent requirements of 21B.8.3 for vessels of 200GT and over and less than 500GT,
and 21B.8.4 for vessels of 500GT and over and less than 1250GT. Vessels of 3000 GT
and more should comply with the requirements of 21B.8.5.
-
21B.8.1.2 Sleeping accommodation should be of adequate size and properly equipped so as to ensure
reasonable comfort and to facilitate tidiness.
21B.8.2 Sleeping Accommodation – for vessels up to 3000 GT.
-
21B.8.2.1 21B.8.2.1 Sleeping rooms should be situated above the deepest waterline amidships
or aft. Where this is impractical, sleeping rooms may be located in the fore part
of the vessel, but in no case forward of the collision bulkhead nor immediately beneath
working alleyways4.
-
21B.8.2.2 When it is neither reasonable nor practicable to site seafarer sleeping accommodation
amidships or aft, and above the deepest waterline as required, measures taken to ensure
an equivalent level of seafarer health and safety should be agreed with the Administration.
Where the sole of the sleeping accommodation is below the deepest waterline amidships,
a bilge flooding alarm should be provided in the sleeping accommodation to provide
early warning of flooding to that compartment. Sleeping accommodation with the deck
head lining below the deepest intact waterline is not permitted. In addition, for
vessels other than short range yachts, where such accommodation is sited partially
below the deepest waterline it should be arranged such that in the event of damage
to the watertight compartment in which the accommodation space is situated, the deck
head lining should not be immersed. Satisfactory arrangements should be made for lighting
and ventilation.
-
21B.8.2.3 Separate sleeping rooms should be provided for men and for women.
-
21B.8.2.4 A separate berth for each seafarer should in all circumstances be provided. The minimum
inside dimensions of a berth should not be less than 198 centimetres in length and
not less than 80 centimetres in width over half the length of the berth. A taper is
permitted from half the length of the berth towards the foot of the berth but under
no circumstances is the berth permitted to be narrower at any point than 50 centimetres.
-
21B.8.2.5 The master, the chief engineer and the chief navigating officer should have, in addition
to their sleeping rooms, an adjoining sitting room, day room or equivalent additional
space. Where this not practicable, an alternative comfortable shared sitting area
may be provided. Such a space should allow such officers to meet privately, or to
meet with other seafarers privately. The Navigating Bridge, if suitably fitted, may
be considered if it is available for this exclusive use when the ship is not engaged
in navigation. When the ship is engaged in navigation, the watchkeepers should not
be distracted.
-
21B.8.2.6 Every seafarer is to be provided with a clothes locker of ample space (minimum 475
litres) and a drawer or equivalent space of not less than 56 litres. If the drawer
is incorporated in the clothes locker then the combined minimum volume of the clothes
locker should be 500 litres. The locker should be fitted with a shelf and be able
to be locked by the seafarer so as to ensure security and maintain privacy. Where
the total required volume cannot be provided within the cabin, the Administration
may consider accepting secure facilities for the individual elsewhere within the seafarer
accommodation, provided that within the cabin a minimum of 300 litres storage space
is provided for each individual seafarer.
-
21B.8.2.7 Sleeping rooms should be provided with a table or desk, which may be of the fixed,
drop-leaf or slide-out type or other alternative table, and with comfortable seating
accommodation as necessary.
-
21B.8.2.8 In calculating the floor area of sleeping rooms, spaces occupied by berths, lockers,
seats, chests of drawers and other furniture should be included in the area but spaces
which by reason of their small size or irregular shape cannot accommodate furniture
and do not contribute to the area available for free movement should not be included.
Where a berth or other fixed furniture is situated at the side of the vessel the projected
area (to floor level) of such berths or fixed furniture may be used in the calculation
of the sleeping room area.
-
21B.8.2.9 To the extent possible an individual sleeping room should be provided for each seafarer,
the floor area of which should not be less than 4.5 square metres. This minimum floor
area may include en-suite sanitary facilities where provided.
-
21B.8.2.10 Where it is not practical to provide single occupancy cabins, sleeping rooms to be
occupied by a maximum of two seafarers may be accepted, provided that the floor area
of such sleeping rooms is not less than 7 square metres. The floor area may include
en suite sanitary facilities, if provided.
-
21B.8.2.11 The floor area for sleeping rooms for seafarers who are officers on vessels where
an adjoining sitting room, day room or equivalent additional space are provided should
not be less than 4.5 square metres per seafarer. This area may include en-suite sanitary facilities. It is not expected that seafarers who are officers
should be required to share a cabin.
-
21B.8.2.12 The floor area for sleeping rooms for seafarers who are officers on vessels where
no adjoining sitting room, day room or equivalent additional space are provided should
not be less than 7.5 square metres per seafarer. This area may include en-suite sanitary facilities. It is not expected that seafarers who are officers
should be required to share a cabin.
21B.8.3 Sleeping Accommodation – Equivalent arrangements to the Maritime Labour Convention
2006 for vessels of 200GT and over and less than 500GT.
-
21B.8.3.1 Sleeping rooms should be situated above the deepest waterline amidships or aft where
practicable. Where this is impractical, sleeping rooms may be located in the fore
part of the vessel, but in no case forward of the collision bulkhead nor immediately
beneath working alleyways5.
-
21B.8.3.2 When it is neither reasonable nor practicable to site seafarer sleeping accommodation
amidships or aft, and above the deepest waterline as required, measures taken to ensure
an equivalent level of seafarer health and safety should be agreed with the Administration.
Where the sole of the sleeping accommodation is below the deepest waterline amidships,
a bilge flooding alarm should be provided in the cabin to provide early warning of
flooding to that compartment. Sleeping accommodation with the deck head lining below
the deepest intact waterline is not permitted. In addition, for vessels other than
short range yachts, where such accommodation is sited partially below the deepest
waterline it should be arranged such that in the event of damage to the watertight
compartment in which the accommodation space is situated, the deck head lining should
not be immersed. Satisfactory arrangements should be made for lighting and ventilation.
-
21B.8.3.3 Separate sleeping rooms should be provided for men and for women.
-
21B.8.3.4 A separate berth for each seafarer should in all circumstances be provided. The minimum
inside dimensions of a berth should be at least 198 centimetres by 80 centimetres.
Narrower berths may be permitted in either (a) sleeping rooms occupied by only one
seafarer or (b) sleeping rooms where en-suite sanitary facilities are provided – in
such cases the minimum inside dimensions of a berth should not be less than 198
centimetres in length and not less than 80 centimetres in width over half the
length of the berth. A taper is permitted from half the length of the berth towards
the foot of the berth but under no circumstances is the berth permitted to be narrower
at any point than 50 centimetres.
-
21B.8.3.5 Where practical, the master, the chief engineer and the chief navigating officer should
have, in addition to their sleeping rooms, an adjoining sitting room, day room or
equivalent additional space. Where this not practicable, an alternative comfortable
shared sitting area may be provided. Such a space should allow such officers to meet
privately, or to meet with other seafarers privately. The Navigating Bridge, if suitably
fitted, may be considered if it is available for this exclusive use when the ship
is not engaged in navigation. When the ship is engaged in navigation, the watchkeepers
should not be distracted.
-
21B.8.3.6 Every seafarer is to be provided with a clothes locker of ample space (minimum 475
litres) and a drawer or equivalent space of not less than 56 litres. If the drawer
is incorporated in the clothes locker then the combined minimum volume of the clothes
locker should be 500 litres. The locker should be fitted with a shelf and be able
to be locked by the seafarer so as to ensure security and maintain privacy. Where
the total required volume cannot be provided within the cabin, the Administration
may consider accepting secure facilities for the individual elsewhere within the seafarer
accommodation, provided that within the cabin a minimum of 300 litres storage space
is provided for each individual seafarer.
-
21B.8.3.7 Sleeping rooms should be provided with a table or desk, which may be of the fixed,
drop-leaf or slide-out type or other alternative table, and with comfortable seating
accommodation as necessary.
-
21B.8.3.8 Where a single berth seafarer’s cabin without en-suite sanitary facilities is provided
it should have a floor area of not less than 3.6 square metres.
-
21B.8.3.9 A single berth seafarer’s cabin provided with en-suite sanitary facilities, should
have a floor area of not less than 4.5 square metres. En-suite sanitary facilities
are considered to compensate for reduced floor area and form part of the floor area.
-
21B.8.3.10 Sleeping rooms occupied by two seafarers without en-suite sanitary facilities should
have a floor area of not less than 7 square metres.
-
21B.8.3.11 A cabin occupied by two seafarers where en-suite sanitary facilities are provided
should have a minimum floor area of 6.2 square metres. En-suite sanitary facilities
are considered to compensate for reduced floor area and form part of the floor area.
-
21B.8.3.12 Where the reduced floor areas in 21B.8.3.8 to 21B.8.3.11 are adopted, the free floor
area in the sleeping accommodation should be at least 1.45 square metres per seafarer
to provide for sufficient comfortable movement.
-
21B.8.3.13 Where the requirement of 21B.8.3.12 is not practical due to the hull shape or hull
stiffening, but the arrangements in the cabin allow for a free movement of the upper
part of the body equivalent to an area of 1.45 square metres, a reduced free floor
area may be provided with the Administration’s agreement, but should not be less than
1 square metre per seafarer.
-
21B.8.3.14 Where the requirements of 21B.8.3.13 are accepted by the Administration, the en-suite
sanitary facilities should be large enough to allow for the facilities to be used
with the door closed and would not be expected to have a floor area of less than 1.2
square metres. Where the floor area of the en-suite sanitary facilities provided is
greater than 1.2 square metres, the free floor area of the cabin may be reduced accordingly,
but should never be less than 1 square metre per seafarer.
21B.8.4 Sleeping Accommodation – Equivalent arrangements to the Maritime Labour Convention
2006 for vessels of 500GT and over and less than 1250GT.
-
21B.8.4.1 Sleeping rooms should be situated above the deepest waterline amidships or aft where
practicable. Where this is impractical, sleeping rooms may be located in the fore
part of the vessel, but in no case forward of the collision bulkhead nor immediately
beneath working alleyways6.
-
21B.8.4.2 When it is neither reasonable nor practicable to site seafarer sleeping accommodation
amidships or aft, and above the deepest waterline as required, measures taken to ensure
an equivalent level of seafarer health and safety should be agreed with the Administration.
Where the sole of the sleeping accommodation is below the deepest waterline amidships,
a bilge flooding alarm should be provided in the cabin to provide early warning of
flooding to that compartment. Sleeping accommodation with the deck head lining below
the deepest intact waterline is not permitted. In addition, where such accommodation
is sited partially below the deepest waterline it should be arranged such that in
the event of damage to the watertight compartment in which the accommodation space
is situated, the deck head lining should not be immersed. Satisfactory arrangements
should be made for lighting and ventilation.
-
21B.8.4.3 Separate sleeping rooms should be provided for men and for women.
-
21B.8.4.4 A separate berth for each seafarer should in all circumstances be provided. The minimum
inside dimensions of a berth should be at least 198 centimetres by 80 centimetres.
Narrower berths may be permitted in either (a) sleeping rooms occupied by only one
seafarer or (b) sleeping rooms where en-suite sanitary facilities are provided – in
such cases the minimum inside dimensions of a berth should not be less than 198
centimetres in length and not less than 80 centimetres in width over half the
length of the berth. A taper is permitted from half the length of the berth towards
the foot of the berth but under no circumstances is the berth permitted to be narrower
at any point than 50 centimetres.
-
21B.8.4.5 Where practical, the master, the chief engineer and the chief navigating officer should
have, in addition to their sleeping rooms, an adjoining sitting room, day room or
equivalent additional space. If an adjoining sitting room, day room or equivalent
additional space is provided the minimum floor area of the cabin should not be less
than 4.5 square metres. If there is no dayroom provided see 21B.8.4.14.
-
21B.8.4.6 Every seafarer is to be provided with a clothes locker of ample space (minimum 475
litres) and a drawer or equivalent space of not less than 56 litres. If the drawer
is incorporated in the clothes locker then the combined minimum volume of the clothes
locker should be 500 litres. The locker should be fitted with a shelf and be able
to be locked by the seafarer so as to ensure security and maintain privacy. Where
the total required volume cannot be provided within the cabin, the Administration
may consider accepting secure facilities for the individual elsewhere within the seafarer
accommodation, provided that within the cabin a minimum of 300 litres storage space
is provided for each individual seafarer.
-
21B.8.4.7 Sleeping rooms should be provided with a table or desk, which may be of the fixed,
drop-leaf or slide-out type or other alternative table, and with comfortable seating
accommodation as necessary.
-
21B.8.4.8 Where a single berth seafarer’s cabin without en-suite sanitary facilities is provided
it should have a floor area of not less than 3.6 square metres.
-
21B.8.4.9 A single berth seafarer’s cabin provided with en-suite sanitary facilities, should
have a floor area of not less than 4.5 square metres. En-suite sanitary facilities
are considered to compensate for reduced floor area and form part of the floor area.
-
21B.8.4.10 Sleeping rooms occupied by two seafarers without en-suite sanitary facilities should
have a floor area of not less than 7 square metres.
-
21B.8.4.11 Single occupancy cabins for seafarers who are officers for whom no adjoining sitting
room, day room or equivalent additional space are provided should be not less than
4.5 square metres for a vessel of 500GT and not less than 7.5 square metres for vessels
of 1250GT and over. For a vessel of intermediate gross tonnage the floor area should
be determined by linear interpolation, as shown in Figure 21B.1 below. En-suite sanitary
facilities are considered to compensate for reduced floor area and form part of the
floor area.
Figure 21B.1 – Cabin Floor Areas – Single Occupancy
-
21B.8.4.12 Floor areas of double occupancy cabins with en-suite sanitary facilities for seafarers
who are officers for whom no adjoining sitting room, day room or equivalent additional
space are provided should be not less than 6.2 square metres for a vessel of 500GT
and not less than 15 square metres for vessels of 1150GT and over. For a vessel of
intermediate gross tonnage the floor area should be determined by linear interpolation,
as shown in Figure 21B.2 below. For seafarers who are not officers, the floor area
of a double occupancy cabin with en-suite sanitary facilities should increase at the
same rate as cabins provided for seafarers who are officers until it is 7 square metres.
Figure 21B.2 – Cabin Floor Areas – Double Occupancy
-
21B.8.4.13 Officer’s cabins with a floor area less than 7.5 square metres should be provided
with televisions and other suitable electronic audio-visual equipment.
-
21B.8.4.14 Where adjoining sitting rooms, day rooms or other equivalent additional spaces are
not provided in accordance with 21B.8.4.11 an additional space providing a comfortable
shared sitting area for such officers should be provided with a floor area of at least
1.5 square metres per officer. Such a space should allow the seafarers who are officers
to meet privately, or the seafarers who are officers to meet with other seafarers
privately. The wheelhouse, if suitably fitted, may be considered if it is available
for this exclusive use when the vessel is not engaged in navigation. When the ship
is engaged in navigation, the watchkeepers should not be distracted.
21B.8.5 Sleeping Accommodation – Yachts of 3000 GT or more
Vessels of 3000 GT or more constructed on or after the Maritime Labour Convention,
2006 enters into force should comply with the full requirements of standard A3.1 of
the Maritime Labour Convention 2006.
21B.9 Mess Rooms
-
21B.9.1 Mess rooms should be located apart from the sleeping rooms to avoid disturbing those
persons sleeping and as close as practicable to the galley. Mess rooms should be of
adequate comfort and properly furnished and equipped (including ongoing facilities
for refreshment), taking account of the number of seafarers likely to use them at
any one time. Mess rooms for seafarers who are officers and other seafarers may be
separate or common, as appropriate.
-
21B.9.1 Where the substantially equivalent arrangements in 21B.8.3 and 21B.8.4 are used,
the floor area of mess rooms for seafarers should not be less than 1.5 square metres
per person of the planned seating capacity.
21B.10 Galley Areas, Food Preparation, Storage, and Provision of Food
-
21B.10.1 Adequate food should be provided for all seafarers onboard free of charge. The provision
of food should take account of the seafarers’ religious requirements and cultural
practices, the nature and duration of the voyage, and should be suitable in respect
of quantity, nutritional value, quality and variety.
-
21B.10.2 The organisation and equipment of the catering department should be such as to permit
the provision to the seafarers of adequate, varied and nutritious meals prepared and
served in hygienic conditions. This should include as a minimum that the galley is
fitted with a means of cooking and a sink and have adequate working surface for the
preparation of food. The galley floor should be provided with a non-slip surface and
provide a good foothold.
-
21B.10.3 All furniture and fittings in the galley should be made to be impervious to dirt and
moisture. All metal parts of furniture and fittings should be rust resistant.
-
21B.10.4 The ventilation in the galley should be arranged to ensure that there is an adequate
supply of fresh air and for the efficient discharge of fumes into the open air. Air
conditioning systems are to provide a minimum of 25 cubic metres of air per hour,
per person working in the ventilated space during normal operating conditions. Enclosed
galleys are to be specially considered, and where air conditioning is not fitted should
have, as a minimum, a mechanical supply of 20 fresh air changes per hour and a mechanical
exhaust of 30 changes per hour.
-
21B.10.5 When a cooking appliance is gimballed it should be protected by a crash bar or other
means to prevent personal injury. Means should be provided to lock the gimballing
mechanism.
-
21B.10.6 Means should be provided to allow the person cooking to be secured in position, with
both hands free for working, when the vessel motions threaten safe working. Secure
and hygienic storage for food and garbage should be provided.
21B.11 Water Services
-
21B.11.1 An adequate supply of fresh drinking water should be provided and piped to convenient
positions throughout the accommodation spaces.
-
21B.11.2 In addition, an emergency reserve supply of drinking water should be carried, sufficient
to provide at least 2 litres per person the vessel is certificated to carry. The installation
of fresh water making machines and disinfection arrangements are to be to the acceptance
of the Administration – for this purpose silver ionisation or chlorination would be
considered acceptable.
21B.12 Sanitary Facilities
-
21B.12.1 A minimum of one toilet, one wash basin and one tub or shower or both for every six
seafarers or less who do not have en-suite sanitary facilities should be provided
at a convenient location.
-
21B.12.2 Separate sanitary facilities should be provided for men and for women. In respect
of sanitary facilities for men and for women, vessels should be provided with a minimum
of 2 sets of sanitary facilities for the first two seafarers onboard plus an additional
set of sanitary facilities for every additional 6 seafarers.
-
21B.12.3 Where a sleeping room is provided with en-suite sanitary facilities those facilities
should include a minimum of one toilet, one wash basin and one tub or shower or both.
-
21B.12.4 Where private or semi-private facilities cannot be provided, all seafarers should
have convenient access on the vessel to sanitary facilities meeting minimum standards
of health and hygiene and reasonable standards of comfort. Hot and cold running fresh
water should be available in all wash places.
-
21B.12.5 Sanitary facilities within easy access of the wheelhouse, and the machinery space
or near the engine room control centre should be provided where practical.
-
21B.12.6 Every sleeping room should be provided with a washbasin with hot and cold running
fresh water, except where such a washbasin is situated in the en-suite sanitary facilities
provided.
21B.13 Hospital accommodation
-
21B.13.1 Vessels carrying 15 or more seafarers and engaged in a voyage of more than three days’
duration should provide separate hospital accommodation to be used exclusively for
medical purposes. This may be a treatment room that also meets the requirements for
hospital accommodation. Hospital accommodation should be designed to facilitate the
giving of medical first aid and to help prevent the spread of infectious diseases.
-
21B.13.2 It is recommended that the arrangement of the entrance, berths, lighting, ventilation,
heating and water supply should be designed to ensure comfort and facilitate the treatment
of occupants.
-
21B.13.3 Sanitary facilities should be provided for the exclusive use of the occupants of the
hospital accommodation, either as part of the accommodation or in close proximity
thereto. Such sanitary facilities should comprise a minimum of one toilet, one washbasin
and one shower or tub.
-
21B.13.4 Short-range yachts and other vessels that remain within 60 miles of the coast are
exempt from 21B.13.1. In cases where such vessels are engaged on voyages of more than
three days duration, for example on re-positioning trips, an en-suite cabin should
be designated exclusively for medical purposes. Such a cabin should be designed to
facilitate (when in hospital mode) the giving of medical first aid and to help prevent
the spread of infectious diseases and it is recommended that the arrangement of the
entrance, berths, lighting, ventilation, heating and water supply should be designed
to ensure comfort and facilitate the treatment of occupants.
21B.14 Laundry Facilities
21B.15 Offices
21B.16 Other Provisions
-
21B.16.1 A space or spaces should be provided on open deck for the recreation of seafarers
to which seafarers can have access when off duty. This should have a total floor area
of 1.5 square metres per person for the greatest number of seafarers likely to use
the space at any one time.
-
21B.16.1 Vessels regularly trading to and within mosquito infested ports should be fitted with
appropriate devices to protect seafarers from mosquitos, as agreed by the Administration.
-
21B.16.1 Appropriate seafarers’ recreational facilities, amenities and services, as adapted
to meet the special needs of seafarers who live and work onboard should be provided.
21B.17 Master’s Inspections
-
21B.17.1 There should be weekly documented inspections carried out on board vessels, by or
under the authority of the Master, with respect to:
-
.1 supplies of food and drinking water;
-
.2 all spaces and equipment used for the storage and handling of food and drinking water;
-
.3 galley and other equipment used for the preparation and service of meals; and
-
.4 that seafarer accommodation is clean, decently habitable and maintained in a good
state of repair.
The results of each inspection should be recorded and made available for review.
21B.18 Hand Holds and Grab Rails
21B.19 Securing of Heavy Equipment
-
21B.19.1 All heavy items of equipment such as ballast, batteries, cooking stove, etc, should
be securely fastened in place. All stowage lockers containing heavy items should
have lids or doors which are capable of being securely fastened.
21B.20 Sailing Vessels
-
21B.20.1 The requirements of Chapter 21B apply to sailing vessels in the same way as they do
to motor vessels.
-
21B.20.2 Where the sailing vessel is below 1500GT the variations described in 21B.20.3 and
21B.20.4 may be adopted.
-
21B.20.3 On a case by case basis where due to the number of seafarers and passengers on a sailing
vessel, for example a sail training vessel or a sailing vessel used for racing, it
is not possible to meet the equivalent arrangements of 21B.8.3.12 (minimum of 1 square
metre free floor area per seafarers), seafarers should have no worse accommodation
arrangements than the passengers.
-
21B.20.4 Where it is not possible to meet the requirements of 21B.8.4.14 due to there not being
a wheelhouse, an additional space that provides privacy for the seafarers who are
officers, such as a spare cabin, may be provided to the satisfaction of the Administration.
Such a space should allow the seafarers who are officers to meet privately, or the
seafarers who are officers to meet with other seafarers privately.
22 PROTECTION OF PERSONNEL
22.1 Deckhouses and Superstructures
The structural strength of any deckhouse or superstructure should comply with the
requirements of one of the Classification Societies listed in the National Annex,
as appropriate to the vessel and its areas of operation.
22.2 Bulwarks and Guardrails
-
22.2.1 Bulwarks and/or guardrails on all accessible decks should be 1000mm high except that
on vessels built to 1959 Load Line Rules these may be 915mm high. Any opening should
not exceed 380mm. Where no bulwarks are fitted, or bulwark height is less than 230mm,
the lowest opening should not exceed 230mm. They should be supported at intervals
not exceeding 2.2 metres. Intermediate courses of rails or wires should be evenly
spaced.
-
22.2.2 Satisfactory means (in the form of guard rails, life lines, gangways or underdeck
passages, etc.) should be provided for the protection of the crew in getting to and
from their quarters, the machinery space and all other areas used in the necessary
work of the craft.
-
22.2.3 Where the function of the vessel would be impeded by the provision of bulwarks and/or
guard rails complying with 22.2.1, alternative proposals detailed to provide equivalent
safety for persons on deck should be submitted to the Administration for approval.
22.3 Safe Work Aloft, Overside, and on the Bowsprit of Sailing Vessels
-
22.3.1 When access to the rig, bowsprit, or overside working is required, provision should
be made to enable people to work safely, in accordance with national standards, see
National Annex.
-
22.3.1 The arrangements provided should be based on established safe working practices for
the type of vessel. The arrangements may include but not be limited to:
-
.1 safety nets below the bowsprit;
-
.2 safety grab rails or jackstays (metal or wire) fixed along the bowsprit to act as
handholds and strong points for safety harnesses;
-
.3 mandatory use of safety harnesses aloft, overside, (refer to national annex) and for
work on the bowsprit;
-
.4 sufficient footropes and horses in wire (or rope) permanently rigged to enable seamen
to stand on them whilst working out on the yards or on the bowsprit;
-
.5 safety jackstays (metal or wire) fixed along the top of the yards, to provide handholds
and act as strong points for safety harnesses;
-
.6 means of safely climbing aloft, such as:
-
(i) fixed metal steps or ladders attached to the mast; or
-
(ii) traditional ratlines (rope) or, rattling bars (wood/steel), fixed across the shrouds
to form a permanent ladder.
22.4 Personal Clothing
It should be the responsibility of an owner/managing agent/skipper to advise that
the following requirements for items of personal clothing should be met:
-
.1 Each person on board a vessel should have protective clothing appropriate to the prevailing
air and sea temperatures.
-
.2 Each person on board a vessel should have footwear having non-slip soles, to be worn
on board.
22.5 Noise
Attention is drawn to the IMO Code on Noise Levels on Board Ships, Resolution A.468(XII),
published 1982.
-
22.5.1 Vessels covered by this Code should meet the recommendations so far as is reasonable
and practicable.
-
22.5.2 The IMO Code on Noise Levels on Board Ships promotes the control of noise within the
framework of internationally agreed guidelines, whilst recommending methods of measuring
noise at listening posts.
-
22.5.3 For safe navigation, it is important that sound signals and VHF communications can
be heard, at the navigating position in normal operating conditions.
-
22.5.4 For machinery spaces, workshops and stores which are manned either continuously or
for lengthy periods, the recommended limits are 90dB(A) for machinery spaces and 85dB(A)
for workshops and stores.
For machinery spaces which are not intended to be continuously manned or are attended
for short periods only, the recommended limits are 110dB(A).
The limits have been set from hearing damage risk considerations and the use of suitable
ear protectors.
-
22.5.5 To indicate the need to wear ear protectors, safety signs, signs with symbols and
supplementary warning notices should be displayed at all entrances to spaces in which
the noise level exceeds 85dB(A). See National Annex.
22.6 Lifts
Personnel lift installations should be appropriately designed and constructed, installed
and tested by a competent person.
Designs should be submitted at an early stage of construction. Recognised international
standards such as BS EN 81 should be considered but the following gives a minimum
standard that should be provided:
-
1. Structural fire protection requires lift shaft within an ‘A’ class division as per
section 14B.2.6. Where the lift shaft is fitted within a stairway enclosure there
is no need for ‘A’ class divisions between the lift and the staircase.
-
2. Construction and installation for marine use should be supported by a certificate
from a Classification Society or manufacturer and include a relevant load test.
-
3. Lift should comprise an enclosed capsule.
-
4. A suitable means of escape from the capsule and lift shaft should be provided.
-
5. Mains and emergency power to be provided, where necessary to comply with item 4.
-
6. Emergency lighting to be provided.
-
7. An internal alarm and telephone to be provided.
-
8. Normal operation should ensure lift only stops at each deck.
-
9. ‘Not to be used in case of fire’ sign to be posted within.
Reference standards include:
BS EN 81 series – Safety rules for the construction and installation of lifts BS 5655
series – Lifts and service lifts
23 MEDICAL STORES
A vessel should carry medical stores as required by the Administration.
Medical training requirements for members of the complement of the vessel are given
in the Manning Section of the National Annex.
24 SHORE-SHIP TRANSFER OF PERSONNEL
24.1 Tenders
-
24.1.1 When a vessel carries a rigid or inflatable tender, it should be fit for its intended
use, regularly inspected by the owner/managing agent, and maintained in a safe condition.
-
24.1.2 Safety equipment should be provided in the tender as appropriate to its intended range
and area of operation.
-
24.1.3 Each tender should be clearly marked with the number of persons (mass 75 kg) that
it can safely carry, and the name of the parent vessel.
-
24.1.4 In the case of petrol-engined tenders, see section 14 for the safety requirements
for the carriage of petrol.
24.2 Helicopters
-
24.2.1 When provision is made for helicopter operations to or from the vessel, the helicopter
landing area should be located on an appropriate area of the weather or superstructure
deck, or on a purpose built landing area permanently attached to the vessel or structure,
providing:
-
.1 the structural strength of the helicopter landing area is designed and constructed
according to Classification Society rules on helicopter landing areas for vessels
and a Certificate of Compliance is issued by the relevant Classification Society;
-
.2 all other considerations such as landing area size, means of access, obstacle protected
surfaces (sector clearance zones), lighting, and marking should be in accordance with
Annex 6 of this Code with a Helicopter Landing Area Certificate issued by the Aviation
Inspection Body;
-
.3 the requirements for helicopter facilities in SOLAS II-2 are complied with in full.
Fire suits provided for helideck crew should be of EN 469 standard;
-
.4 helicopter operations to / from the vessel are restricted to within the weather, pitch,
roll, and heave limits for the vessel as defined where appropriate in the relevant
operating rules, and / or in the rotorcraft flight manual (RFM) and /or by the Aviation
Inspection Body;
-
.5 the helicopter landing area is designed for the largest helicopter which it is intended
to use; and
-
.6 the operational procedures for the vessel fully reflect the above.
-
24.2.2 If it is proposed to provide hangar and/or refuelling facilities for a helicopter
whilst it is on board the vessel, prior approval should be sought from the Administration.
Such facilities should be arranged in accordance with Annex 6 Section 7 and/or 8 of
this Code.
-
24.2.3 In order to meet the full safe landing area size requirement in Annex 6 of this Code,
the out-board edges of the landing area may be engineered to retract or fold to a
closed position when the landing area is not in use providing the overall safe landing
area, including the retractable or movable sides, when fully deployed, provides the
minimum load bearing area specified.
-
24.2.3.1 The minimum safe landing area dynamic load bearing capability should be 2.5
times the Maximum Take-Off Mass (MTOM) of the heaviest helicopter intended to use
the landing area. This may only be reduced, subject to agreement from both the Classification
Society and Administration.
-
24.2.4 The officer(s) in charge of each helicopter landing area operations team should be
in possession of an Offshore Petroleum Industry Training Organisation (OPITO) Approved
Offshore Helicopter Landing Officer (HLO) certificate. All other crew assigned duties
within the helicopter landing area operations team(s) should be in possession of an
OPITO Approved Offshore Emergency Helideck Team Member certificate. Certification
from an equivalent course approved by the Administration will also be accepted. All
helicopter operations certification should be in date.
-
24.2.5 All crew on board should undergo familiarisation training regarding helicopter operations
on board and it is recommended that all crew undertake helicopter crash survivability
(‘dunker’) training at a recognised OPITO training centre, prior to commencement of
duties.
-
24.2.6 Ship to shore and ship to helicopter communications procedures, ship operating procedures,
and guidance on helicopter emergencies are outlined in the ‘Large Yacht Helicopter
Operations Handbook’ and ‘Large Yacht Helicopter Refuelling Handbook’ published by
the MCA, these should be used as part of the operational procedures of the vessel,
and equipment carried should permit crew to comply with the onboard procedures.
-
24.2.7 Refuelling of the helicopter while engines and rotors are running is prohibited.
24.3 Pilot for Vessel
Boarding arrangements provided for pilots should have due regard for SOLAS Chapter
V, Regulation 23 and IMO Resolution A.889 (21) ‘Pilot transfer arrangements’, International
Maritime Pilots’ Association (IMPA) recommendations, or any documents replacing them.
Also see National Annex for any national requirements.
24.4 Gangways, Passerelles, and Accommodation Ladders
-
24.4.1 A safe means of access is to be provided at all times when in port, either deployed
or available for deployment. If the safe means of access is not deployed, there should
be a means provided for communication between those on the quay and those onboard.
-
24.4.2 When provided, gangways, passerelles, and accommodation ladders should be manufactured
to a recognised national or international standard, and be clearly marked with the
manufacturer's name, the model number, the maximum design angle of use and the maximum
safe loading (by number of persons and by total weight). Side screens or handrail(s)
should be provided on both sides.
-
24.4.3 Where gangways, passerelles or ladders do not comply with national or international
standards, a manufacturer’s test load certificate should be provided. Alternatively
practical tests may be carried out to the satisfaction of the Administration. In all
cases the maximum design angle, maximum number of persons, and the maximum total weight
should be clearly marked, and are to be used in accordance with the manufacturer’s
instructions.
-
24.4.4 Accommodation ladders should be provided on a vessel of 120 metres in length and over.
-
24.4.5 Access equipment and immediate approaches to it should be adequately illuminated.
-
24.4.6 Reference standards include:
BSMA 78:1978 – Gangways (excluding the maximum overall widths specified in table 2);
and
BSMA 89:1980 – Accommodation Ladders;
ISO 7061:1993 -Shipbuilding – Aluminium shore gangways for seagoing vessels;
ISO 5488:1979 – Shipbuilding – Accommodation ladders.
24.5 Submersible Craft
-
24.5.1 Submersible Craft carried on yachts should comply with the standards specified in
the National Annex and include the following:
-
24.5.2 They should be constructed and maintained in accordance with the rules of a recognised
Classification Society, applicable national regulations and be suitable for the intended
use.
-
24.5.3 Supporting equipment should be constructed and maintained in accordance with the rules
of a recognised Classification Society and any applicable national regulations. The
maximum safe working load of the equipment and maximum sea state in which the craft
may be launched are to be stated.
-
24.5.4 A safety management system which may be separate from any system operated by the parent
vessel, including an operations manual, must be in place, and subject to annual audit.
-
24.5.5 Following satisfactory survey and audit, certification for safety of submersible craft
and its support equipment should be issued, and is subject to annual survey.
-
24.5.6 Maintenance should be carried out by the manufacturer or an organisation or person
accepted by the Administration at intervals specified by the manufacturer.
-
24.5.7 Operating crew to have adequate theoretical and practical training for the type of
submersible craft onboard, and have demonstrated ability to operate it.
25 CLEAN SEAS
-
25.1 Vessels should comply with all the requirements of MARPOL as prescribed by the regulations
of the Administration. For vessels under 400GT it is the owner’s responsibility to
comply with local Administration/port state requirements and for dealing with oily
bilge water retention etc.
-
25.2 Every ship of 100GT and above, and every ship which is certified to carry 15 persons
or more, should carry a garbage management plan which should include the written procedures
agreed for collection, storage, processing and disposal of garbage; and a garbage
record book recording disposal and incineration, as outlined in regulation 9 of Annex
V of MARPOL.
-
25.3 Special local requirements may exist in national sea areas, ports and harbours. The
attention of owners/operators is drawn to the need to comply with local requirements
as appropriate.
-
25.4 All yachts should comply with the hull Anti-Fouling System Convention requirements,
see National Annex.
26 MANNING and PERSONNEL CERTIFICATION
26.1 HOURS OF WORK
26.1.1 Principles of Safe Manning
IMO Resolution A.890(21) adopted on the 25th November 1999 defines the principles
of Safe Manning to ensure the safe operation of, and prevention of pollution from,
ships to which the Convention applies. Convention 180 of the International Labour
Organization(ILO) (Seafarer’s hours of work and the manning of ships) came into force
on the 10th January 2003 and applies to all commercially operated vessels.
The underlying principles of safe manning are considered to extend to Large Yachts
within the context of the Code. In this respect an Administration may choose to adopt
these arrangements in full, or modify these arrangements to meet particular operational
circumstances.
All sea going commercially operated yachts and sail training vessels of more than
24 metres Load Line Length should carry an appropriate number of qualified Deck and
Engineer Officers to ensure a degree of safety at least equivalent to that established
by the IMO guidelines.
26.1.2 Application and Definitions
These guidelines apply to all ‘seafarers employed or engaged in any capacity on board every commercially operated
large yacht’.
26.1.3 Responsibility
Fatigue at sea is a serious safety issue and owners and operators should ensure that
all vessels are sufficiently manned to avoid the need to work excessive hours. The
owner/operator and the Master are responsible for ensuring, so far as is reasonably
practicable, that the Master and all the crew members are properly rested when they
begin work and can obtain adequate rest when not on duty.
The owner/operator should ensure that the necessary resources are available to man
the vessel so that the limits on hours can be observed. The master is responsible
for ensuring compliance with the requirements.
It is also the responsibility of all seafarers to ensure that they are properly rested
when they begin duty on the vessel and that they obtain adequate rest when not on
duty.
26.1.4 Definition of Hours of Work
Hours of work is defined as when a seafarer is at their employers’ disposal and carrying
out their duties or activities.
26.1.5 On-Call Time
Where a seafarer’s normal period of rest on board a vessel is disturbed by a callout
he/she should have adequate compensatory rest.
26.1.6 Minimum Hours of Rest
The owner/operator or Master should ensure that the crew are provided with at least
the minimum hours of rest. These should not be less than:
Hours of rest may be divided into no more than 2 periods; one of which should be at
least 6 hours long, and the interval in between should not exceed 14 hours.
It is expected that as far as practicable the Master will arrange for conducting emergency
drills such as musters, fire-fighting and abandon vessel drills in a way which minimises
the disturbance to rest periods and provide compensatory rest for seafarers whose
normal rest is disturbed by call-outs for drills.
26.1.7 Exceptions to the Limits on Hours of Rest
The limits defined should as far as practicable be observed. However, an exception
maybe considered so long as they are agreed between the Master, crew members and designated
person ashore (if applicable), and provided that their health and safety, and the
safety of the vessel, is not compromised. Exceptions from the weekly rest period provided
for in paragraph 26.1.6 should not be allowed for more than two consecutive weeks.
The intervals between two periods of exceptions on board should not be less than twice
the duration of the exception.
When considering whether an exception is appropriate, the Master should give due regard
to the associated duties being considered and in this respect exceptions to persons
undertaking watch keeping duties and/or with safety critical duties would not be considered
appropriate.
In allowing any such agreed exception and to ensure that a crew member does not become
fatigued, such exceptions should be documented and accompanied by commensurate rest
arrangements.
26.1.8 Schedule of Duties
The Master should ensure that a schedule of duties is drawn up setting out the hours
of work and rest periods for each of the crew. It is recommended that the table or
schedule should be in a similar format to that detailed in Annex A of MSN 1767, and
show:
In devising the schedule, operators should take account of factors such as:
-
a) nature of the operation;
-
b) type and size of vessel;
-
c) construction and technical equipment of the vessel;
-
d) manning levels and changes in crew numbers due to crew changes and sickness;
-
e) the maximum period of continuous watchkeeping;
-
f) minimum rest periods;
-
g) total workload;
-
h) compliance with the ISPS Code as applicable;
-
i) the seriousness of irregular working hours and their contribution to causing fatigue
and the importance of scheduling reasonably stable working hours.
Changes should not be made to the schedule of duties unless they can be justified
by substantially altered work patterns or other significant factors.
Where it is known that a vessel engages in an irregular pattern or that working hours
are unlikely to be uniform, this can be taken into account when considering the schedule.
It is not necessary to draw up a new schedule of duties for each voyage, so long as
it is applicable to the voyage in question and the composition of the crew for whom
it was originally intended has not changed.
A copy of the schedule should be made available to all members of the crew.
26.1.9 Exceptions for Emergencies
Situations may arise in which a seafarer may be required to work during scheduled
hours of rest. These include emergencies which threaten the safety of the vessel or
put life at risk. In these circumstances, the limits may be exceeded provided compensatory
arrangements are subsequently made to avoid fatigue.
26.1.10 Records
The master or authorised person is responsible for ensuring that records of hours
of rest are maintained for each of the crew serving on the vessel. The records should
be completed monthly in arrears. Each record should be endorsed by the master or authorised
person and the seafarer. A copy should be retained by the seafarer.
In an emergency, or when unforeseen events occur, changes may be unavoidable. In these
cases records should reflect all deviations from the schedule.
All records should be kept for a minimum of 12 months and should be available for
inspection by the flag Administration surveyors at any time. Checking the vessel’s
records may be carried out by the flag Administration as part of the normal routine
of vessel inspection and will include a check that the appropriate schedules are available
and records maintained.
26.2 SAFE MANNING
26.2.1 Introduction
An Administration should ensure that all vessels are safely and sufficiently manned
in relation to the nature of their operation with the responsibilities placed on companies
owning or operating seagoing vessels, to ensure that their vessels are manned with
personnel of appropriate grades who have been properly trained and certificated.
The numbers of certificated officers and certificated and non-certificated ratings,
must be sufficient to ensure safe and efficient operation of the vessel at all times.
The guidelines place a duty on the owner or operator to provide the master of a vessel
with the necessary resources to comply with the manning requirements.
26.2.2 Responsibilities of Owners and Operators: General Principles
In fulfilling their responsibility to ensure that vessels are safely and sufficiently
manned, owners and operators should:
-
.1 make an assessment of the tasks, duties and responsibilities of the vessel’s complement
required for its safe operation, for the protection of the marine environment and
dealing with emergency situations;
-
.2 assess the numbers and grades/capacities in the vessel’s complement required for the
safe operation and for the protection of the environment, and for dealing with emergency
situations, including the evacuation of passengers where applicable;
-
.3 ensure that the manning level is adequate at all times and in all respects, including
meeting peak workloads;
-
.4 in case of changes in the nature of the operation, operational area, construction,
machinery, equipment or maintenance of the vessel, which may affect the manning level,
review the manning level.
In conjunction with these factors the owner or operator should:
-
.5 dentify all the functions to be undertaken on board during a representative voyage
or operational period, including determination of the number of crew required to undertake
the relevant tasks and duties under both peak and routine work load conditions. Due
consideration should also be given to the number of hotel staff required;
-
.6 identify those functions that constitute a normal operation and determine the numbers
of crew required to undertake the concurrent tasks and duties safely;
-
.7 identify the skills and experience required to perform those functions;
-
.8 establish working arrangements to ensure that the master and crew are capable of undertaking
concurrent and continuing operations at the appropriate level(s)of responsibility,
as specified, with respect to their skills and training; and
-
.9 ensure that the working arrangements allow for sufficient rest periods to avoid fatigue.
26.2.3 Establishing Safe Manning Requirements
Specific factors to be taken into account in determining the safe manning level may
include:
-
.1 frequency of port calls, length and nature of the voyage;
-
.2 operating area(s), waters and type of operations in which the vessel is involved and
any special requirements of the operation;
-
.3 number, size (kW) and type of main propulsion units and auxiliaries;
-
.4 size, type of vessel, equipment and layout;
-
.5 construction and technical equipment of vessel;
-
.6 method of maintenance;
-
.7 how the proposed complement will deal with various emergency situations that may arise;
-
.8 navigational duties and responsibilities as required by STCW 95 including the following
to:
-
.1 plan and conduct safe navigation;
-
.2 maintain a safe navigational watch;
-
.3 manoeuvre and handle the vessel in all conditions and during all operations;
-
.4 safely moor and unmoor the vessel; and.
-
.5 maintain safety whilst in port.
-
.9 Vessel specific operations:
-
.10 Vessel operations and care for persons onboard, and maintaining life- saving, fire-fighting
and other safety systems in operational condition.
-
.1 maintain the safety and security of all persons on board and keep life saving, fire
fighting and other safety systems in operational condition, including the ability
to muster and disembark passengers and nonessential personnel;
-
.2 operate and maintain watertight closing arrangements;
-
.3 perform operations necessary to protect the marine environment;
-
.4 provide medical care on board;
-
.5 undertake administrative tasks required for the safe operation of the vessel; and
-
.6 participation in mandatory safety drills and exercises.
-
.11 Marine engineering tasks and duties:
-
.1 operate and monitor the vessel’s main propulsion and auxiliary machinery;
-
.2 maintain a safe engineering watch;
-
.3 manage and perform fuel and ballast operations; and
-
.4 maintain vessel’s engine equipment, system and services.
-
.12 Electrical, electronic and control engineering duties:
-
.13 Radio communications:
-
.1 transmit and receive information using vessel communication equipment;
-
.2 maintain a safe radio watch;
-
.3 provide communications in emergencies.
-
.14 Maintenance and repair:
-
.15 Fulfil obligations and requirements of the ISPS Code as applicable.
26.2.4 Guidance on Appropriate Manning Levels
In determining what constitutes a minimum safe manning level, useful guidance may
also be obtained by use of risk and hazard management tools such as formal safety
assessment. The minimum safe manning levels should be those required for all reasonably
foreseeable circumstances and working conditions to permit the safe operation of the
vessel under normal operational conditions. Due consideration should also be given
to the number of hotel staff required.
26.2.5 Safe Manning Document
SOLAS requires that vessels over 500GT, excluding pleasure yachts not engaged in trade,
carry a Safe Manning Document. Owners and operators of vessels below 500GT, or those
above 500GT solely engaged for pleasure, may also choose to hold a Safe Manning Document.
This will allow the owner to consider a ‘range and risk’ approach when determining
manning levels.
26.2.6 Application for a Safe Manning Document
Any application for a Safe Manning Document should be made by the owner, or a person
authorised to act on their behalf, to the flag Administration of the vessel and include
a clear and concise explanation of how:
-
.1 the proposed manning level has been determined;
-
.2 it takes account of the guidance; and
-
.3 it takes account of the hours of work provisions.
A proposal should only be approved and Safe Manning Document issued provided the manning
level fully satisfies these principles, recommendations and guidelines.
When the manning level has been agreed, a Safe Manning Document should be issued for
that vessel in a format which complies with the requirements of SOLAS, as amended.
It should be retained on board and be available for inspection by an authorised person,
whenever required.
In the event of any change in equipment, construction or use of the vessel, which
may affect the safe manning level, the owner or operator should make an application
for the issue of a new Safe Manning Document.
A Safe Manning Document of a vessel may be withdrawn if an owner or operator fails
to submit a new proposal where a vessel changes trading area(s), construction, machinery
or equipment, or operation and/or method of maintenance have changed, or a vessel
persistently fails to comply with the rest hours requirements.
26.2.7 Indicative Manning Levels
The owner/operators or managing agent of all seagoing yachts of more than 24 metres
Load Line length must ensure that personnel required for the safe operation of the
vessel have recent and relevant experience of the type and size of vessel, and the
type of operation in which it is engaged. See National Annex.
26.2.8 Sailing Vessels
Depending on the type of rig and level of automation, additional personnel may be
required to operate the rig of a sailing vessel.
26.2.9 Personal Water Craft
The operators are reminded that operation of personal watercraft should comply with
the applicable legislation of the state in whose waters they are being operated.
27 PASSENGERS
No vessel to which the Code applies should carry more than 12 passengers on a voyage
or excursion. The following meanings apply:
‘Passenger’ means any person carried in a ship except:
-
(a) a person employed or engaged in any capacity on board the ship on the business of
the ship;
-
(b) a person on board the ship either in pursuance of the obligation laid upon the master
to carry shipwrecked, distressed or other persons, or by reason of any circumstances
that neither the master nor the owner nor the charterer (if any) could have prevented;
and
-
(c) a child under one year of age; and
‘a person employed or engaged in any capacity on board the vessel on the business
of the vessel’ may reasonably include:
-
.1 bona-fide members of the crew over the minimum school leaving age (about 16 years)
who are properly employed on the operation of the vessel;
-
.2 person(s) employed either by the owner or the charterer in connection with business
interests and providing a service available to all passengers; and
-
.3 person(s) employed either by the owner or the charterer in relation to social activities
on board and providing a service available to all passengers.
With reference to .2 and .3 above, such persons should be included in the crew list
required for the vessel, should have received on board familiarisation training as
required by STCW, and should not be assigned duties on the muster list.
28 SURVEY, CERTIFICATION, INSPECTION AND MAINTENANCE
28.1 General
-
28.1.1 All vessels covered by this code are required to be surveyed and certificated in accordance
with the International Load Line Convention; vessels over 400GT under the MARPOL Convention.
Vessels over 500GT are required to be surveyed and certificated under the construction
and safety equipment requirements of the SOLAS Convention. All vessels of over 300GT
are also required to be surveyed and certificated under the radio requirements of
SOLAS. Annex 4 is the list of certificates to be issued.
-
28.1.2 Statutory work may be undertaken by surveyors of the Administration or by surveyors
of a Classification Society appointed by the Administration and, for safety radio,
an appropriate Certifying Authority in relation to radio installations. See National
Annex for delegations.
-
28.1.3 A vessel to which the International Conventions apply must be surveyed and, if the
necessary standards are met, Convention certificates will be issued. All requests
for survey and certification must be made to the Administration, the appropriate Classification
Society or appropriate Certifying Authority in relation to radio installations. See
National Annex for delegations.
28.2 Initial Survey (including new-building commercial vessels)
Vessels are required to be issued with the following certificates, as appropriate.
-
.1 International Load Line Certificate (all vessels).
-
.2 Certificate of Compliance (all vessels) – this certificate is to cover all aspects
of the Code for which a separate certificate is not required.
-
.3 Cargo Ship Safety Construction Certificate (vessels of 500GT and over).
-
.4 Cargo Ship Safety Equipment Certificate (vessels of 500GT and over).
-
.5 Cargo Ship Safety Radio Certificate (vessels of 300GT and over).
-
.6 International Oil Pollution Prevention Certificate (vessels of 400GT and over).
-
.7 International Tonnage Certificate (all vessels).
-
.8 Safe Manning Document (vessels of 500GT and over).
-
.9 Safety Management Certificate (SMC) (vessels of 500GT and over).
-
.10 International Ship Security Certificate (ISSC) (vessels of 500GT and over).
-
.11 International Sewage Pollution Prevention Certificate (vessels of 400GT and over,
or carrying more than 15 persons).
-
.12 International Air Pollution Prevention Certificate (vessels of 400GT and over). Vessels
under 400 GT each engine having power output greater than 130kW Engine International
Air Pollution Prevention Certificate.
-
.13 Antifouling System Certificate of Compliance (vessels of 400GT and over) (vessels
less than 400GT require a declaration on AFS).
-
.14 Maritime Labour Certificate and Declaration of Maritime Labour Compliance (Vessels
over 500 GT, Declaration recommended for vessels under 500 GT)
28.3 Equivalents to certain safety regulations
If an owner/managing agent seeks any equivalence to the application of specific regulations
or requirements, formal application must be made to the Administration, demonstrating
an equivalent level of safety. The Administration may consider and agree the application.
28.4 Periodical Surveys
-
28.4.1 Load Line Certificates, Cargo Ship Safety Construction Certificates and Certificates
of Compliance (valid for 5 years in general).
Annual, intermediate and renewal surveys with respect to the Load Line Certificates,
the Cargo Ship Safety Construction Certificates and the Certificate of Compliance
should be carried out to the satisfaction of the Administration or Class Society as
appropriate.
Any certificate is to be valid for not more the 5 years from the date of survey.
28.4.2 Cargo Ship Safety Equipment and Safety Radio Certificates
-
24.4.2.1 Safety Equipment Certificates and Safety Radio Certificate surveys should be carried
out either by the Administration or Parties to the SOLAS Convention at the request
of a the Administration; or by a Classification Society surveyor appointed by the
Administration to act on its behalf; or by an appropriate Certifying Authority in
relation to radio installations for cargo ships.
-
24.4.2.2 An application to the Administration for an extension to the certificate will be agreed
only in cases when it appears proper and reasonable to do so.
-
24.4.2.3 At least once during a five year period, a surveyor appointed by the Administration
will visit the ship to survey its safety equipment and to conduct a general inspection
to ensure that standards are being met.
28.5 Use of an Authorised Classification Society
An authorised Classification Society is aware of the extent to which responsibility
has been delegated to issue Load Line Certificates and Cargo Ship Safety Construction
Certificates. International Conventions give specific discretion to an Administration
to either make exemptions or accept equivalent equipment or arrangements. The formal
agreement between the Administration and an authorised Classification Society governs
the relationship between the two parties.
28.6 Use of a Classification Society Surveyor to act on the behalf of the Administration
An exclusive surveyor from an authorised Classification Society and proposed by the
Society may be appointed from time to time to act on behalf of the Administration
in cases when it is impracticable for a surveyor of the Administration to make the
visit necessary for the survey.
When a Classification Society surveyor is so appointed, actions taken will be under
direct instruction of the Administration. The Administration will provide the appointed
surveyor with detailed guidance on the scope of survey and report required.
28.7 Accident Investigations
The Administration with which the vessel is registered is obliged to investigate accidents
or incidents in accordance with the requirements of International Conventions. Apart
from this legal requirement, an Administration investigates such occurrences to demonstrate
the effective control and importance they attach to safety at sea.
It is an offence for the vessel's master, skipper or owner not to inform the appropriate
authority of a reportable accident shortly after it occurs and to provide details
so that an assessment of its seriousness can be made quickly. The marine Administration
will appoint a suitable surveyor or inspector whenever an investigation is required.
The Marine Administration will then receive the Surveyor's or the Inspector's report
and will deal with the follow up action.
All very serious casualties in accordance with the International Maritime Organization's
(IMO) definition should be reported to IMO through the Administration.
29 CREW AGREEMENTS
29.1 Crew Agreements should be available on board as required by the Administration.
29A
Section 29 may be amended by the introduction of the International Labour Organization’s
(ILO) requirements under the Maritime Labour Convention (MLC) 2006.
30 SAFETY MANAGEMENT
-
30.1 All vessels of 500GT and over, and associated managers, are required to comply with
the IMO’s International Safety Management Code.
-
30.2 All vessels under 500GT should employ a safety management system as described in Annex
2.
-
30.3 All vessels should include emergency towing procedures, as required by SOLAS regulation
II-1/3-4, in their safety management system or in a separate plan.
31 INTERNATIONAL SHIP AND PORT FACILITY CODE
All vessels of 500GT and over are required to comply with the IMO’s International
Ship and Port Facility Security Code.
ANNEX 1 MEMBER’S OF THE STEERING COMMITTEE AND WORKING GROUP RESPONSIBLE FOR THE CODE
Steering Committee
British Marine Federation Cayman Islands Shipping Registry Maritime and Coastguard
Agency
Professional Yachtsmen's Association Royal Yachting Association
Working Group
Ince & Co LLP
Hill Dickinson LLP
Isle Of Man Shipping Registry
BMT Nigel Gee Ltd
Sunseeker International Ltd
Burgess Yachts
Oyster Marine Ltd
British Marine Federation
UCINA – Italian Marine Industry Association
SYBAss
Azimut / Benetti S.p.A.
Fr. Lurssen Werft GmbH & Co. KG
Feadship Holland
Perini Navi Spa
MYBA
Burness Corlett Three Quays (Southampton) Ltd
ABS
RINA UK Ltd
Lloyds Register
Nippon Kaiji Kyokai
ANNEX 2 SAFETY MANAGEMENT SYSTEM FOR VESSELS UNDER 500GT
INTRODUCTION
GENERAL
-
2. Each operator should create a safe working environment, which should include the following:
A health and safety protection policy.
-
2.1 This must address the issues of health, safety and the environment as they affect
the company and its staff, both ashore and afloat. Such a policy might read along
the following lines:
‘The policy of (name of Company/Owner) is to conduct its activities taking full account
of the health and safety of its employees and of all persons using or connected with
the Company/Owner. In implementing this policy, (name of Company/Owner) will ensure
that the [vessel] is, at all times, properly maintained and operated by qualified
personnel in full compliance with relevant legislation. In particular the [Company/Owner]
will carry out an assessment of the risks to the health and safety of workers and
others affected by [the undertaking], and will take the necessary measures to minimise
the risks identified.’
-
2.2 The owner/operator is recommended to develop and implement an oil management plan
to the same standard as the garbage management plan and to integrate it with the Health
and Safety Protection Policy. This is not required for vessels over 400GT, for which
an IOPP certificate is required.
Procedures to ensure safe operation of vessels in compliance with the regulations
and rules.
-
2.3 The regulations and rules, not addressed by this Code of Practice, which apply to
all vessels include, but are not limited to:
-
• International Regulations for Preventing Collisions at Sea;
-
• Local Navigation Rules;
-
• National health and safety regulations;
-
• The Code of Safe Working Practices for Merchant Seamen;
-
• All relevant national shipping or guidance notices.
-
2.3.1 The company should draw up simple procedures to ensure that safe working practices
are carried out in the operation of the vessel. These may be in the form of checklists
which can be followed by all personnel.
-
2.3.2 For some vessels, it might be appropriate to have permanently exhibited checklists,
e.g. in the wheelhouse for navigational items. Alternatively, in a smaller vessel,
the record could take any suitable form such as a diary as distinct from a specially
printed logbook. Whatever form the record takes, such entries should be accepted as
evidence of compliance with the ONBOARD PROCEDURES requirements.
Lines of communication between personnel, ashore and afloat.
-
2.4 Responsibility and authority of each employee should be clear. This may be best illustrated
in a simple diagram, showing who reports to whom.
Procedures for reporting accidents.
-
2.5 The requirement for reporting accidents should be well understood by all personnel
and in so doing improve the safety culture practiced on board.
Procedures for responding to emergency situations.
-
2.6 There should be clearly stated procedures for responding to emergency situations.
These may include but not be limited to:
-
2.6.1 Checklists may be useful in this regard.
HEALTH AND SAFETY PROTECTION POLICY
-
3. One or more competent persons should be delegated to take responsibility for health
and safety, and that person/persons should be clearly identified. It is the responsibility
of the owner/operator to ensure that the policy is complied with, and that the responsibilities
are understood.
-
4. The company/owner should develop a policy on prevention of alcohol and drug abuse.
-
5. All personnel both ashore and afloat have a duty to take care of themselves and other
persons who may be affected by their acts or omissions.
-
6. It is essential that, in the event of an emergency, there is the ability to communicate
with the emergency services via a shore base. The shore base may be the company office
ashore, the local Coastguard, Police or Fire Station, or another office as may be
agreed between the vessel and the shore base.
RESPONSIBILITIES
-
7. The Master must have authority at all times, to make decisions with regard to the
safety of the vessel and the persons on board. To ensure that there is no ambiguity
regarding the authority of the Master, there should be a simple written statement
to this effect.
PERSONNEL AND TRAINING
-
8. All personnel should receive training appropriate to the tasks they undertake. It
is the responsibility of the company/owner to ensure that this training is given,
and that the personnel have an understanding of the relevant regulations and rules.
-
9. As a minimum, this means:
-
• for the Master, the relevant qualifications;
-
• for the crew, relevant qualifications and any additional training appropriate to their
designated duties.
-
10. Prior to the first occasion of working on the vessel, each employee must receive appropriate
familiarisation training and proper instruction in onboard procedures. This could
include, but not necessarily be, limited to:
-
• mooring and unmooring;
-
• launching and recovery of survival craft;
-
• evacuation from all areas of the vessel;
-
• donning of lifejackets; and
-
• use and handling of fire fighting equipment.
ONBOARD PROCEDURES
PREPARATION FOR EMERGENCIES
-
12. The potential emergencies likely to be encountered by the vessel should be considered.
Exercises should then be carried out in the handling of these emergencies and evacuation
from the vessel.
-
13. Where possible, all personnel should be involved in these exercises, both ashore and
afloat.
-
14. The roles and responsibilities of all personnel in an emergency situation should be
defined.
-
15. The exercises should be recorded. The names of those who participated should also
be recorded.
REPORTING OF ACCIDENTS
-
16. Vessels operating under this Code are required to report any accidents to the Administration
and the company must therefore have a procedure in place. Additionally, all accidents
and near accidents should be recorded and reported to the operator/owner, who should
implement corrective action, with the aim of improving safety.
MAINTENANCE OF THE VESSEL AND EQUIPMENT
-
17. Maintenance of the vessel and equipment is an essential ingredient of safety management.
The equipment should be checked and tested daily when in use, in addition to the tests
referred to in the ONBOARD PROCEDURES section of the Code.
-
18. There should be procedures for a more detailed inspection and maintenance programme
of the vessel and equipment.
-
19. The frequency of the inspections should be determined by the owner/operator, but every
event should be recorded.
-
20 A checklist could be employed as an aide memoir for the inspection of equipment.
REVIEW
ANNEX 3 OPEN FLAME GAS INSTALLATIONS
1 General Information
-
1.1 Possible dangers arising from the use of liquid petroleum gas (LPG) open flame appliances
in the marine environment include fire, explosion and asphyxiation, due to leakage
of gas from the installation.
-
1.2 Consequently, the siting of gas-consuming appliances and storage containers and the
provision of adequate ventilation to spaces containing them, is most important.
-
1.3 It is dangerous to sleep in spaces where gas-consuming open flame appliances are left
burning, because of the risk of carbon monoxide poisoning.
-
1.4 LPG is heavier than air and if released, may travel some distance whilst seeking the
lowest part of a space. Therefore, it is possible for gas to accumulate in relatively
inaccessible areas, such as bilges, and diffuse to form an explosive mixture with
air, as in the case of petrol vapour.
-
1.5 A frequent cause of accidents involving LPG installations is the use of unsuitable
fittings and improvised ‘temporary’ repairs.
2 Stowage of Gas Containers
-
2.1 LPG cylinders, regulators and safety devices should be stowed on the open deck (where
leakage will not accumulate) or in a compartment that is vapour-tight to the vessels
interior, and fitted with a vent and drain, so that any gas which may leak can disperse
overboard.
-
2.2 The vent and drain should not be less 19mm in diameter, run to the outside of the
craft and terminate 75mm or more above the ‘at rest’ waterline. Generally, the drain
and locker ventilation should be 500 mm or more from any opening to the interior.
-
2.3 The cylinders and associated fittings should be positively secured against movement
and protected from damage in any foreseeable event.
-
2.4 Any electrical equipment located in cylinder lockers should be certified safe for
use in the potential explosive atmosphere.
3 Cylinders and Attachments
-
3.1 Each system should be fitted with a readily accessible, manually operated isolating
valve in the supply pressure part of the system.
-
3.2 In multiple container installations, a non-return valve should be placed in the supply
line near to the stop valve on each container. If a change-over device is used (automatic
or manual), it should be provided with non-return valves to isolate any depleted container.
-
3.3 Where more than one container can supply a system, the system should not be used with
a container removed, unless the unattached pipe is fitted with a suitable gas tight
plug arrangement.
-
3.4 Containers not in use or not being fitted into an installation should have the protecting
cap in place over the container valve.
4 Fittings and Pipework
-
4.1 For rigid pipework systems solid drawn copper alloy or stainless steel tube should
be used. Steel tubing, aluminium, or any materials having a low melting point should
not be used.
-
4.2 Connection between rigid pipe sections should be made with, hard solder (minimum melting
point 450°C). Appropriate compression or screwed fittings are recommended for general
use for pipework in LPG installations.
-
4.3 Lengths of flexible piping (if required for flexible connections) should conform to
an appropriate standard, be kept as short as possible, and be protected from inadvertent
damage. Such hose should be installed in such a manner to allow access for inspection
along its length.
Proposals for a more extensive use of flexible piping (which conforms to an internationally
recognised standard for its application) should be submitted to the Administration
for approval on an individual basis.
5 Appliances
-
5.1 All appliances should be well secured to avoid movement.
-
5.2 All unattended appliances should be of the room sealed type, i.e where the gas flames
are isolated in a totally enclosed shield where the air supply and combustion gas
outlets are piped to open air.
-
5.3 All gas burners and pilot flames should be fitted with a flame supervision device
which will shut off the gas supply to the burner or pilot flame in the event of flame
failure.
-
5.4 Flue-less heaters should be selected only if fitted with atmosphere-sensitive cut-
off devices to shut off the gas supply at a carbon dioxide concentration of not more
than 1.5% by volume.
-
5.5 Heaters of a catalytic type should not be used.
6 Ventilation
-
6.1 The ventilation requirements of a space containing a LPG appliance should be assessed
against an appropriate standard and should take into account gas burning equipment
and persons occupying that space.
-
6.2 Where ventilators required for LPG appliances in intermittent use can be closed, there
should be appropriate signs at the appliance warning of the need to have those ventilators
open before the appliance is used.
7 Gas Detection
-
7.1 Suitable means for detecting the leakage of gas should be provided in any compartment
containing a gas-consuming appliance, or in any adjoining space of a compartment into
which the gas (more dense than air) may seep.
-
7.2 Gas detectors heads should be securely fixed in the lower part of the compartment
in the vicinity of the gas-consuming appliance and in other space(s) into which gas
may seep.
In areas where the detector head is susceptible to damage in the lowest part of the
compartment (e.g. engine space bilge) the detector head should at least be fitted
below the lowest point of ignition.
-
7.3 Any gas detector should preferably, be of a type which will be actuated promptly and
automatically by the presence of a gas concentration in air of not greater than 0.5%
(representing approximately 25% of the lower explosive limit). The detection system
should incorporate a visible alarm and an audible alarm which can be heard in the
space concerned and the control position with the vessel in operation.
-
7.4 Where electrical detection equipment is fitted, it should be certified as being flame-proof
or intrinsically safe for the gas being used.
-
7.5 In all cases, the arrangements should be such that the detection system can be tested
frequently whilst the vessel is in service, which should include a test of the detector
head operation as well as the alarm circuit, in accordance with the manufacturer’s
instructions.
-
7.6 All detection equipment should be maintained in accordance with the manufacturer’s
requirements.
8 Emergency Action
-
8.1 A suitable notice, detailing the action to be taken when an alarm is given by the
gas detection system, should be displayed prominently in the vessel.
-
8.2 The information given should include the following:
-
.1 The need to be ever alert for gas leakage; and
-
.2 When leakage is detected or suspected, all gas-consuming appliances should be shut
off at the main supply from the container(s) and NO SMOKING should be permitted until
it is safe to do so.
-
.3 NAKED LIGHTS SHOULD NEVER BE USED AS A MEANS OF LOCATING GAS LEAKS.
ANNEX 4 LIST OF CERTIFICATES TO BE ISSUED
Certification
|
Subject & Convention
|
Limits
|
Detail & Remarks
|
International Tonnage Certificate
|
Tonnage ITC 69
|
≥ 24 metres
|
|
International Load Line Certificate
|
Load Line ILLC'66
|
≥ 24 metres
|
Intact Stability & Subdivision Standard1
|
Cargo Ship Safety Construction Certificate
|
Construction SOLAS 74
|
≥500GT
|
Construction1
|
Fire Protection SOLAS 74
|
≥500GT
|
Structural Fire Protection & Means of Escape 1
|
Cargo Ship Safety Equipment Certificate
|
Fire Appliances SOLAS 74
|
≥500GT
|
Fire Appliances1
|
Life Saving Appliances SOLAS 74
|
≥500GT
|
Life – Saving Appliances1
|
Navigation Equipment SOLAS 74
|
≥500GT
|
Navigation lights, sounds, signals1 etc
|
Cargo Ship Safety Radio Certificate
|
Radio SOLAS 74
|
≥300GT
|
Communications
|
Safe Manning Document
|
Manning STCW 95
|
≥500GT
|
Manning1
|
International Oil Pollution Prevention Certificate
|
Pollution MARPOL Annex I
|
≥400GT
|
Oil Pollution Prevention Equipment
|
International Sewage Pollution Prevention Certificate
|
Pollution MARPOL Annex IV
|
≥400GT
or >15 persons
|
Sewage Pollution Prevention
|
International Air Pollution Prevention Certificate/EIAPP
|
Pollution MARPOL Annex VI
|
≥400GT
or
>130kw
|
Air Pollution Prevention
|
Anti-Fouling System Certificate of Compliance
|
|
≥400GT
|
Hull Anti-Fouling
Declaration required for <400 GT
|
Safety Management Certificate
|
International Safety Management Code
|
≥500GT
|
Operations1
|
International Ship Security Certificate
|
International Ship and Port Facility Security Code
|
≥500GT
|
Security1
|
Maritime Labour Certificate
|
Maritime Labour Convention 2006
|
≥500GT
|
Seafarer Living & Working Conditions.
(Recommended for <500GT)1
|
Certificate of Compliance
|
Various
|
≥24 metres
|
Covers aspects surveyed under the code for which other certificates are not required.1
|
X Noot
1The Administration retains the right to survey and issue certificates for this item
ANNEX 5 UNITED KINGDOM NATIONAL ANNEX
The annex contains requirements and supplementary notes specific to United Kingdom
vessels. These are referenced under the same section numbers as they would appear
in the main Code text.
2 Definitions
‘Aviation Inspection Body’ for United Kingdom see Ensign website for a current list
of current approved bodies.
‘Merchant Shipping Notice’, ‘Marine Guidance Notes’ and Marine Information Notes means
Notices/Notes described as such and issued by the Maritime and Coastguard Agency;
and any reference to a particular Notice/Note includes a reference to any document
amending or replacing that Notice/Note which is considered by the Secretary of State
to be relevant from time to time and is specified in a Merchant Shipping Notice/Note;
‘Minimum Age of Trainees’
A trainee may only sail on a vessel in which it can reasonably be expected that he
or she is physically and mentally capable of safely taking part in the operation of
the vessel. There should be specific documented provisions in place to cover the health,
safety, and welfare of the trainees. Safety management tools, such as formal safety
assessment (FSA) techniques, may be useful when considering the acceptable age of
a trainee for a specific vessel, voyage or operating area/condition. Due consideration
must also be given to the profile and balance of the crew for each voyage taking into
account the age and sex of the trainees. In any event a trainee should not be less
than 12 years of age and any person below this age must be considered as a passenger.
‘pleasure vessel’ has the same meaning as in The Merchant Shipping (Vessels in Commercial
Use for Sport or Pleasure) Regulations 1998 SI 1998/2771, as amended, as follows:
‘pleasure vessel’ means
-
(a) any vessel which at the time it is being used is:
-
(i) (aa) in the case of a vessel wholly owned by an individual or individuals, used only
for the sport or pleasure of the owner or the immediate family or friends of the owner;
or
(bb) in the case of a vessel owned by a body corporate, used only for sport or pleasure
and on which the persons on board are employees or officers of the body corporate,
or their immediate family or friends; and
-
(ii) on a voyage or excursion which is one for which the owner does not receive money for
or in connection with operating the vessel or carrying any person, other than as a
contribution to the direct expenses of the operation of the vessel incurred during
the voyage or excursion; or
-
(b) any vessel wholly owned by or on behalf of a members' club formed for the purpose
of sport or pleasure which, at the time it is being used, is used only for the sport
or pleasure of members of that club or their immediate family, and for the use of
which any charges levied are paid into club funds and applied for the general use
of the club; and
-
(c) in the case of any vessel referred to in paragraphs (a) or (b) above no other payments
are made by or on behalf of users of the vessel, other than by the owner.
In this definition ‘immediate family’ means -
in relation to an individual, the spouse or civil partner of the individual, and a
relative of the individual or the individual's spouse or civil partner; and ‘relative’
means brother, sister, ancestor or lineal descendant;
‘Seafarer’ means any person, including the master, who is employed or engaged or works
in any capacity on board a ship on the business of the ship but does not include a
person who -
‘To Sea’ means beyond Category D Waters, or Category C waters if there are no Category
D waters.
3 Application and Interpretation
-
3.1.1 This revision of the Code comes into effect on and replaces ‘The Code of Practice
for the Safety of Large Commercial Sailing and Motor Vessels’ LY2 Edition 2. Vessels
certificated to the requirements of the original Code may continue to operate under
the same provisions applicable at the time of certification. Vessels undergoing refit
or modification are encouraged to comply with the provisions of this revision as far
as is reasonable and practicable.
-
3.1.1.1 A coded vessel chartered or operated commercially, for the purpose of racing need
not comply with the provisions of the Code whilst racing, or whilst in passage directly
to or from a race, provided that the vessel complies with the following:-
-
.1 It complies with the racing rule provisions of either the International Sailing Federation
(ISAF) or the Union Internationale Motonautique (UIM).
-
.2 It complies with the racing rule provisions of the affiliated Member National Authority,
of either the ISAF or UIM, in the country where the race takes place.
-
.3 It complies with the safety rule provisions of the race Organising Authority affiliated
to the Member National Authority and thereby recognised by the ISAF or UIM to organize
races in the country where the race takes place.
-
.4 If it is a yacht racing offshore, it complies with the appropriate parts of the ISAF
Offshore Racing Committee’s special regulations or the similar requirements of the
affiliated race Organising Authority.
-
.5 When on charter and in passage to and from the race, the race or equivalent safety
cover should be in force, or the vessel is to be in its coded condition for the passage.
The relief from compliance with the provisions of the Code which is permitted by Section
3.1.1.1 does not apply to a vessel taking part in an event created and organised with
the intent to avoid the provisions of the Code.
Notes:
-
1. Only clubs recognised by an ISAF Member National Authority (MNA) may use the ISAF
racing rules. In the UK this means a club affiliated as a club to the RYA. (This does
not include RYA recognised teaching establishments).
-
2. The UIM racing rules require all racing drivers to have been licensed by a UIM MNA.
In the UK, the RYA issues such licences, which require pre medical examinations and
minimum levels of past experience.
-
3. All legitimate races are required, by the ISAF or UIM rules, to have been ‘pre-advertised’
by means of a Notice of Race and be controlled by Sailing or Race Instructions. The
minimum provisions for these are set out in the ISAF and UIM racing rules.
Construction and Strength
4.3.1 Classification Societies
American Bureau of Shipping
Bureau Veritas
Det Norske Veritas
Germanisher Lloyd
Lloyds Register
Nippon Kaiji Kyokai
Registro Italiano Navale
14.A Structural Fire Protection – Vessels of Less Than 500GT
14A.2.3.8 14B.2.11 See MGN 453 – FIRE PROTECTION – Fire Retardant Treatment Treatment for Floor Coverings,
Suspended Textile Materials, Upholstery Materials and Bedding Components for use Onboard
Vessels Certified Under the MCA Large Commercial Yacht Code.
22 Protection of Personnel
22.5 Noise
MSN 1763 ‘The Merchant Shipping and Fishing Vessels (Safety Signs and Signals) Regulations
2001’ provides details of required safety signs.
23 Medical Stores
Medical stores requirements are contained within MSN 1768 ‘Ship’s Medical Stores’.
24.5 Submersible craft
Registration, construction and operation of submarines are regulated by the following
United Kingdom Statutory Instruments:
SI No.940 The Merchant Shipping (Registration of Submersible Craft) Regulations 1976,
as amended.
SI No.1098 The Merchant Shipping (Submersible Craft Construction and Survey) Regulations
1981.
SI No.311 The Merchant Shipping (Submersible Craft Operations) Regulations 1987.
25 Clean Seas
The IMO MARPOL Convention Annexes relevant to the operation of Large Yachts are implemented
by the following United Kingdom Statutory Instruments;
SI 1996 No. 2154 ‘Merchant Shipping (Prevention of Oil Pollution) Regulations’ as
amended.
SI 2008 No. 3257 ‘Merchant Shipping (Prevention of Pollution by Sewage and Garbage)
Regulations’, guidance on which is contained in MSN 1807 and MGN 385.
SI 2003 No. 1809 ‘Merchant Shipping and Fishing Vessels (Port Waste Reception Facilities)
Regulations’. Information on these requirements can be found in MGN 387.
SI 2008 No. 2924 ‘Merchant Shipping (Prevention of Air Pollution from Ships) Regulations
2008’. Information on these requirements can be found in MSN 1819, MGN 381, MGN
386, and MGN 400.
25.4 All yachts should comply with the hull Anti-Fouling System Convention requirements,
details of which can be found in MGN 398 and MIN 394.
26.2.4 Guidance on Appropriate Manning Levels
In addition to unrestricted STCW qualifications, information as to specific qualifications
for Large Yachts and Sail Training Vessels are contained within:
MGN 156 ‘Training and Certification Guidance – Part 17 Certificates of Competency
or Marine Engine Operator Licences for Service as an Engineer Officer on Commercially
and Privately Operated Yachts and Sail Training Vessels’, and;
MSN 1802 ‘Training and Certification Guidance – Part 21 Deck Officer Certificates
of Competency For Service on Commercially and Privately Operated Yachts and Sail Training
Vessels’.
Vessels over 3000 GT should comply with MSN 1767. Hours of Work, Safe Manning and
Watchkeeping revised Provisions from 7 September 2002
’A training organisation wishing to operate UK registered Training Vessel(s) carrying more than 12 trainees must register this intention with the Maritime and Coastguard Agency (MCA) including
details of:
-
1 The organisation together with points of contact;
-
2 Name, port of registry, size and type of vessel.;
-
3 Details of the regular crew. This may evidenced by a safe manning document. However,
in the absence of a safe manning document this should be in the form of a declaration
of the minimum manning required for contracted crew as detailed in MSN 1767 (or as
subsequently amended);
-
4 Maximum number of trainees that can be carried;
-
5 The age profile of the trainees; and
-
6 Any special circumstances relevant to the proposed operation.
If operating under a Code then the vessel’s Code Certificate of Compliance should
be endorsed 'Sail Training Vessel' or ‘Motor Training Vessel’.
Every vessel should have a Risk Assessment and Safety Policy in place. If trainees
under the age of 18 are to be carried they should also have a Child Protection policy
and appropriate code of conduct to ensure the welfare and well being of the trainees.
The registration will only be approved provided the proposal fully satisfies the recommendations
and guidelines outlined above. The MCA may require an owner or operator to amend a
proposal if, after evaluation, the proposal is considered inadequate.
A training vessel may carry a combination of passengers and trainees. However, a training
vessel operating under a Code of Practice may only carry a maximum of 12 passengers
at any time.
28.1.2 Survey, Certification, Inspection, and Maintenance
The list of UK Certifying Authorities for radio installations is listed in MGN 392.
For classed vessels, radio survey is delegated to classification societies.
28.7 Accident Investigation Reporting Regulations
Under ‘The Merchant Shipping (Accident Reporting and Investigation) Regulations’ 2005,
SI No. 881, it is a requirement to report accidents and hazardous events to the Department
for Transport’s Marine Accident Investigation Branch. Guidance is available in MGN
289 ‘Accident Reporting and Investigation’.
29 Crew Agreements
Crew Agreements should be as detailed in MGN 149 or replacement notice.
Certification
|
Subject & Convention
|
Limits
|
Detail & Remarks
|
UK Regulation
|
Delegation
|
International Tonnage Certificate
|
Tonnage ITC 69
|
≥ 24 metres
|
|
Merchant Shipping (Tonnage) Regulations 1997 SI No. 1510, as amended
|
Classification Societies
|
International Load Line Certificate
|
Load Line ILLC'66 General
|
|
Intact Stability
&Subdivision Standard;
# – Using equivalent standards of the Code
|
Merchant Shipping (Load Line) Regulations 1998 SI No. 2241, as amended
|
Assigning Authorities1
|
Inclining Test, Stability
|
≥ 24 metres
|
|
MCA
|
Cargo Safety Construction Certificate
|
Construction SOLAS 74
|
≥ 500GT
|
Construction
|
Merchant Shipping (Cargo Shipping Construction) Regulations 1997, SI No. 1509, as
amended
|
Certifying Authorities1
|
Fire Protection SOLAS 74
|
≥ 500GT
|
Structural Fire Protection & Means of Escape – Using the equivalent standards of the
Code
|
Ships constructed before 1 July 2002: Merchant Shipping (Fire Protection-Large Ships)
1998 Regulations SI No. 1012, as amended. Ships constructed on or after 1 July 2002.
Merchant Shipping (Fire Protection) Regulations 2003, SI No. 2950, as amended.
|
Certification issued by Certifying Authorities1 on a partial declaration by MCA on Structural Fire Protection, Means of Escape, Fire
Safety of Unattended Machinery Spaces and Accommodation etc
|
Cargo Safety Equipment Certificate
|
Fire Appliances SOLAS 74
|
≥ 500GT
|
Fire Appliances
|
|
MCA
|
Life Saving Appliances SOLAS 74
|
≥ 500GT
|
Life Saving Appliances
|
Merchant Shipping (Life Saving Appliances (Ships Other than Ships of Class III to
VI(A)) Regulations 1999 SI No. 2721, as amended.
|
Navigation Equipment SOLAS 74
|
≥ 500GT
|
Navigation lights, sounds, signals etc
|
Merchant Shipping (Distress Signals and Prevention of Collisions) Regulations 1996,
SI No. 75, as amended.
|
Cargo Safety Radio Certificate
|
Radio SOLAS 74
|
≥ 300GT
|
|
Merchant Shipping (Radio Installations) Regulations 1998 SI No. 2070, as amended.
|
Authorised persons.1
|
Safe Manning Document
|
Manning STCW 95
|
≥ 500GT
|
|
Merchant Shipping (Safe Manning, Hours of Work and Watchkeeping) Regulations 1997
SI No. 1320, as amended.
|
MCA
|
International Oil Pollution Prevention Certificate
|
MARPOL
Annex I
|
≥ 400GT
|
Pollution prevention equipment
|
Merchant Shipping (Prevention of Oil Pollution) Regulations 1996 SI No.
2154, as amended.
|
Classification Societies1
|
International Air Pollution Prevention Certificate
|
MARPOL
Annex VI
|
≥ 400GT
≥ 130kw
|
|
Merchant Shipping (Prevention of Air Pollution from Ships) Regulations SI 2008 No.
2924.
|
Classification Societies1
|
International Sewage Pollution Prevention Certificate
|
MARPOL
Annex IV
|
≥ 400GT
> 15
persons
|
|
Merchant Shipping (Prevention of Pollution by Sewage and Garbage) Regulations SI 2008
No. 3257.
|
Classification Societies1
|
Safety Management Certificate
|
International Safety Management Code
|
≥ 500GT
|
|
The Merchant Shipping (International Safety Management (ISM) Code) Regulations 1998
SI 1998 No. 1561 as amended.
|
MCA
|
International Ship Security Certificate
|
International Ship and Port Facility Security Code
|
≥ 500GT
|
|
The Ship and Port Facility (Security) Regulations 2004
SI 2004 No. 1495
As amended
|
MCA
|
Maritime Labour Certificate
|
Maritime Labour Convention 2006
|
≥500GT
|
Seafarer Living & Working Conditions. (Recommended for <500GT)
|
|
MCA
|
Certificate of Compliance
|
Various
|
≥24 metres
|
Covers aspects surveyed under the code for which other certificates are not required.
|
Merchant Shipping (Vessels in Commercial Use for Sport and Pleasure) Regulations 1998
SI No. 2771, as amended.
|
MCA
|
X Noot
1Classification Societies, Assigning Authorities and Certifying Authorities for Large
Yachts means one of the seven Classification Societies accepted by the Maritime &Coastguard
Agency: American Bureau of Shipping. Bureau Veritas, Det Norske Veritas, Germanischer
Lloyds, Lloyds Register of Shipping, Nippon Kaiji Kyokai and Registro Italiano Navale
ANNEX 6 TECHNICAL STANDARD FOR HELICOPTER LANDING AREAS
For environmental considerations and to minimise the size of LY3, the contents of
Annex 6 are available as Amendment 1 to MSN 1792 in a separate Merchant Shipping Notice.
The content remains the same as in LY2 Edition 2.
ANNEX 7
Position
|
Change type
|
Detail
|
Page 1 & 2
|
New cover
|
|
Page 5 para
1.4
|
Editorial change
|
After ‘territories’ added ‘and crown dependencies’.
|
Page 5 para
1.2
|
Editorial change
|
After ‘pleasure’ added ‘such as large yachts,’ and added new section ‘Since its original
publication, the Large Yacht Code has made a significant impression on a maritime
sector which previously found great difficulty in embracing conventional regulation.
As a result the Code enjoys both national support and international recognition as
a standard, breaking new ground both in its inception and methodology.’
|
Page 5 para
1.3
|
Editorial change
|
After ’12 passengers.’ inserted ‘Sail training ships are included in this application.’
|
Page 5 para
1.4
|
Editorial change
|
After ‘Letter No’ inserted ‘2937, dated 13 January 2009.’
|
Page 4
|
Editorial change only
|
Annex 7 – Edition 1 changed to Edition 2.
|
Para 1
|
Editorial change
|
Inserted ‘and crown dependencies’ after ‘territories’.
|
Para 1.3
|
Removes upper limit for tonnage
|
After ‘to vessels’ deleted ‘of less than3000 gross tonnes (GT)’
|
Para 1.4
|
Updates regulation reference
|
‘No. 1996’ changed to ‘No 2937, dated 13 January 2009.’
|
Para 1.6
|
Editorial change only
|
After ‘revised in’ changed 2004 to 2012.
|
Page 9
|
Added definition ‘Design Waterline’
|
Inserted ‘‘Design Waterline’ Deepest loaded draught’.
|
Position
|
Change type
|
Detail
|
Page 10
|
Updates definition for new version of the code.
|
Deleted ‘‘Existing vessel’ means any vessel, the keel of which was laid or the construction
or lay up was started before the 16th December 1998;’ inserted Existing vessel’
means any vessel, the keel of which was laid or was at a similar stage of construction
prior to the 1st October 2013 or the date of entry into force of the Maritime Labour
Convention 2006 if that be sooner.’
|
Page 12
|
New definition added
|
‘Major conversion’ means a conversion of a vessel:
(a) that substantially alters the dimensions of a vessel,
(b) which changes the type of the vessel;
(c) the intent of which in the opinion of the Administration is substantially to prolong
its life;
(d) which otherwise so alters the ship that, if it were a new vessel, it would become
subject to relevant provisions of the present code not applicable to it as an existing
vessel.
|
Page 13
|
Updates definition for new version of the code.
|
Deleted ‘‘New vessel’ means a vessel to which this Code applies, the keel of which
was laid or the construction or lay up was started on or after the 16th December 1998;
inserted ‘‘New vessel’ means a vessel to which this Code applies, the keel of which
was at a similar stage of construction on or after the 1st October 2013 or the date
of entry into force of the Maritime Labour Convention 2006 if that be sooner.’
|
|
Added definition ‘officer’
|
‘Officer’ means
(a) any seafarer who is required to be qualified under the International Convention
on Standards of Training, Certification and Watchkeeping for Seafarers, 1978, as amended
(STCW Convention); or
(b) any other seafarer considered by the owner/managing agent to be an officer.
|
Position
|
Change type
|
Detail
|
Page 15
|
|
Deleted ‘‘Short Range Yacht’ means an existing vessel under 500GT or a new vessel
under 300GT,’
Inserted ‘‘Short Range Yacht’ means a vessel under 500GT the keel of which was laid
or was at a similar stage of construction prior to the 1st August 2005 or a new vessel
constructed on or after that date under 300GT.
|
Page 15
|
Added less onerous limitation for sailing yachts, allowing them to operate in a wider
range of conditions.
|
Bullet point – after Beaufort Force 4 – added – for a motor yacht, and Force 6 for
a sailing yacht.
|
|
Inserted definition of ‘seafarer’
|
‘Seafarer’ means any person who is employed or engaged or works in any capacity on
board a ship. (See National Annex for interpretation).
|
Page 15
|
Added definition ‘Similar stage of construction’
|
‘Similar stage of construction’ means at a stage which
(a) construction identifiable with a specific vessel begins; and
(b) assembly of that vessel, comprising at least 1% of the estimated mass of all structural
material has commenced.
In the case of vessels constructed of FRP or GRP this will be considered as the date
when more than 5% of the hull resin and reinforcement has been laid.
|
Page 15
|
Added definition ‘Submersible craft’
|
‘Submersible Craft’ means any description of manned mobile submersible apparatus which
is designed to maintain some or all of its occupants at or near atmospheric pressure
including free, self-propelled, tethered, towed or bottom contact propelled apparatus
and atmospheric diving suits. A diving bell is not a submersible craft for the purposes
of these Regulations; and ‘diving bell’ means any compression chamber which is capable
of being manned and is used or designed for use under the surface of water in supporting
human life being a chamber in which any occupant is or may be subjected to a pressure
of more than 300 millibars above atmospheric pressure during normal operation.
|
Position
|
Change type
|
Detail
|
Page 18
|
Editorial change only, describes the meaning of tons
|
Added footnote ‘‘tons’ means gross tons, measured in accordance with the Regulations
for measuring tonnage in force on 20th July 1968’.
|
Para 3.1.1
|
|
After ’12 passengers.’ Deleted ‘The code only applies to vessels of less than 3000GT.’
|
Para 3.1.1.1
|
Clarification allowing administration to determine application of the code to yachts
operating under international racing rules. The text proposed allows yachts to comply
with racing rules rather than code standards for officially organised yacht races
allowing them more flexibility.
|
‘The administration may establish alternative standards for yachts operating under
International Sailing Federation (ISAF) or Union Internationale Motonautique (UIM)
racing rules; refer to the National Annex for details’.
|
Para 3.1.3.1
|
Provides guidance on the application of IMO safety and pollution prevention guidance
for vessels operating in the polar regions. All vessels have always been expected
to comply with these standards, more detail is inserted to direct owners and operators
to relevant guidance as operating vessels in polar areas when they not designed to
cope with the rigorous environment is extremely dangerous.
|
After ‘operation’ inserted ‘outside Polar Regions’ inserted new para
3.1.3.2. ‘Yachts which intend to operate in Polar Regions must meet requirements of
one of the recognised Classification Societies listed in the National Annex appropriate
to the intended area of operation. Stability conditions should include those for icing.
Reference to be made to the IMO Guidelines for Polar Regions, Resolution A.1024(26)
as amended or replaced by IMO for yachts intended to operate inside polar regions.
|
Para 3.2.3
|
Change to title
|
Inserted ‘New and ‘ before ‘Existing’
|
Para 3.2.3.4
|
Editorial change – describes implementation of the code but allows older vessels to
continue to comply with previous standards excepting where these require updating.
|
Deleted
‘3.2.3.4 Existing vessels not previously certified under the Code
.1 Vessels whose surveys commenced before 1st June 2006 may be surveyed under LY1.
.2 Existing vessels under 500GT whose surveys commenced on or after 1st June 2006,
should be surveyed under this Code. In such cases where engine room insulation does
not meet the required standard, an alternative arrangement maybe considered for short
range service.
|
Position
|
Change Type
|
Detail
|
|
|
.3 Existing vessels of 500GT and over whose surveys commenced on or after 1st June
2006 but before 1st June 2008 may be certificated under LY1, providing:
(a) a sprinkler system is installed throughout all accommodation and service spaces,
and
(b) an addressable fire detection system is installed throughout all accommodation
and service spaces, and
(c) steps are taken to reduce the spread of smoke in accommodation escape routes.
Inserted
‘Vessels the keels of which were laid or were at a similar stage of construction before
the 1st October 2013 or the date of entry into force of the Maritime Labour Convention
2006 if that be sooner. and which have and have been or are currently under survey
to LY1 or LY2 may continue to be considered under the standards in force at the time
of initial survey with the exception of the following which must comply with this
version of the code:
(a) Section 13.2.7 Lifejackets;
(b) Section 16.3.1 (Radio equipment)
(c) Section 18.1.8 Vessels of 300GT and over have LRIT fitted;
(d) Section 18.1.9 Vessels of 150 GT and over have BNWAS fitted;
(e) Section 26 Manning and Personnel Certification;
(f) Section 29 Crew Agreements
(g) Section 30.2 Vessels under 500GT, Safety Management
(h) Existing sailing yachts may take advantage of the definition of a ‘Short range
yacht’ in this version of the Code
3.2.3.5 All other vessels should be surveyed under this version of the Code.’
|
Para 3.4
|
Clarifies consultation provisions
|
Para 3.4 after committee…. Added ‘Any major revisions will be in consultation with
industry listed at Annex 1.’
|
Position
|
Change Type
|
Detail
|
Para 4 (Box)
|
Yachts already comply but text amended to make requirement to have a ‘commercial yacht’
classification certificate for commercial operation clearer.
|
Deleted ‘New Vessels are to be built to the requirements of one of the recognised
Classification Societies listed in the National Annex and issued with a Class Certificate.
Existing Vessels which are not already Classed should be taken into Class’.
Inserted ‘Vessels are to be built to the requirements of one of the recognised Classification
Societies listed in the National Annex and issued with a commercial Certificate of
Classification. Existing Vessels which do not have a Certificate of Classification
issued by a Classification Society listed in the National Annex should obtain such
a certificate
|
Para 4.1.5
|
Yachts already comply but revision makes this clearer.
|
Added new para ‘Where a considerable risk of lightning strike is identified vessels
should have lightning strike protection.‘
|
Para 4.2.1-4
|
Updates requirements for this version of the code.
|
Deleted ‘For unlimited operation, all vessels must be classed.’ Inserted ‘All vessels
must be constructed in accordance with the requirements of a recognized Classification
Society listed in the National Annex.’
Deleted ‘For operation within the Short Range Yacht Category, all new vessels must
be classed.
and ‘Existing un-classed vessels of less than 500GT may be considered for restricted
operation within the Short Range Category.’ Re numbered paragraphs to suit.
|
Para 4.3.1.2
|
1. Editorial change
2. Existing policy decision which makes compliance easier for yachts which would otherwise
be required to comply with full SOLAS requirement.
|
1. Deleted ‘regulations’ and replaced with ‘Chapter’.
2. Inserted ‘Hand operation from above the bulkhead deck and a hydraulic accumulator
may be omitted if each door has it’s own individual power-pack electrically driven
via the emergency switchboard, and control voltage from emergency battery, and each
door can be operated manually at the door by hand. Edge strips which stop the door
closing on contact are not permitted’.
|
Position
|
Change Type
|
Detail
|
Para 4.4.1
|
Editorial change to clarify paragraph only
|
Para 4.4.1 deleted ‘Compartment(s) below the freeboard deck, provided for recreational
purposes, oil fuelling/fresh water reception or other purposes to do with the business
of the vessel and having access openings in the hull, should be bounded by watertight
divisions without any opening (i.e. doors, manholes, ventilation ducts or any other
opening) separating the compartment(s) from any other compartment below the freeboard
deck, unless provided with sliding watertight doors complying with 4.3.1, or for vessels
under 500GT, hinged doors complying with 4.4.2’ and replaced with ‘Compartment(s)
below the freeboard deck, provided for recreational purposes, oil fuelling/fresh water
reception or other purposes to do with the business of the vessel and having access
openings in the hull, should be bounded by watertight divisions without any opening
(i.e. doors, manholes, ventilation ducts or any other opening) separating the compartment(s)
from any other compartment below the freeboard deck, unless provided with sliding
watertight doors complying with 4.3.1, or for vessels under 500GT, hinged doors complying
with 4.4.2.’.
|
Para 4.4.2.2.(e)
|
Clarifies definition
|
After ‘the’ deleted ‘design’ inserted ‘deepest loaded’.
|
Para 4.4.3
|
Yachts already comply however updated reference to align with SOLAS
|
Changed para 4.4.2 to 4.4.3 and replaced II-1/25-10 to II-1/15-1.
|
Para 4.4.3
|
Updates the code to align with class rules, change also allows unusual arrangements
which do not comply to be specially considered by the administration.
|
Para 4.4.3 added ‘II-1/15-1’ after regulation and added ‘Openings are generally to
be fitted with a sill not less than 600 mm above the design waterline.
4.4.3.1 Openings in the hull with a sill height below, or less than 600 mm above the
design waterline may be specially considered by the Administration. This consideration
may include but is not limited to:
|
Position
|
Change Type
|
Detail
|
|
|
.1 Doors from the space providing internal access are to have a sill height at least
600 mm above the design waterline;
.2 The effect of flooding on stability is considered;
.3 Operational controls and limitations on when and where opening may be used.’
|
Para 4.5
|
Provides clarification on the requirements for the design and installation of sailing
yacht masts and rigging.
|
4.5.1 General
The condition of the rig should be monitored in accordance with a Maintenance Manual
and a planned maintenance schedule. The schedule should include, in particular, regular
monitoring of all the gear associated with safe work aloft and on the bowsprit (see
22.3).
4.5.2 Masts and spars and standing rigging
4.5.2.1 Dimensions and construction materials of masts and spars and dimensions of
standing rigging including connection to chain plates should be in accordance with
the requirements or recommendations of one of the Classification Societies referred
to in 4.3.1.1 or a recognised national or international standard.
4.5.2.2 The associated structure for masts and spars (including chainplates, fittings,
decks and floors) should be constructed to effectively carry and transmit the forces
involved.
4.5.2.3 Compliance with 4.5.2.1 and 4.5.2.2 Should be confirmed by a design review
and approval by one of the Classification Societies (eg Rig Design Certificate) which
is assigned with the review of the rig.
4.5.2.4 The Maintenance Manual provided by the mast manufacturer Should be reviewed
and approved by the Classification Society which is assigned to review the rig design.
|
Position
|
Change Type
|
Detail
|
|
|
4.5.2.5 A physical survey on the rig stepping procedure and the rig behaviour during
sea trials is to be carried out by or on behalf of the Classification Society that
is involved with the classification of the vessel’s hull.
4.5.2.6 Annual surveys on the vessel shall include reviewing records and history of
rig maintenance measures against the specifications provided by the maintenance manual.
4.5.3 Rigging fittings
|
Para 5.2.1.1
|
Editorial change only
|
Para 5.2.1.1 after weather deck deleted ‘.’.
|
Para 5.4.4
|
Text from 5.5.6 moved to this section for clarity.
|
Proposals to fit large portlights (i.e. greater than 0.16 M2) in the main hull below the level of the freeboard deck will be subject to special
consideration and approval by the Administration, having regard for their location
and strength and their supporting structure and, the availability of strong protective
covers for them. One item of the special consideration should be operational instructions
to the Master as to when the strong protective covers must be fitted.
|
Para 5.4.5
|
Text from old para 5.4.4 moved to this point.
|
‘Portlights should not be fitted in the hull in the way of the machinery space.’
|
Para 5.5.6
|
Clarifies rules to be applied to large glass filled openings in the hull.
|
Existing paragraph replaced with ‘Windows should not be fitted in the main hull below
the level of the freeboard deck.
|
Para 5.5.7
|
Provides additional clarification on the meaning of storm shutter.
|
Para 5.5.7 after … ‘storm shutters’ inserted ‘strong protective covers with fittings)’.
|
Para 5.5.7.1
|
No new requirement but clarifies and makes the paragraph easier to understand.
|
Added Para 5.5.7.1 and added ‘((A plate capable of being fixed over a broken window)’
after ‘shutters’; added ‘specified in 5.5.1’ after ‘specified standard’; added ‘For
windows subject to test in accordance with 5.5.2 only blanking plates are required.
‘ at end.
|
Position
|
Change Type
|
Detail
|
Para 5.5.8
|
Editorial change only
|
Para 5.5.8 after polarised inserted ‘or’.
|
Para 5.6.1
|
Yachts already comply but clarifies existing interpretation of code for engine exhausts
passing through passenger and crew cabins and accommodation.
|
5.6.1 added ‘.where machinery exhaust systems pass though accommodation they should
be fitted in a gas tight trunk or each space should be fitted with a carbon monoxide
detector. An alarm is to be provided locally and at a continuously manned station’
|
Para 5.8.2
|
The practice of fitting underwater lights is largely restricted to the yacht industry;
to ensure these lights do not adversely affect the watertight integrity, this addition
requires them to be approved by the classification society.
|
Para 5.8 renumbered paragraph 5.8.1 and added 5.8.2 ‘Underwater lights and associated
penetrations fitted in the hull should be approved by the Classification Society.’
|
Para 5.9.2
|
Editorial change only
|
Para 5.9.2 changed ‘valves’ to ‘piping’.
|
Para 5.9.3
|
Editorial change only, corrects references to other parts of the code.
|
Para 5.9.3 after … Test Procedures Code; …. added … and 14A.2.3.4 or 14B.2.11.6.
|
Para 7A.1.1
|
Editorial change only
|
Para 7A.1.1 deleted ‘regulations’ and replaced with ‘Chapter’.
|
Para 7B.1
|
Editorial change only
|
Para 7B.1 deleted ‘regulations’ and replaced with ‘Chapters’.
|
8A.3
|
Editorial change clarifies and simplifies requirement.
|
After ‘provided with’ changed ‘adequate’ to ‘appropriate’ deleted ‘Reference should
also be made to Section 14.1.5.’
|
8B.1
|
Editorial change only
|
Para 8B.1 deleted ‘regulations’ and replaced with ‘Chapter’.
|
8B.2
|
Existing interpretation of the code inserted for clarity
|
After should be added ‘self contained (independent of a sea water suction) and’
|
8B.3
|
No new requirement but aligns code requirements with SOLAS convention and classification
society rules
|
Inserted para 8B.3. ‘Cables and wiring serving essential or emergency power, lighting,
internal communications or signals shall be routed clear of galleys, machinery spaces
of Category A and their casings, spaces for storage of petrol, and other high risk
fire areas.’
|
9B.1
|
Editorial change only
|
Para 9B.1 deleted ‘regulations’ and replaced with ‘Chapter’.
|
Position
|
Change Type
|
Detail
|
10A.2 &
10A.3
|
No new requirement, clarifies application of code to bilge pumping systems.
|
Para 10A.2 added ‘bilge’ between powered and pumps.
Para 10A.3 Added ‘The location of pumps required by 10A.2, their individual power
supplies and controls, including those for bilge valves should be such that, in the
event of any one compartment being flooded at least one of those pumps is capable
of removing water from the flooded space and adjacent compartments and discharging
this via a dedicated discharge overboard.’
|
10B.1
|
Editorial change only
|
Para 10B deleted ‘regulations’ and replaced with ‘Chapter’.
|
10B
|
Editorial change only
|
Added paragraph numbers to 10B
|
1.2.2.2.2
|
Editorial Change – clarifies text
|
After the deleted ‘design waterline’ and inserted ‘Design Waterline’
|
Para 11.3.4
|
Editorial change only
|
Replaced diagram with text amendments added ‘m’ after 0.1. and amended angles to reflect
text.
|
Para 11.3.5
|
Editorial change only
|
Change ‘Freeboard length’ to ‘Length’ After ‘SOLAS’ Insert ’90 passenger ship’
|
Para 11.5.3
|
Editorial change only
|
After ‘major’ deleted refit and inserted ‘conversion’.
|
Para 13.1.7
|
Changed code to align with SOLAS, removes existing annual servicing requirement for
fully inflated rescue boats.
|
After inflatable deleted ‘boat’ and inserted ‘lifejacket‘, after ‘release unit’ added
‘other than a disposable hydro static release unit’ inserted ‘unless extended service
intervals have been approved by the Administration;’ after ‘at a’ inserted ‘manufacturers
and deleted ‘approved’.
Deleted ‘Hydrostatic release units which have been approved for a service life of
2 years and which should be replaced at the end of their life, need not be serviced
after 1 year.’
|
Position
|
Change Type
|
Detail
|
|
|
Added new para 13.1.8 ‘All repairs and maintenance of permanently inflated rescue
boats should be carried out in accordance with the manufacturers instructions; emergency
repairs may be carried out onboard; however, permanent repairs should be effected
at an approved servicing station.’
Re-numbered remaining paragraphs
|
Para 13.2.1.3
|
Clarification of requirement
|
After ‘provided on Deleted ‘either’ inserted ‘each’.
|
Para 13.2.3.3
|
Change to code requirements to design out dangerous and ineffective launching systems
mounted on the extreme bow of yachts.
|
Inserted ‘13.2.3.3’ Launching stations should be in such positions as to ensure safe
launching having particular regard to clearance from the propeller and steeply overhanging
portions of the hull and so that, as far as possible, the rescue boat can be launched
down the straight side of the ship whilst maintaining minimum speed to keep a course’.
13.2.3.4 If stowed forward the launching appliance and rescue boat should be
entirely located in a sheltered position abaft the vertical extension of the aft most
portion of the collision bulkhead.
|
Para 13.2.3.2.2
|
No additional requirement, editorial change only, clarifies code requirement
|
Para 13.2.3.2 deleted … if stowed in a grab bag … and replaced with … ‘If the equipment
as required is stowed in a grab bag, it may be stowed in the boat or in an easily
accessible location close to the rescue boat.’
|
13.2.4.2
|
Aligns the code with SOLAS convention requirements for life jackets for lager persons
but does not apply minimum permanent carriage requirement.
|
Additional paragraph added to 13.2.4.2 ‘If the adult lifejackets provided are not
designed to fit persons weighing up to 140 kg and with a chest girth of up to 1,750
mm, a sufficient number of suitable accessories as may be required to provide a lifejacket
for each such person shall be available on board to allow them to be secured to such
persons.’
|
13.2.4.4
|
Aligns code with SOLAS requirement but does not apply minimum permanent carriage requirement.
|
Added ‘One SOLAS approved child lifejacket or infant lifejacket should be provided
for each child or infant onboard.
|
Position
|
Change Type
|
Detail
|
13.2.5.1
|
Editorial change – allows carriage of smaller non- insulated immersion suits
|
After ‘onboard’ added ‘these may be of the non insulated type.
|
13.2.5.2
|
Added suits for infants to requirement.
|
After ‘children’ inserted ‘and infants’.
|
Para 13.2.5.3
|
No new requirement but offers increased flexibility for operation purely in warmer
waters.
|
13.2.5.3 Added ‘For cold water areas of operation, the insulated type should be carried.
Reference to Resolution IMO MSC Circular 1046 should be made for assessment of thermal
protection.
|
Para 14.1.5.2
|
Editorial change only.
|
Deleted ‘regulations’ and replaced with ‘Chapter’.
|
Para 14.2.2
|
Changed Heading
|
Deleted ‘Thermal Suite (e.g.’…)
|
Para 14.2.1.1
|
Editorial change only.
|
Para 14.2.1.1 changed ‘The perimeter’ to ‘All boundaries’ and changed ‘boundaries’
to ‘divisions’.
|
Para 14.2.2.1
|
Editorial change only
|
Deleted ‘thermal suite and replaced with ‘steam room’.
|
Para 14.2.2.3
|
Added additional flexibility for steam generators under 5kW
|
After ‘If’ Deleted ‘the ‘ Inserted ‘a’; After ‘Generator’ added new paragraph replaces
old ‘If the steam generator of more than 5 kW is not contained within the perimeter
then the boundaries of the space should be constructed of B-0 class divisions, and
the steam generator should be protected by A-0 standard divisions, or B-0 for Short
Range Yachts and pipes leading to the discharge nozzles should be lagged.’
|
Para 14.2.2.5
|
Deleted requirement for a sprinkler
|
After ‘system’ deleted ‘and an automatic sprinkler.’
|
Para 14.2.3
|
Editorial change only.
|
Inserted ‘in’ before SOLAS.
|
Para 14.3.5
|
Aligns code with SOLAS requirements.
|
Added ‘For yachts over 500GT, a Fire Training Manual, as required by SOLAS II-2/15
should be provided.’
|
Table 14A.1.1
|
Editorial change only
|
Deleted /’A-O’, Added ‘Galleys B-15 (for yachts not being Short Range Yachts)’.
|
Position
|
Change Type
|
Detail
|
Para 14A.2
|
Editorial Change, simplifies text.
|
Para 14.2
Deleted ‘• the ship should be subdivided by thermal and structural boundaries as required
by this section;’
• thermal insulation of boundaries should have due regard to the fire risk’ of the
space and adjacent spaces;
Added ‘• the engine room and galley should be contained within boundaries required
by this section.
|
Para 14A.2.1.3.4
|
Editorial change only.
|
Para 14A.2.1.3.4 changed ‘looses’ to ‘loses’.
|
Para 14A.2.2.1
|
Applies recommendation to enclose galleys for yachts which are not Short in fire rated
boundaries
|
Para 14A.2.2.1 Deleted ‘a) Machinery spaces of category 'A', are to be enclosed by
'A-30' Class divisions.
b) For Short Range Yachts, machinery spaces of category ‘A’ , are to be enclosed by
'B-15' Class divisions.’
Replaced with updated paragraph:
(a) Machinery spaces of category ‘A’, are to be enclosed by ‘A- 30’ Class boundaries.
For Short Range Yachts, such machinery spaces are to be enclosed by ‘B-15’ Class boundaries;
(c) Yachts which are not Short Range Yachts the keels of which are laid or at a similar
stage of construction on or after 1 January 2015 are to have galleys enclosed by ‘B-15’
Boundaries. It is recommended that vessels constructed before this date also comply
with this requirement.’
|
Para 14A.2.2.3
|
Editorial change only
|
Para 14A.2.2.3 changed ‘beamed’ to ‘be made’.
|
Para 14A.2.2.5
|
No new requirement as yachts already expected to comply with this at construction
stage, text updated to avoid confusion.
|
Para 14A.2.2.5 deleted …. (this may be reduced to 380mm on steel divisions only).
|
Position
|
Change Type
|
Detail
|
Para 14A.2.3.1
|
Editorial change only
|
Para 14A.2.3.1 changed ‘fire and comfort’ to ‘thermal and acoustic’.
|
Para 14A.2.3.6
|
Editorial change for easier understanding.
|
After ‘vessel’ inserted ‘including open decks’ After ‘equivalent’ deleted ‘approved’.
|
Para 14A.2.3.7
|
Removes recommendation, only permitting combustion modified furniture and mattresses.
|
Deleted ‘It is recommended that’.
|
Para 14A.2.3.8
|
Editorial change for easier understanding.
|
After ‘equivalent’ deleted ‘approved’.
|
Para 14A.2.5.6
|
Editorial change only
|
deleted ‘,’
|
Para 14A.3.1
|
Editorial change only
|
Spacing added between bullet points.
|
Para 14A.4.2
|
Aligns Code with SOLAS requirement
|
Added ‘.3 fixed means for extinguishing a fire within the galley exhaust duct.’
|
Para 14A.4.3
|
No new requirement, corrects omission from last version of code.
|
Added ‘galleys’ after ‘category ‘A’ machinery spaces’.
|
14A.4.8
|
Adds requirement for lint traps in tumble drier ventilation ducts.
|
‘Ducts provided for tumble driers are to be fitted with suitably located cleaning
and inspection openings.’
|
Para 14A.7.2
|
Adds requirement for fire alarms to be audible externally as well as internally.
|
After … Chapter 9 inserted ‘, and should be audible externally.’
|
Table 14B.2
|
Editorial change only
|
Table 14B.2 changed 14B.2.15 to 14B.2.14.
|
Table 14B.2
|
Editorial change only
|
Inserted table line between Fixed Fire Detection and Fire Extinguishing arrangements.
|
Para 14B.2.5,
Table 2
|
Editorial change only
|
Table 2 – Fire integrity made division between spaces above and inserted ‘spaces below’.
|
Position
|
Change Type
|
Position
|
Para 14B.2.5
Notes to tables
|
Editorial Change only
|
Para b deleted ‘(9)’ inserted ‘(8)’
|
Para 14B.2.7.2
|
No new requirement, corrects omission in last version of code.
|
Inserted ‘Sliding’ before ‘steel’.
|
Para 14B.2.7.5
|
Editorial change only
|
Changed ‘beamed’ to ‘be made’.
|
Para 14B.2.11.2
|
Allows use of combustible insulation for fridges and freezers.
|
Para 14B2.11.2 deleted … The use of combustible materials is to be kept to a minimum.
After ‘non-combustible’ inserted ‘however core insulation of refrigerator and cold
rooms need not be.’ Moved text 14B.2.11.9 to this para and moved other paragraphs
to suit.
|
Para 14B.2.11.9
|
Clarification of existing text
|
After ‘vessel’ inserted ‘and on open decks’.
|
Para 14B.2.12.1.7
|
Editorial change only
|
Changed ‘3,5 m’ to ‘3.5m’.
|
Para 14B.2.13.3
|
Editorial change only
|
After ‘category A’, deleted ‘machinery spaces,’.
|
Para 14B.2.13.4
|
Editorial change only
|
After ‘category A’ deleted ‘machinery spaces,’.
|
Para 14B.2.13.4.5
|
Editorial change only
|
After ‘within a machinery space’ inserted ‘of category A’.
|
Para 14B.2.13.7
|
Requires shutdown to be external to the galley
|
After ‘duct’ added ‘ (if required for the extinguishing medium’. Deleted ‘operable
from within the galley;’ added ‘Local controls to activate extinguishing system; stop
the fans and close the fire dampers should be grouped in one position immediately
outside the main entrance to the galley.’
|
Position
|
Change Type
|
Detail
|
Para 14B.2.13.17
|
Editorial change only
|
Deleted ‘14B.1’ and replaced with ’14.1.5.
|
Para 14B.2.13.17
|
Editorial change only
|
Deleted ’14.2.20’ and replace with 14A.5.
|
Para 14B.2.13.18
|
Clarification of code requirement for measures to trap lint in ventilation ducts.
|
After … ‘ventilation from’ … inserted ‘and tumble driers’.
|
Para 14B.2.14.1
|
Editorial change only
|
After … ‘A-0’ class deleted ‘divisions’.
|
Para 14B.2.14.1
|
Aligns code requirement with IMO fire safety systems code, applies less onerous standard.
|
After … ‘whichever is the greater’ inserted ‘subject to a maximum of 280m2.
|
Para 14B.2.14.2
|
Editorial change, moves text to new paragraph for clarity
|
Deleted ‘In addition, a fixed ..... within accommodation spaces;’
|
Para 14B.2.14.2
|
Editorial change, moves text to new paragraph for clarity, adds requirement for alarm
to be audible externally.
|
Inserted new para 14B.2.14.2. ‘A fixed fire detection and fire alarm system is to
be fitted in all enclosed spaces except those containing no significant fire risk
(toilets, bathrooms, void spaces, etc). Manually operated call points shall be placed
to ensure a readily accessible means of notification. The fixed fire detection and
fire-alarm system is to be installed in accordance with the requirements of SOLAS
II-2/7 and the IMO Fire Safety Systems Code, Chapter 9, and should be audible externally.
|
Para 14B.2.15.1
|
No new requirement, editorial change only
|
For vessels having a length of 85 m or more, a public address system complying with
the requirements of SOLAS 74'. Chapter III, regulation 6.5 is to be available throughout
the accommodation and service spaces and control stations and open decks
|
Para 15A.1 Table 1
|
Editorial change only
|
15A Table 1 – FIRE APPLIANCES item 7 deleted ‘containing internal combustion type
machinery’ and replaced with ‘of Category A’.
|
Position
|
Change Type
|
Detail
|
Para 15A.1 Table 1
|
No new requirement but clarifies text
|
15A Table 1 – FIRE APPLICANCES item 8 after ‘… apparatus’ inserted ‘for each outfit’
and deleted 1
|
Para 15A.1
|
Editorial change
|
Deleted notes at end of page.
|
Para 15A.2.3.5
|
Editorial change
|
Added ‘permanent’ after ‘no’
|
Para 15A.2.4.1
|
Allows use of standard fire hoses which are cheaper and easier to obtain.
|
Deleted ‘18’ Inserted ‘20’ Deleted ‘45mm’ inserted ‘38mm’
|
Para 15A.2.5.1
|
No new requirement, clarifies minimum requirement
|
Para 15A.2.5.1 after ‘… should be of an approved’ inserted ‘5kg/ 9 litre’.
|
15B
|
Editorial change only
|
Removed bold from text.
|
16
|
New section, aligns the code with requirements of the Cayman Islands and SOLAS Global
Marine Distress and Safety System (GMDSS)
|
Inserted new Section 16 on Radio communications.
|
Para 17.3
|
Clarifies code requirements for navigation lights for compliance with Convention on
collision regulations.
|
After ‘spare’ deleted ‘Lamp and inserted ‘bulb’ after ‘…within three minutes.’ Added
‘However, on yachts over 500GT these must be duplicate lights.’
|
Para 18.1.2.3
|
Editorial correction, changed wording to match SOLAS, provides input data for other
navigation equipment
|
Deleted ‘Distance measuring log’ Added ‘speed and distance measuring device, or other
means, to indicate speed and distance through the water’.
|
Para 18.1.8
|
Yachts already comply with SOLAS requirements
|
Inserted new para 18.1.8 (LRIT).
|
Para 18.1.9
|
Yachts required to fit Bridge Navigational Watch Alarm Systems in accordance with
SOLAS requirements
|
Inserted new para 18.1.9.
|
Para 18.1.10
|
New paragraph, permits inclusion of vessels over 3000GT who already comply with this
requirement.
|
Added ‘18.1.10 Vessels of 3000 GT and over should comply with the requirements of
SOLAS Chapter V’.
|
Position
|
Change Type
|
Detail
|
Para 19.1
|
Adds notice related to STCW convention for training in use of Electronic Chart Display
Information Systems
|
After ‘duplicate ECDIS’ Inserted ‘Where duplicate ECDIS is provided as the primary
means of navigation, officers with responsibility for navigation watch keeping should
have received appropriate shore based and ship type-specific training.’
|
Para 21.1.1
|
Editorial Change to accommodate new sections for substantial equivalence.
|
Inserted ‘This section applies to vessels to which sections 21A and 21B do not apply.’
|
Para 21.1.2
|
No new requirement, clarifies need to consider accommodation for hotel staff in addition
to officers.
|
After ‘on board’ added ‘due consideration should also be given to the number of hotel
staff required.’
|
Para 21.9.1
|
No new requirement, states minimum bunk size required
|
Added ‘minimum inside dimensions 1.98m x 0.80m’.
|
Para 21.1.2
|
Reminds designers that hotel staff requirements should be incorporated into consideration
for design of accommodation.
|
After ‘board,’ inserted due consideration should also be given to the number of hotel
staff required.’
|
Para 21.9.1
|
Changed bunk size requirement to align with new sections 21A & B
|
After cot added’,) should be provided for every person on board, having a minimum
inside dimension of either:
.1not less than 190 centimetres by 70 centimetres, with no tapering, where it is satisfied
that that this is reasonable and will not result in discomfort to the seafarers; or
.2 not less than 198 centimetres in length and not less than 80 centimetres in width
over half the length of the berth. A taper is permitted from half the length of the
berth towards the foot of the berth but under no circumstances is the berth permitted
to be narrower than 50 centimetres.
3. Where considered appropriate, means for preventing the occupants from falling out,
should be provided.
|
Position
|
Change Type
|
Detail
|
Para 21A & B
|
Notifies industry of intention to update code to align with ILO Maritime Labour Convention
|
Inserted new para 21A & B.
|
Para 22.3.2.3
|
Updates code to refer to latest guidance
|
Para 22.3.2.3 Inserted ‘(Refer to national Annex)’ after ‘overside’.
|
Para 22.6
|
Adds requirements for passenger and crew lifts to the code
|
Para 22.6 Inserted new standards on lifts.
|
Para 24.2.1.3
|
No change to requirements, guidance added for clarity, the fire suits for the helideck
crew should meet this standard for rescue purposes.
|
Added ‘Fire suits provided for helideck crew should be of EN 469 standard’.
|
Para 24.2.6
|
Links code to guidance formulated by the ‘Large Yacht Helideck Working Group’ – a
working group bringing together MCA, and industry to provide yacht specific guidance
for helicopter operations.
|
Deleted ‘Ship to shore and ship to helicopter communications procedures, ship operating
procedures, and guidance on helicopter emergencies are outlined in the International
Chamber of Shipping Guide to Helicopter / Ship Operations and should be used as part
of the operational procedures of the vessel.’
Inserted ‘Ship to shore and ship to helicopter communications procedures, ship operating
procedures, and guidance on helicopter emergencies are outlined in the ‘Large Yacht
Helicopter Operations Handbook’ and ‘Large Yacht Helicopter Refuelling Handbook’ published
by the MCA, these should be used as part of the operational procedures of the vessel,
and equipment carried should permit crew to comply with the onboard procedures.’
|
Para 24.2.7
|
Aligns code best practice agreed with industry operators
|
Added ‘Refuelling of the helicopter while engines and rotors are running is prohibited.’
|
Para 24.5
|
No new requirement, draws attention to existing regulations applicable to submersible
craft.
|
Para 24.5 Inserted new paragraph on Submersible Craft.
|
Para 25.4
|
Aligns the code with MARPOL convention.
|
Inserted new para 25.4. ‘All yachts should comply with the hull Anti- Fouling System
Convention requirements, see national annex’.
|
Position
|
Change Type
|
Detail
|
Para 26.1
|
Editorial change only
|
Removed ‘1’ before ‘hours of work’.
|
Para 26.1.1
|
Removes requirement for certificated Yacht Ratings to be carried.
|
After ‘Engineer Officers’ Deleted ‘together with a sufficient number of qualified
Yacht Ratings’
|
Para 26.1.2
|
Deleted definition as it is included in the main section ‘definitions’
|
Deleted ‘The term ‘seafarer’, is defined as a person employed or engaged in any capacity
on the vessel and should be taken to mean any person employed either directly by a
owner/operator or through a manning agency, whose usual place of work is on the vessel
and includes the master, officers, crew members, and catering, salon and hotel staff.’
|
Para 26.1.7
|
Additional guidance on exceptions to hours of work and rest from STCW convention inserted
|
After ‘crew members’ inserted ‘and designated person ashore (if applicable)’; After
‘compromised’ inserted ‘Exceptions from the weekly rest period provided for in paragraph
26.1.6 should not be allowed for more than two consecutive weeks. The intervals between
two periods of exceptions on board should not be less than twice the duration of the
exception.’
|
Para 26.2.2.5
|
Added additional text reminding designers that the number of personnel required by
the owner to be carried should be taken into account when designing crew accommodation.
|
Inserted ‘Due consideration should also be given to the number of hotel staff required.’
|
Para 26.2.4
|
No new requirement, clarifies need to consider accommodation for hotel staff in addition
to officers.
|
Deleted ‘The tables in Sections 26.2.8 and 26.2.9 provide guidance on the numbers
of certificated deck and engineer officers, and ratings that may be considered appropriate
to different sizes of vessels and tonnages, ‘ After ‘normal operational conditions
added ‘due consideration should also be given to the number of hotel staff required.’
|
26.2.2
|
Additional guidance requiring numbers of hotel staff required to maintain a service
to be considered
|
After ‘conditions’ inserted ‘. Due consideration should also be given to the number
of hotel staff required’.
|
26.2.5
|
Removes duplicated information, now refers to M Notice only
|
After 2nd ‘Manning Document’ deleted ‘in accordance with the tables at Section 26.2.8
and 26.2.9’.
|
Position
|
Change Type
|
Detail
|
26.2.7
|
Removes duplicated information, now refers to M Notice only
|
After ‘Engaged’ inserted ‘See national Annex’.
Deleted ‘This section includes indicative manning levels for vessels of 24 metres
or more in Load Line length. The owner/operators of vessels of vessels below 500GT
or those above 500GT solely engaged for pleasure may find it advantageous to hold
a Safe Manning Document.
In addition to the tables specific submissions may be considered from owners and operators
of vessels, including those less than 500GT, seeking a varied Safe Manning Document
based on a range and risk approach to safe manning with the flexibility to reduce
the manning level taking into account, for example a limiting operating area(s) or
parameters, and levels of automation.’
|
26.2.8 – 26.2.10
|
Deleted text, removing requirement for yacht ratings, other requirements are as per
national annex.
|
Deleted MANNING SCALE FOR MOTOR YACHTS
For details of certificates accepted by the Administration, see National Annex.
[Deleted table]
MANNING SCALE FOR SAILING YACHTS
For details of certificates accepted by the Administration, see National Annex.
[Deleted table] Dual Certification
Where appropriate, dual deck and engineer roles may be considered, provided that the
officer is suitably qualified in both disciplines and that the person holding the
dual role is a person other than the master.
In considering whether a dual role position is appropriate, regard should be had to
the overall safe manning level of the vessel. In such cases additional rating(s) may
be required to be carried.
|
Position
|
Change Type
|
Detail
|
26.2.9
|
Yachts have to comply with the rules of the state in whose waters they operate craft
such as jet-skis, a note to this effect has been inserted. This is of particular relevance
in areas of the Mediterranean, compliance is not optional.
|
Added ‘Personal Water Craft
The operators are reminded that operation of personal watercraft should comply with
the applicable legislation of the state in whose waters they are being operated.’
|
Para 28.1.3
|
Editorial change only
|
Deleted ‘e’ at the end of Annex.
|
Para 28.2.11-
14
|
Summarises updates to international conventions applicable to yachts.
|
Para 28.2 updated para nos 1-13.
|
Para 28.2.9
|
Editorial change only
|
Inserted ‘Certificate’ after ‘Management’.
|
Para 28.2.12
|
Aligns the code with MARPOL convention
|
Inserted, and/or Engine … output greater than 130kw).
|
Para 28.3
|
Editorial change only
|
After ‘level of safety’ deleted ‘The Administration may issue an exemption if and
when appropriate’ inserted ‘The Administration may consider and agree the application.’
|
Para 28.7
|
Editorial change only
|
After ‘All’ inserted ‘ very‘ Third para inserted space after (IMO).
|
Para 29A
|
Provides notice of change of Crew Agreements when new maritime labour Convention comes
into force.
|
Para 29A and 29B added containing equivalent measures for yachts to Maritime Labour
Convention 2006 full requirements.
|
Para 30.3
|
Provides equivalent measure to towing plan required by SOLAS.
|
New para 30.3. All vessels to include emergency towing procedures, as required by
SOLAS regulation II-1/3-4, in their safety management system or in a separate plan.
|
Para 31
|
Editorial change only
|
Para 31 deleted ‘Security and Port Safety Code’ and replaced with ‘Ship and Port Facility
Security Code’.
|
Annex 1
|
Editorial change only
|
Annex 1updated list of working group members.
|
Position
|
Change Type
|
Detail
|
Annex 2
|
Adds emergency towing arrangement and use of personal watercraft to MINI ISM system
|
At section 11 after conduct of passengers and crew while on board; added ‘• emergency
towing (may be in a separate document); • safe use and qualification of users for
personal watercraft.’
|
Annex 4
|
Summarises updates to international conventions applicable to yachts and certification
required.
|
Deleted existing Annex 4 table and replaced with updated version.
|
Annex 5, 2
|
Permits any organisation approved by the MCA to act on it’s behalf as an Aviation
Inspection Body rather than a single body as happened pre
\viously.
|
After ‘Aviation Inspection Body for United Kingdom Vessels Deleted
‘is the Helideck Certification Agency (HCA). Contact details for
HCA are below:-
Helideck Certification Agency
Riverview Business Centre,
Centurion Court,
North Esplanade West,
Aberdeen,
United Kingdom,
AB11 5QH
Tel: +44 (0)1224 289 729
E: info@helidecks.org
W: www.helidecks.org'
Inserted ‘see Ensign website for a current list of current approved
bodies.’
|
Annex 5, 2
|
Editorial change only – aligns with other UK legislation
|
Replaced ‘husband and wife’ with ‘spouse or civil partner’.
|
Position
|
Change Type
|
Detail
|
Annex 5,2
|
Inserts national definition of seafarer, allowing more flexibility for sail training
vessels.
|
Inserted definition ‘‘Seafarer’ means any person, including the master, who is employed
or engaged or works in any capacity on board a ship on the business of the ship but
does not include a person who -
(c) is training in a sail training vessel, or
(d) is onboard a sail training vessel other than for training but -
(i) [is not engaged in or responsible for the navigation of the vessels, and]
(ii) has no emergency safety responsibilities on the vessel.’
|
Annex 5,
3.1.1
|
Editorial change
Removes limitation on tonnage
|
Inserted new application date
Deleted last paragraph ‘The application of the 3000GT limit is not applicable to vessels
for which the building contract is signed, or survey has started, prior to 24th September
2004.’
|
Annex 5
3.1.1.1
|
Added UK interpretation relating to yachts operating under racing rules – allows more
flexibility to yachts operating in officially organised races
|
Added new paragraph 3.1.1.1.
|
Annex 5 Para
3.2.2
|
Paragraph deleted to be replaced with Red Ensign Group common guidance.
|
-
|
Annex 5 Para
4.3.1
|
Added additional classification society to list providing more choice in provision
|
Added ‘Nippon Kaiji Kyokai’.
|
Annex 5 para 14A.2.3.8 &
14B.2.11.12
|
Added guidance on compliance with these paragraphs
|
‘See MGN 453 – FIRE PROTECTION – Fire Retardant Treatment Treatment for Floor Coverings,
Suspended Textile Materials, Upholstery Materials and Bedding Components for use Onboard
Vessels Certified Under the MCA Large Commercial Yacht Code’
|
Annex 5 Para
22.3.2.3
|
Added guidance on UK standards
|
Added ‘Refer to MGN 422’.
|
Position
|
Change Type
|
Detail
|
Annex 5 Para
25
|
Editorial change only – provides guidance o MARPOL convention requirements for Anti-fouling
paints.
|
Updated regulatory references.
|
Annex 5 Para
26.2.4
|
Added guidance for manning on yachts over 3000GT.
Deleted reference to MGN 270 which will remove requirement for ‘Yacht Ratings’ offering
less complex manning to industry.
|
Inserted ‘Vessels over 3000 GT should comply with MSN 1767.’ Deleted ‘MGN 270 ‘’Training
and Certification Guidance – Part 23 – Yacht Rating Certificates for service on commercially
and privately operated yachts and sail training vessels’’.
Inserted ‘Vessels over 3000 GT should comply with MSN 1767.’
|
Annex 5 Para
28.1.2
|
Updated to align with existing policy – offers more flexibility in radio survey arrangements
for UK vessels.
|
Inserted new paragraph ‘The list of UK Certifying Authorities for radio installations
is listed in MGN 392. For classed vessels, radio survey is delegated to classification
societies.
|
Annex 5 Para
28.7
|
Editorial change only update to regulatory reference for accident reporting requirements.
|
Updates regulatory reference ‘Under ‘The Merchant Shipping (Accident Reporting and
Investigation) Regulations’ 2005, SI No. 881, it is a requirement to report accidents
and hazardous events to the Department for Transport’s Marine Accident Investigation
Branch. Guidance is available in MGN 289 ‘Accident Reporting and Investigation’.’
|
Table 1 – List of certificates
|
Editorial change only – updates list in line with MARPOL, MLC convention annexes now
in force with which yachts must comply.
|
Table 1 – replaced with updated table.
|
Annex 6
|
Editorial change only – content of annex will be available electronically to reduce
printing costs and size of published code.
|
Removed from Code and replaced with Annex 6 – new para.
|
Annex 7
|
List of changes updated
|
|